NextSDS Logo
DY

DYK PVC GLUE HD BO 1L*12 NLFR

DANGER Liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DYK PVC GLUE HD BO 1L*12 NLFR

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Colle

Overview

DYK PVC GLUE HD BO 1L*12 NLFR commonly used colle.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Liquide et vapeurs très inflammables.
  • H319: Provoque une sévère irritation des yeux.
  • H336: Peut provoquer somnolence ou vertiges.

Precautionary Statements

  • P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
  • P102: Tenir hors de portée des enfants.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P261: Éviter de respirer les vapeurs.
  • P370 + P378: En cas d'incendie: utiliser pour l'extinction: Brouillard d'eau, Mousse résistant à l'alcool, Poudre d'extinction, Dioxyde de carbone.
  • P403 + P233: Stocker dans un endroit bien ventilé. Maintenir le récipient fermé de manière étanche.
  • P501: Éliminer le contenu/récipient conformément à la réglementation locale/régionale/nationale/internationale.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

📍

Dr. A.F. Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes

🌍

NL

📞

+31 88 3235700

📠

+31 88 3235800

Bison International

manufacturer

📍

Excelsiorlaan 27, B 3 B-1930 Zaventem

🌍

BE

📞

+32 3 710 92 92

📠

+32 3 710 92 90

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Antipoisons

📞

070 245245

🌍

BE

Emergency Contact

📞

8002 - 5500

🌍

LU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Colle

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butanone
EC: 201-159-0
78-93-3 50-100% ⚠️ Hazardous
2,6-di-tert-butyl-p-crésol
EC: 204-881-4
128-37-0 1% ⚠️ Hazardous

Composition Notes

Pour le libellé des phrases de risque citées, se référer au chapitre 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Donner de l'air frais, consulter un médecin en cas de troubles. Aucune mesure particulière n'est requise.

👁️ Eye Contact

Rincer les yeux, pendant plusieurs minutes, sous l'eau courante en écartant bien les paupières. Si les troubles persistent, consulter un médecin.

🍽️ Ingestion/Swallowing

Si les troubles persistent, consulter un médecin.

🚨 Immediate Medical Attention Required

Pas d'autres informations importantes disponibles.

Medical Treatment

Pas d'autres informations importantes disponibles.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Brouillard d'eau, Mousse résistant à l'alcool, Poudre d'extinction, Dioxyde de carbone

Unsuitable Extinguishing Media

Jet d'eau à grand débit

🔥 Fire Fighting Instructions

Refroidir les récipients en danger en pulvérisant de l'eau.

🛡️ Firefighter Protection Equipment

Aucune mesure particulière n'est requise.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🚨 Emergency Procedures

Porter un équipement de sécurité. Eloigner les personnes non protégées.

🌍 Environmental Precautions

Ne pas rejeter dans les canalisations, dans les eaux de surface et dans les nappes d'eau souterraines.

🧹 Cleanup Methods

Recueillir les liquides à l'aide d'un produit absorbant (sable, kieselguhr, neutralisant d'acide, liant universel, sciure).

Cleanup Materials:

produit absorbant (sable, kieselguhr, neutralisant d'acide, liant universel, sciure)

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Liquide
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Selon désignation produit
📊 Colour Intensity
Not available
📊 Form
Liquide
👃 Odor
Caractéristique
📊 Odor Threshold
Non déterminé.
🧪 Ph
Non déterminé.
🧊 Melting Point
Non déterminé.
Critical Property
💨 Boiling Point
79-80,5 °C
Critical Property
🔥 Flash Point
-9 °C
Critical Property
📊 Freezing Point
Non dtermin.
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Non déterminé.
💨 Vapor Pressure
105 hPa
📊 Vapor Density
Non déterminé.
📊 Relative Density
Non déterminé.
📊 Bulk Density
Not available
⚖️ Density
0,96-0,962 g/cm³
Critical Property
🔥 Flammability
Non applicable.
📊 Upper Explosive Limit
11,5 Vol %
📊 Lower Explosive Limit
1,8 Vol %
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
514 °C
📊 Decomposition Temperature
Non déterminé.
💧 Solubility
Not available
📊 Partition Coefficient
Non déterminé.
📊 Solubility In Water
Pas ou peu miscible
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
1450 mPas
📊 Kinematic Viscosity
Non déterminé.
📊 Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

• Veiller à une bonne aération du local, même au niveau du sol (les vapeurs sont plus lourdes que l'air).

