NextSDS Logo
Po

Power Cleaner - 500 ml

DANGER Arosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Power Cleaner - 500 ml
Product Code
25101

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
J140-A0EW-G003-XPCG

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
PC24 Lubrifiants, graisses et agents de dcoffrage; PROC7 Pulvrisation dans des installations industrielles

Overview

Power Cleaner - 500 ml commonly used pc24 lubrifiants, graisses et agents de dcoffrage; proc7 pulvrisation dans des installations industrielles.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Aquatic Chronic Category 2 H411
Skin Irr. Category 2 H315
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur.
  • H229: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur.
  • H315: Provoque une irritation cutane.
  • H319: Provoque une svre irritation des yeux.
  • H336: Peut provoquer somnolence ou vertiges.
  • H411: Toxique pour les organismes aquatiques, entrane des effets nfastes long terme.

Precautionary Statements

  • P210: Tenir l'cart de la chaleur, des surfaces chaudes, des tincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P251: Ne pas perforer, ni brler, mme aprs usage.
  • P305+P351+P338: EN CAS DE CONTACT AVEC LES YEUX: Rincer avec prcaution l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent tre facilement enleves. Continuer rincer.
  • P332+P313: En cas d'irritation cutane: consulter un mdecin.
  • P362+P364: Enlever les vtements contamins et les laver avant rutilisation.
  • P410+P412: Protger du rayonnement solaire. Ne pas exposer une temprature suprieure 50 C/122 F.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PROMANTE sa

manufacturer

📍

Gruuss-Strooss 53/A17 L-9991 Weiswampach

🌍

LU

MCS Belgium bv

distributor

📍

Langerode 16 B-3460 Bekkevoort

🌍

BE

📞

+32 (0)16 47 37 00

Ex & Tric bv

distributor

📍

Spoorwegstraat 1 B-8854 Sint-Denijs

🌍

BE

📞

+32 (0)56 20 69 50

Promant LUX s.a.r.l.

distributor

📍

11, route de Mondorf L-5441 Remerschen

🌍

LU

📞

00352 / 26 38 37 31

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Antipoisons

📞

(+32) 070 245 245

🌍

BE

🕒

24h/j, 7j/sem

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mélange des substances mentionnées la suite avec des additifs non dangereux.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
actone N/A 20-30% ⚠️ Hazardous
naphta hydrotrait bas point d'bullition N/A 25-30% ⚠️ Hazardous
butane N/A 15-25% ⚠️ Hazardous
propane N/A Not specified ⚠️ Hazardous

Composition Notes

Pour le libellé des phrases de risque citées, se référer au chapitre 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

En cas d'inconscience, coucher et transporter la personne en position latrale stable.

🖐️ Skin Contact

Laver immdiatement l'eau et au savon et bien rincer.

👁️ Eye Contact

Rincer les yeux, pendant plusieurs minutes, sous l'eau courante en cartant bien les paupires. Si les troubles persistent, consulter un mdecin.

🍽️ Ingestion/Swallowing

Si les troubles persistent, consulter un mdecin.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Arosol
Critical Property
📊 Physical State Data
aerosol
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Selon dsignation produit
📊 Colour Intensity
Not available
📊 Form
Arosol
👃 Odor
Caractristique
📊 Odor Threshold
Non dtermin.
🧪 Ph
Non dtermin.
🧊 Melting Point
Non dtermin.
Critical Property
💨 Boiling Point
-140 C
Critical Property
🔥 Flash Point
-18 C
Critical Property
📊 Freezing Point
Non dtermin.
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Non applicable.
💨 Vapor Pressure
Non dtermin.
📊 Vapor Density
Non dtermin.
📊 Relative Density
Non dtermin.
📊 Bulk Density
Not available
⚖️ Density
Non dtermine.
Critical Property
🔥 Flammability
Non applicable.
📊 Upper Explosive Limit
13 Vol %
📊 Lower Explosive Limit
3 Vol %
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Le produit ne s'enflamme pas spontanment.
📊 Decomposition Temperature
Non dtermin.
💧 Solubility
Not available
📊 Partition Coefficient
Non dtermin.
📊 Solubility In Water
Pas ou peu miscible
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
65105 %
📊 Metal Corrosion
nant
📊 Dynamic Viscosity
Non dtermin.
📊 Kinematic Viscosity
Non dtermin.
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Sans autre indication, voir point 7.

🧤 Hand Protection

Gants de protection Le matériau des gants doit être imperméable et résistant au produit / à la substance / à la préparation. À cause du manque de tests, aucune recommandation pour un matériau de gants pour le produit / la préparation / le mélange de produits chimiques ne peut être donnée. Choix du matériau des gants en fonction des temps de pénétration, du taux de perméabilité et de la dégradation. Matériau des gants Le choix de gants appropriés dépend non seulement du matériau, mais aussi d'autres critères de qualité qui peuvent varier d'un fabricant à l'autre. Puisque le produit représente une préparation composée de plusieurs substances, la résistance des matériaux des gants ne peut pas être calculée à l'avance et doit, alors, être contrôlée avant l'utilisation. Temps de pénétration du matériau des gants Le temps de pénétration exact est à déterminer par le fabricant des gants de protection et à respecter.

👁️ Eye Protection

Lunettes de protection Lunettes de protection hermétiques

😷 Respiratory Protection

N'est pas nécessaire.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

📦 Proper Shipping Name

AROSOLS, DANGEREUX POUR L'ENVIRONNEMENT

⚠️ Transport Hazard Class

2.1

📋 Packing Group

nant

🚛 ADR Transport Precautions

Attention: Gaz.

🚢 IMDG Maritime Transport Precautions

Attention: Gaz.

✈️ IATA Air Transport Precautions

Attention: Gaz.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Power Cleaner - 500 ml?

The signal word for this substance is "danger".

What is the physical form of Power Cleaner - 500 ml?

Power Cleaner - 500 ml is a arosol with selon dsignation produit color. It has caractristique odor.

What is Power Cleaner - 500 ml used for?

PC24 Lubrifiants, graisses et agents de dcoffrage; PROC7 Pulvrisation dans des installations industrielles

What are the hazard statements for Power Cleaner - 500 ml?

This substance has 6 hazard statements: H222: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur. H229: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur. H315: Provoque une irritation cutane. H319: Provoque une svre irritation des yeux. H336: Peut provoquer somnolence ou vertiges. H411: Toxique pour les organismes aquatiques, entrane des effets nfastes long terme.

What is the melting point of Power Cleaner - 500 ml?

The melting point is Non dtermin. and the boiling point is -140 C.