NextSDS Logo
Su

Sure Clean - 500 ml

DANGER Aérosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Sure Clean - 500 ml
Product Code
25250

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
1G40-U0VW-000K-7D8T

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
PROC7 Pulvérisation dans des installations industrielles

Overview

Sure Clean - 500 ml commonly used proc7 pulvérisation dans des installations industrielles.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Skin Irrit. Category 2 H315
STOT SE Category 3 H336
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Aérosol extrêmement inflammable.
  • H229: Récipient sous pression: peut éclater sous l’effet de la chaleur.
  • H315: Provoque une irritation cutanée.
  • H336: Peut provoquer somnolence ou vertiges.
  • H412: Nocif pour les organismes aquatiques, entraîne des effets néfastes à long terme.

Precautionary Statements

  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P251: Ne pas perforer, ni brûler, même après usage.
  • P273: Éviter le rejet dans l'environnement.
  • P312: Appeler un CENTRE ANTIPOISON/un médecin en cas de malaise.
  • P403 + P233: Stocker dans un endroit bien ventilé. Maintenir le récipient fermé de manière étanche.
  • P410 + P412: Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50 °C/122 °F.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PROMANTE sa

manufacturer

📍

Gruuss-Strooss 53/A17 L-9991 Weiswampach

🌍

LU

MCS Belgium bv

distributor

📍

Langerode 16 B-3460 Bekkevoort

🌍

BE

📞

+32 (0)16 47 37 00

Ex & Tric bv

distributor

📍

Spoorwegstraat 1 B-8854 Sint-Denijs

🌍

BE

📞

+32 (0)56 20 69 50

Promanté LUX s.a.r.l.

distributor

📍

11, route de Mondorf L-5441 Remerschen

🌍

LU

📞

00352 / 26 38 37 31

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Antipoisons

📞

(+32) 070 245 245

🌍

BE

🕒

24h/j, 7j/sem

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mélange des substances mentionnées à la suite avec des additifs non dangereux.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons C9-C10,n-alkanes,iso-alkanes,cyclics,<2% aromatics
EC: 927-241-2
N/A 30% ⚠️ Hazardous
propane N/A 15-30% ⚠️ Hazardous
butane N/A 5-15% ⚠️ Hazardous

Composition Notes

Pour le libellé des phrases de risque citées, se référer au chapitre 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

En cas d'inconscience, coucher et transporter la personne en position latérale stable.

🖐️ Skin Contact

Laver immédiatement à l'eau et au savon et bien rincer.

👁️ Eye Contact

Rincer les yeux, sous l'eau courante, pendant plusieurs minutes, en écartant bien les paupières.

🍽️ Ingestion/Swallowing

Si les troubles persistent, consulter un médecin.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Relative Density
Non déterminée.
📊 Odor Threshold
Non déterminé.
📊 Voc Content
20–45 %
📊 Form
Aérosol
📊 Molecular Weight
Not available
🔥 Flammability
Non applicable.
📊 Dynamic Viscosity
Non déterminé.
🧪 Ph
Non déterminé.
🧪 Physical State
Aérosol
Critical Property
📊 Relative Evaporation Rate
Not available
📊 Solidification Point
Not available
📊 Solubility In Fat
Not available
💨 Boiling Point
-140 °C
Critical Property
👃 Odor
Caractéristique
📊 Explosive Limits
Not available
📊 Decomposition Temperature
Non déterminé.
🎨 Colour
Selon désignation produit
💨 Evaporation Rate
Non applicable.
📊 Metal Corrosion
néant
💨 Vapor Pressure
8.300 hPa (propane)
👁️ Appearance
Not available
📊 Auto Ignition Temperature
365 °C (butane)
📊 Upper Explosive Limit
10,9 Vol % (propane)
📊 Physical State Data
aerosol
⚖️ Density
Non déterminée.
Critical Property
📊 Vapor Density
Non déterminé.
📊 Bulk Density
Not available
📊 Freezing Point
Non déterminé.
💧 Solubility
Not available
🔥 Flash Point
-18 °C
Critical Property
📊 State Under Standard Conditions
Not available
📊 Lower Explosive Limit
1,5 Vol % (butane)
📊 Cloud Point
Not available
🧊 Melting Point
Non déterminé.
Critical Property
📊 Solubility In Water
Entièrement miscible
📊 Crystallisation Point
Not available
📊 Properties Status
Not available
📊 Partition Coefficient
Non déterminé.
📊 Softening Point
Not available
📊 Colour Intensity
Not available
📊 Kinematic Viscosity
Non déterminé.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Sans autre indication, voir point 7.

🧤 Hand Protection

Gants de protection Le matériau des gants doit être imperméable et résistant au produit / à la substance / à la préparation. À cause du manque de tests, aucune recommandation pour un matériau de gants pour le produit / la préparation / le mélange de produits chimiques ne peut être donnée. Choix du matériau des gants en fonction des temps de pénétration, du taux de perméabilité et de la dégradation. Le choix de gants appropriés dépend non seulement du matériau, mais aussi d'autres critères de qualité qui peuvent varier d'un fabricant à l'autre. Puisque le produit représente une préparation composée de plusieurs substances, la résistance des matériaux des gants ne peut pas être calculée à l'avance et doit, alors, être contrôlée avant l'utilisation. Le temps de pénétration exact est à déterminer par le fabricant des gants de protection et à respecter.

👁️ Eye Protection

Pas nécessaire.

😷 Respiratory Protection

N'est pas nécessaire.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

📦 Proper Shipping Name

AÉROSOLS

📋 Packing Group

néant

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Sure Clean - 500 ml?

The signal word for this substance is "danger".

What is the physical form of Sure Clean - 500 ml?

Sure Clean - 500 ml is a aérosol with selon désignation produit color. It has caractéristique odor.

What is Sure Clean - 500 ml used for?

PROC7 Pulvérisation dans des installations industrielles

What are the hazard statements for Sure Clean - 500 ml?

This substance has 5 hazard statements: H222: Aérosol extrêmement inflammable. H229: Récipient sous pression: peut éclater sous l’effet de la chaleur. H315: Provoque une irritation cutanée. H336: Peut provoquer somnolence ou vertiges. H412: Nocif pour les organismes aquatiques, entraîne des effets néfastes à long terme.

What is the melting point of Sure Clean - 500 ml?

The melting point is Non déterminé. and the boiling point is -140 °C.