• Veiller à une bonne ventilation/aspiration du poste de travail.

• Eviter la formation d'aérosols.

• Tenir à l'abri des sources d'inflammation - ne pas fumer.

• Prendre des mesures contre les charges électrostatiques.

🏪 Storage Conditions

• Stocker dans un endroit frais.

• Tenir les emballages hermétiquement fermés.

• Stocker au frais et au sec dans des fûts bien fermés.

🔥 Fire Prevention Measures

Tenir à l'abri des sources d'inflammation - ne pas fumer.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Sans autre indication, voir point 7.

🧤 Hand Protection

Gants résistant aux solvants. Le matériau des gants doit être impermeable et résistant au produit / à la substance / à la préparation. Choix du matériau des gants en fonction des temps de pénétration, du taux de perméabilité et de la dégradation. Matériau des gants: Butylcaoutchouc. Épaisseur du matériau recommandée: > 0,7 mm. Pour le mélange des produits chimiques mentionnés ci-dessous, le temps de pénétration doit être d'au moins 120 minutes (perméabilité selon la norme EN 374 section 3: taux 4).

👁️ Eye Protection

Lunettes de protection hermétiques. Lunettes de protection recommandées pour le transvasement.

😷 Respiratory Protection

Utiliser un appareil de protection respiratoire si la ventilation est insuffisante. Filtre recommandé pour une utilisation momentanée: Filtre A

🦺 Skin/Body Protection

Vêtement de protection résistant aux solvants

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Pas de décomposition en cas d'usage conforme.

⚗️ Reactivity

Pas d'autres informations importantes disponibles.

⚠️ Hazardous Reactions

Aucune réaction dangereuse connue.

🚫 Conditions to Avoid

Pas d'autres informations importantes disponibles.

🧪 Incompatible Materials

Pas d'autres informations importantes disponibles.

💨 Hazardous Decomposition Products

Danger de formation de produits pyrolysés toxiques

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

Evacuation conformément aux prescriptions légales.

🗂️ Product Disposal Recommendations

Ne doit pas être évacué avec les ordures ménagères. Ne pas laisser pénétrer dans les égouts.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1133

📦 Proper Shipping Name

ADHESIVES

⚠️ Transport Hazard Class

3 Liquides inflammables.

📋 Packing Group

III

🚛 ADR Transport Precautions

Attention: Liquides inflammables.

🚢 IMDG Maritime Transport Precautions

Attention: Liquides inflammables.

✈️ IATA Air Transport Precautions

Attention: Liquides inflammables.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DYK PVC GLUE HD BO 1L*12 NLFR?

The signal word for this substance is "danger".

What is the physical form of DYK PVC GLUE HD BO 1L*12 NLFR?

DYK PVC GLUE HD BO 1L*12 NLFR is a liquide with selon désignation produit color. It has caractéristique odor.

What is DYK PVC GLUE HD BO 1L*12 NLFR used for?

Colle

What are the hazard statements for DYK PVC GLUE HD BO 1L*12 NLFR?

This substance has 3 hazard statements: H225: Liquide et vapeurs très inflammables. H319: Provoque une sévère irritation des yeux. H336: Peut provoquer somnolence ou vertiges.

What is the melting point of DYK PVC GLUE HD BO 1L*12 NLFR?

The melting point is Non déterminé. and the boiling point is 79-80,5 °C.