Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Unique Formula Identifier - for poison centres and emergency response
Uses Information
Overview
Power Cleaner - 500 ml commonly used pc24 lubrifiants, graisses et agents de dcoffrage; proc7 pulvrisation dans des installations industrielles.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS09
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H222: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur.
- H229: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur.
- H315: Provoque une irritation cutane.
- H319: Provoque une svre irritation des yeux.
- H336: Peut provoquer somnolence ou vertiges.
- H411: Toxique pour les organismes aquatiques, entrane des effets nfastes long terme.
Precautionary Statements
- P210: Tenir l'cart de la chaleur, des surfaces chaudes, des tincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
- P251: Ne pas perforer, ni brler, mme aprs usage.
- P305+P351+P338: EN CAS DE CONTACT AVEC LES YEUX: Rincer avec prcaution l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent tre facilement enleves. Continuer rincer.
- P332+P313: En cas d'irritation cutane: consulter un mdecin.
- P362+P364: Enlever les vtements contamins et les laver avant rutilisation.
- P410+P412: Protger du rayonnement solaire. Ne pas exposer une temprature suprieure 50 C/122 F.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
PROMANTE sa
manufacturer
Gruuss-Strooss 53/A17 L-9991 Weiswampach
LU
MCS Belgium bv
distributor
Langerode 16 B-3460 Bekkevoort
BE
+32 (0)16 47 37 00
Ex & Tric bv
distributor
Spoorwegstraat 1 B-8854 Sint-Denijs
BE
+32 (0)56 20 69 50
Promant LUX s.a.r.l.
distributor
11, route de Mondorf L-5441 Remerschen
LU
00352 / 26 38 37 31
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Centre Antipoisons
(+32) 070 245 245
BE
24h/j, 7j/sem
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Mélange des substances mentionnées la suite avec des additifs non dangereux.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| actone | N/A | 20-30% | ⚠️ Hazardous |
| naphta hydrotrait bas point d'bullition | N/A | 25-30% | ⚠️ Hazardous |
| butane | N/A | 15-25% | ⚠️ Hazardous |
| propane | N/A | Not specified | ⚠️ Hazardous |
Composition Notes
Pour le libellé des phrases de risque citées, se référer au chapitre 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
🫁 Inhalation Exposure
En cas d'inconscience, coucher et transporter la personne en position latrale stable.
🖐️ Skin Contact
Laver immdiatement l'eau et au savon et bien rincer.
👁️ Eye Contact
Rincer les yeux, pendant plusieurs minutes, sous l'eau courante en cartant bien les paupires. Si les troubles persistent, consulter un mdecin.
🍽️ Ingestion/Swallowing
Si les troubles persistent, consulter un mdecin.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
🏭 Engineering Controls
Sans autre indication, voir point 7.
🧤 Hand Protection
Gants de protection Le matériau des gants doit être imperméable et résistant au produit / à la substance / à la préparation. À cause du manque de tests, aucune recommandation pour un matériau de gants pour le produit / la préparation / le mélange de produits chimiques ne peut être donnée. Choix du matériau des gants en fonction des temps de pénétration, du taux de perméabilité et de la dégradation. Matériau des gants Le choix de gants appropriés dépend non seulement du matériau, mais aussi d'autres critères de qualité qui peuvent varier d'un fabricant à l'autre. Puisque le produit représente une préparation composée de plusieurs substances, la résistance des matériaux des gants ne peut pas être calculée à l'avance et doit, alors, être contrôlée avant l'utilisation. Temps de pénétration du matériau des gants Le temps de pénétration exact est à déterminer par le fabricant des gants de protection et à respecter.
👁️ Eye Protection
Lunettes de protection Lunettes de protection hermétiques
😷 Respiratory Protection
N'est pas nécessaire.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
🏷️ UN Number
UN1950
📦 Proper Shipping Name
AROSOLS, DANGEREUX POUR L'ENVIRONNEMENT
⚠️ Transport Hazard Class
2.1
📋 Packing Group
nant
🚛 ADR Transport Precautions
Attention: Gaz.
🚢 IMDG Maritime Transport Precautions
Attention: Gaz.
✈️ IATA Air Transport Precautions
Attention: Gaz.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Power Cleaner - 500 ml?
The signal word for this substance is "danger".
What is the physical form of Power Cleaner - 500 ml?
Power Cleaner - 500 ml is a arosol with selon dsignation produit color. It has caractristique odor.
What is Power Cleaner - 500 ml used for?
PC24 Lubrifiants, graisses et agents de dcoffrage; PROC7 Pulvrisation dans des installations industrielles
What are the hazard statements for Power Cleaner - 500 ml?
This substance has 6 hazard statements: H222: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur. H229: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur. H315: Provoque une irritation cutane. H319: Provoque une svre irritation des yeux. H336: Peut provoquer somnolence ou vertiges. H411: Toxique pour les organismes aquatiques, entrane des effets nfastes long terme.
What is the melting point of Power Cleaner - 500 ml?
The melting point is Non dtermin. and the boiling point is -140 C.