Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NETTOYANT POUR PLAFONDS ACOUSTIQUE V.S.
Product Code
210.530

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

B

BOMA NV

distributor

Haven 28 - Noorderlaan 17, 2030 Antwerpen

0800-99380

Emergency Contacts

Centre Antipoison

02/345.45.45

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit.
Eye Irrit.
STOT SE

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Peut provoquer une irritation de la peau.
H319 Peut provoquer une irritation de yeux.
H335 Peut provoquer une irritation du système respiratoire.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Natrium Peroxymonosulfaat 10058-23-8 --- No
Kaliumcarbonaat - peroxydraat 0015630-23-8 3% No
Potassium sulfaat 0007778-80-5 --- No
Potassium bisulfaat 007646-39-7 --- No
Magnesium carbonaat 0000546-93-0 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Mettre à l'air frais. Si les symptômes persistent appeler un médecin.

Skin contact

Laver avec beaucoup d'eau. Si une irritation persiste, appeler un médecin.

Eye contact

Laver les yeux immédiatement avec beaucoup d'eau.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dioxyde de carbon. Agent extincteur sec. Mousse.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Neutraliser le produit répandu et rincer avec beaucoup d'eau.

Cleanup methods

récupérer

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Reformer le conteneur.

Storage

Tenir à sec dans un local ventilé.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Porter des gants appropriés en cas de contact prolongée.

Eyes

Porter des lunettes.

Respiratory

Eviter l'inhalation prolongée ou répétée des pulvérisations.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquide
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
opaque
Colour Intensity
---
Form
---
Odor
neutre
Odor Threshold
---
Ph
5 - 7
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
1,2
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Le produit est stable

Reactivity

Produit fort alcalin.

Avoid

Temperature élevée.

Decomposition

Gaz oxygénés

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

12.2 Persistence and degradability

Biodégradable à plus de 90 %..

Le produit est biodégradable à plus de 90 %.

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Etiquettage + emballage, Risques particuliers, Conseils de prudence, Contient. S2: Conserver hors de la portée des enfants.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NETTOYANT POUR PLAFONDS ACOUSTIQUE V.S.?

The signal word is warning.

What is the physical form of NETTOYANT POUR PLAFONDS ACOUSTIQUE V.S.?

NETTOYANT POUR PLAFONDS ACOUSTIQUE V.S. is a liquide with opaque color. It has neutre odor.

What are the hazard statements for NETTOYANT POUR PLAFONDS ACOUSTIQUE V.S.?

This substance has 3 hazard statements:

  • H315: Peut provoquer une irritation de la peau.
  • H319: Peut provoquer une irritation de yeux.
  • H335: Peut provoquer une irritation du système respiratoire.