Product Name
PLIXXONAT N102
Chemical Name
isocyanates
Synonyms
P-MDI

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Composant di / poly-isocyanate pour la fabrication de polyurethannes
Uses Advised Against
Les application par pulvrisation par les consommateurs finals ne sont pas prises en charge. Toute utilisation par consommateurs finals exigeant avant ou lors de l'utilisation un chauffement au-dessus de la temprature ambiante, n'est pas prise en charge. Le nettoyage professionel utilisant des solvants aprotiques polaires n'est pas pris en charge.

Overview

PLIXXONAT N102 (CAS: 9016-87-9 ) commonly used composant di / poly-isocyanate pour la fabrication de polyurethannes.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 4 H332
Carc. Category 2 H351
Eye Irrit. Category 2 H319
Resp. Sens. Category 1 H334
Skin Irrit. Category 2 H315
Skin Sens. Category 1 H317
STOT RE Category 2 H373
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Provoque une irritation cutane.
  • H317: Peut provoquer une allergie cutane.
  • H319: Provoque une svre irritation des yeux.
  • H332: Nocif par inhalation.
  • H334: Peut provoquer des symptmes allergiques ou d'asthme ou des difficults respiratoires par inhalation.
  • H335: Peut irriter les voies respiratoires.
  • H351: Susceptible de provoquer le cancer.
  • Risque prsum d'effets graves pour les organes la suite d'expositions rptes ou d'une exposition prolonge par inhalation.

Precautionary Statements

  • P280: Porter des gants de protection/des vtements de protection/un quipement de protection des yeux/du visage.
  • P304+P340: EN CAS D'INHALATION: transporter la personne l'extrieur et la maintenir dans une position o elle peut confortablement respirer.
  • P342+P311: En cas de symptmes respiratoires: Appeler un CENTRE ANTIPOISON/un mdecin.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PLIXXENT Holding GmbH

global supplier

📍

Gasstrae 18 22761 Hamburg Germany

🌍

DE

📞

+49 441 68099 190

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

NCEC, National Chemical Emergency Centre

📞

+44 (0) 1235 239 670

🌍

GB

💡

Pour renseignements en cas d'accident de transport et autres urgences:

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

diisocyanate de diphnylmthane, isomres et homologues

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Isocyanic acid, polymethylenepolyphenylene ester
EC: 202-966-0
101-68-8 25-50% ⚠️ Hazardous
2,4'-Diphenylmethaandiisocyanaat
EC: 227-534-9
5873-54-1 5% ⚠️ Hazardous
2,2'methyleendifenyldiisocyanaat
EC: 219-799-4
2536-05-2 2.5% ⚠️ Hazardous

Additional Information

Les substances figurant sur la liste des substances candidates autorisation (liste des SVHC) ventuellement contenues dans le produit au sens du Rglement (CE) n1907/2006 ReaCh sont reportes dans la rubrique 15.

Composition Notes

ingrdients indiquer conformment au rglement (UE) n 1907/2006, ANNEXE II, section 3.1

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Transporter à l'air libre, garder le patient au chaud et au repos. En cas de douleurs persistantes, appeler un médecin.

Symptoms:

douleurs persistantes

🖐️ Skin Contact

Rincer de préférence à l'aide d'un détergent à base du polyéthylèneglycol ou abondamment à l'eau chaude et au savon. En cas d'irritation persistante de la peau, consulter un médecin.

Symptoms:

irritation persistante de la peau; sensibilisation de la peau

👁️ Eye Contact

Enlever les lentilles de contact. Rincer soigneusement à l'eau courante pendant 10 à 15 minutes, les paupières bien écartées et en protégeant l'œil non affecté. Traitement chez un ophtalmologiste.

🍽️ Ingestion/Swallowing

Rincer soigneusement la bouche avec de l'eau. Ne pas faire vomir. Appeler immédiatement le médecin.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

