NextSDS Logo
LO

LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12

DANGER arosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Lubrifiant

Overview

LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12 is a arosol substance commonly used lubrifiant.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Skin Irr. Category 2 H315
Aquatic Chronic Category 2 H411
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Arosol extrmement inflammable.
  • H229: Rcipient sous pression: peut clater sous leffet de la chaleur.
  • H315: Provoque une irritation cutane.
  • H336: Peut provoquer somnolence ou vertiges.
  • H411: Toxique pour les organismes aquatiques, entrane des effets nfastes long terme.

Precautionary Statements

  • P251: Ne pas perforer, ni brler, mme aprs usage.
  • P410+P412: Protger du rayonnement solaire. Ne pas exposer une temprature suprieure 50 C/122 F.
  • P211: Ne pas vaporiser sur une flamme nue ou sur toute autre source dignition.
  • P210: Tenir lcart de la chaleur, des surfaces chaudes, des tincelles, des flammes nues et de toute autre source dinflammation. Ne pas fumer.
  • P102: Tenir hors de porte des enfants.
  • P261: viter de respirer les arosols.
  • P273: viter le rejet dans lenvironnement.
  • P302+P352: EN CAS DE CONTACT AVEC LA PEAU: laver abondamment leau et au savon.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Henkel Technologies France S.A.S

national supplier

๐Ÿ“

Rue de Silly 161 92642 Boulogne-Billancourt cedex France

๐ŸŒ

FR

๐Ÿ“ž

+33 (1) 46 84 90 00

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

I.N.R.S.

๐Ÿ“ž

01 45 42 59 59

๐ŸŒ

FR

๐Ÿ•’

24h

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Lubrifiant

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Butane, n- (< 0.1 % butadine)
EC: 203-448-7
106-97-8 30-50% โš ๏ธ Hazardous
Hydrocarbures C6-C7, n-alcanes, isoalcanes, cycliques, <5% n-hexane
EC: 295-763-1
92128-66-0 10-20% โš ๏ธ Hazardous
Propane
EC: 200-827-9
74-98-6 10-20% โš ๏ธ Hazardous
Isobutane
EC: 200-857-2
75-28-5 10-20% โš ๏ธ Hazardous
krosne (ptrole), hydrodsulfur
EC: 265-184-9
64742-81-0 1-10% โš ๏ธ Hazardous

Additional Information

Voir texte complet des phrases H et autres abrviations dans paragraphe 16 "Autres informations". Les substances non classifies peuvent avoir une valeur limite d'exposition sur le lieu de tavail.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Amener au grand air. Si les symptomes persistent, faire appel un mdecin.

Symptoms:

Les vapeurs peuvent provoquer un endormissement et des nauses.

๐Ÿ–๏ธ Skin Contact

Rincer l'eau courante et au savon. Si l'irritation persiste, consulter un mdecin.

Symptoms:

Rougeurs, inflammation.

๐Ÿ‘๏ธ Eye Contact

Rincer l'eau courante (pendant 10 minutes), si ncessaire consulter un mdecin.

Symptoms:

Peut entrainer une irritation des yeux par contact prolong ou rpt.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rincer l'intrieur de la bouche, boire 1 2 verres d'eau,ne pas faire vomir, consulter un mdecin.

๐Ÿšจ Immediate Medical Attention Required

Si les symptomes persistent ou si l'irritation persiste, consulter un mdecin.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
arosol
Critical Property
๐Ÿ“Š Physical State Data
aerosol
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
arosol
๐ŸŽจ Colour
incolore jauntre
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
caractristique
๐Ÿ“Š Odor Threshold
Il n'y a pas de donnes / Non applicable
๐Ÿงช Ph
Il n'y a pas de donnes / Non applicable
๐ŸงŠ Melting Point
Il n'y a pas de donnes / Non applicable
Critical Property
๐Ÿ’จ Boiling Point
Il n'y a pas de donnes / Non applicable
Critical Property
๐Ÿ”ฅ Flash Point
-60 C (-76 F)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Il n'y a pas de donnes / Non applicable
๐Ÿ’จ Vapor Pressure
4000 mbar (25 C (77 F))
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Il n'y a pas de donnes / Non applicable
โš–๏ธ Density
0,6 g/cm3 (20 C (68 F))
Critical Property
๐Ÿ”ฅ Flammability
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Upper Explosive Limit
10,9 %(V)
๐Ÿ“Š Lower Explosive Limit
0,6 %(V)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
230 C (446 F)
๐Ÿ“Š Decomposition Temperature
Il n'y a pas de donnes / Non applicable
๐Ÿ’ง Solubility
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Partition Coefficient
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Solubility In Water
Insoluble (23 C (73.4 F); Solv.: Eau)
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Veiller une bonne ventilation/aspiration.

๐Ÿงค Hand Protection

Gants de protection rsistant aux produits chimiques (EN 374) Matires appropries un contact de courte dure ou des projections (recommandation: indice de protection au moins 2, soit > 30 minutes de temps de permation selon EN 374): Caoutchouc nitrile (NBR; >= 0,4 mm d'paisseur de couche) Matires appropries galement un contact direct et plus long (recommandation: indice de protection 6, soit > 480 minutes de temps de permation selon EN 374): Caoutchouc nitrile (NBR; >= 0,4 mm d'paisseur de couche) Les indications faites sont bases sur la littrature et sur les informations fournies par les fabricants de gants ou sont dduites par analogie de matires similaires. Il faut tenir compte que la dure d'utilisation d'un gant de protection contre les produits chimiques dans la pratique peut tre sensiblement plus courte que le temps de permation dtermin selon EN 374 en raison de multiples facteurs d'influence (comme la temprature p. ex.). Le gant doit tre remplac s'il prsente des signes d'usure.

๐Ÿ‘๏ธ Eye Protection

Des lunettes de scurit avec protections latrales ou des lunettes descurit pour produits chimiques devraient tre portes s'il y un riqued'claboussures. Lquipement de protection pour les yeux doit tre conforme la norme EN166.

๐Ÿ˜ท Respiratory Protection

Assurer une aration et une ventilation suffisantes. Il convient de porter un masque agr ou un respirateur avec unecartouche de vapeur organique si le produit est utilis dans un endroitmal ventil. Type de filtre: A (EN 14387)

๐Ÿฆบ Skin/Body Protection

Porter un vtement de protection appropri. Les vtements de protection doivent tre conformes la norme EN14605 en cas dclaboussures de liquide, et la norme EN13982 en cas dexposition aux poussires.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1950

โš ๏ธ Transport Hazard Class

2.1

๐Ÿš› ADR Transport Precautions

Non applicable

๐Ÿšข IMDG Maritime Transport Precautions

Non applicable

โœˆ๏ธ IATA Air Transport Precautions

Non applicable

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12?

The signal word for this substance is "danger".

What is the physical form of LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12?

LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12 is a arosol appearing as arosol with incolore jauntre color. It has caractristique odor.

What is the solubility of LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12?

Il n'y a pas de donnes / Non applicable

What is LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12 used for?

Lubrifiant

What are the hazard statements for LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12?

This substance has 5 hazard statements: H222: Arosol extrmement inflammable. H229: Rcipient sous pression: peut clater sous leffet de la chaleur. H315: Provoque une irritation cutane. H336: Peut provoquer somnolence ou vertiges. H411: Toxique pour les organismes aquatiques, entrane des effets nfastes long terme.

What is the melting point of LOCTITE LB 8040 known as Loctite 8040 Frz&Rel 400mlx12?

The melting point is Il n'y a pas de donnes / Non applicable and the boiling point is Il n'y a pas de donnes / Non applicable.