💨 Boiling Point
> 300 C
Critical Property
📊 Vapor Density
Not available
📊 Freezing Point
Donne non disponible.
🔥 Flammability
Donne non disponible.
💧 Solubility
Donne non disponible.
📊 Metal Corrosion
Not available
📊 Partition Coefficient
4,4'-diisocyanate de diphenylmthane (CAS 101-68-8): log Pow 4,51 (22 C, pH 7, OCDE 117, ECHA); 2,4'-diisocyanate de diphenylmthane (CAS 5873-54-1): log Pow 4,51 (22 C, pH 7, OCDE 117, ECHA)
📊 Softening Point
Not available
📊 Colour Intensity
Not available
🔥 Flash Point
226 C
Critical Property
📊 Physical State Data
liquid
📊 Cloud Point
Not available
💨 Vapor Pressure
1 hPa (20 C); 12 hPa (50 C); 17 hPa (55 C)
📊 Crystallisation Point
Not available
📊 Voc Content
Not available
📊 Molecular Weight
Not available
📊 Auto Ignition Temperature
> 500 C
👁️ Appearance
Not available
📊 Dynamic Viscosity
>= 200 mPa*s (20 C)
📊 Solubility In Fat
Not available
📊 Solidification Point
< 0 C
🧪 Ph
Motif pour incication du pH manquante substance/mlange ragit avec l'eau
👃 Odor
sent le moisi
📊 Properties Status
Not available
📊 Bulk Density
Not available
🧊 Melting Point
Donne non disponible.
Critical Property
📊 Form
Not available
📊 Relative Density
Donne non disponible.
⚖️ Density
1,238 g/cm3 (20 C)
Critical Property
📊 Kinematic Viscosity
Donne non disponible.
📊 State Under Standard Conditions
liquide
📊 Lower Explosive Limit
Donne non disponible.
📊 Relative Evaporation Rate
Not available
📊 Explosive Limits
Not available
📊 Odor Threshold
Not available
🎨 Colour
brun
📊 Decomposition Temperature
Donne non disponible.
🧪 Physical State
liquide
Critical Property
📊 Solubility In Water
Not available
💨 Evaporation Rate
Not available
📊 Upper Explosive Limit
Donne non disponible.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une bonne aration des locaux, le cas chant mettre en place une aspiration mcanique sur le lieu de travail.

🧤 Hand Protection

En cas de risque de contact du produit avec la peau, il est suffisant d'utiliser des gants de protection homologus par ex. conformes la norme EN 374. Avant chaque utilisation, le gant de protection doit tre test en fonction de son aptitude spcifique au poste de travail (telles que la rsistance mcanique, la compatibilit avec le produit et les proprits antistatiques). Observer les instructions et les informations du fabricant des gants de protection quant leur utilisation, le stockage, les soins et le remplacement des gants. Remplacer immdiatement les gants de protection endommags ou prsentant des traces d'usures. Aprs contact prolong : Matriau appropri Polychloroprene Epaisseur du matriel >= 0,5 mm Temps de passage >= 480 min; Matriau appropri caoutchouc nitrile Epaisseur du matriel >= 0,35 mm Temps de passage >= 480 min; Matriau appropri butyl-caoutchouc Epaisseur du matriel >= 0,5 mm Temps de passage >= 480 min; Matriau appropri caoutchouc fluor Epaisseur du matriel >= 0,4 mm Temps de passage >= 480 min.

👁️ Eye Protection

Lunettes avec protection latrale (EN 166)

😷 Respiratory Protection

En cas de dpassement des valeurs limites au poste de travail, porter un appareil de respiration homologu cet effet. Prendre les mesures de protection respiratoire appropries en cas de formation d'arosols, de vapeurs et de brouillard lorsque les valeurs limite d'exposition professionnelle ne sont pas spcifies. Le port du masque respiratoire est obligatoire lors d'une aration insuffisante et lors du traitement par pulvrisation. Utiliser un masque air libre; Masque respiratoire, filtre combin A2/P2.

🦺 Skin/Body Protection

Vtements de travail rsistants aux produits chimiques.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is PLIXXONAT N102 known by?

PLIXXONAT N102 is also known as: P-MDI

What is the hazard signal word for PLIXXONAT N102?

The signal word for this substance is "danger".

What is the physical form of PLIXXONAT N102?

PLIXXONAT N102 is a liquide with brun color. It has sent le moisi odor.

What is the solubility of PLIXXONAT N102?

Donne non disponible.

What is PLIXXONAT N102 used for?

Composant di / poly-isocyanate pour la fabrication de polyurethannes

What are the hazard statements for PLIXXONAT N102?

This substance has 8 hazard statements: H315: Provoque une irritation cutane. H317: Peut provoquer une allergie cutane. H319: Provoque une svre irritation des yeux. H332: Nocif par inhalation. H334: Peut provoquer des symptmes allergiques ou d'asthme ou des difficults respiratoires par inhalation. H335: Peut irriter les voies respiratoires. H351: Susceptible de provoquer le cancer. Risque prsum d'effets graves pour les organes la suite d'expositions rptes ou d'une exposition prolonge par inhalation.

What is the melting point of PLIXXONAT N102?

The melting point is Donne non disponible. and the boiling point is > 300 C.