NextSDS Logo
Safety Data Sheet FR

LUBRIZOL® 3174

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LUBRIZOL® 3174

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Agents améliorant la viscosité

Uses advised against

Aucun n'est identifié.

Manufacturers & Suppliers

LUBRIZOL FRANCE logo

LUBRIZOL FRANCE

manufacturer

25 QUAI DE FRANCE, CS 61062, 76173 ROUEN CEDEX. 76173, FR

(33) 02.35.58.14.00

http://www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Mineral oil --- 10 - 20% Yes

L'huile minérale contenue peut être décrite par une ou plusieurs mentions parmi les suivantes : N° CE 265-157-1, N° d'enregistrement 01-2119484627-25, distillats (pétrole) paraffiniques lourds hydrotraités ; N° CE 265-169-7, N° d'enregistrement 01-2119471299-27, distillats (pétrole) lourds déparaffinés au solvant ; N° CE 265-158-7, N° d'enregistrement 01-2119487077-29, distillats (pétrole) paraffiniques légers hydrotraités ; N° CE 265-159-2, N° d'enregistrement 01-2119480132-48, distillats (pétrole) légers déparaffinés au solvant, fraction légère paraffinique.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Transporter la personne atteinte à l'air frais si l'on observe des troubles.

Skin contact

Laver au savon et à l'eau. Consulter un médecin en cas de symptômes. Laver les vêtements contaminés avant réutilisation.

Eye contact

Toute matière entrant en contact avec les yeux doit être immédiatement rincée à l'eau. Retirer les lentilles de contact si cela est facile à faire.

Ingestion

Traiter les symptômes et obtenir des soins médicaux.

Medical Treatment

Traiter les symptômes.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, produit chimique sec ou mousse. De l'eau peut être utilisée pour refroidir et protéger les matériaux exposés.

Unsuitable media

Ne pas lutter contre l'incendie au jet d'eau pour ne pas propager les flammes.

Specific hazards

Aucun risque exceptionnel d'incendie et d'explosion.

Instructions

Aucune information disponible.

Firefighter Protection

Il est recommandé de porter un appareil respiratoire autonome.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Le port des équipements de protection individuelle est obligatoire, voir les informations de la Section Protection individuelle.

Large spill

Établir une digue autour de grands déversements pour élimination ultérieure.

Environmental

Éviter le rejet dans l'environnement.

Cleanup methods

Ramasser le liquide pour le recycler et/ou le mettre au rebut. Le liquide résiduel peut être absorbé sur du matériel inerte.

Materials: matériel inerte

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Se conformer aux bonnes pratiques d'hygiène industrielle. Assurer une ventilation efficace. Porter un équipement de protection personnelle approprié.

Storage

Conserver à l'écart des matières incompatibles. Pour connaître les matériaux incompatibles, voir section 10.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Aucune exigence particulière dans les conditions normales d'utilisation avec une ventilation suffisante.

Hands

Utilisez des gants en nitrile ou en néoprène. Les gants doivent respecter les exigences stipulées dans la norme EN 374. Pour un contact continu, nous suggérons des gants ayant un temps de protection d'au moins 240 minutes, ou supérieur à 480 minutes s'il est possible d'obtenir des gants appropriés. Pour les applications générales, nous recommandons habituellement des gants dont l'épaisseur est supérieure à 0,35 mm.

Eyes

En cas de risque de contact, le port de lunettes de sécurité à écrans latéraux est conseillé. L'équipement de protection oculaire doit respecter les exigences stipulées dans la norme EN 166.

Respiratory

Consulter un hygiéniste industriel pour déterminer la protection respiratoire convenant à l'utilisation particulière de ce produit. Un équipement de protection respiratoire (EPR) n'est habituellement pas requis lorsqu'il existe une ventilation naturelle ou une ventilation locale par aspiration adéquate pour contrôler l'exposition. En cas de ventilation insuffisante, portez un équipement de protection respiratoire.

Environmental

Aucune information disponible.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquide
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Orange
Colour
Orange
Colour Intensity
---
Form
liquide
Odor
Légère
Odor Threshold
Aucune information disponible.
Ph
Aucune information disponible.
Melting Point
Aucune information disponible.
Boiling Point
Aucune information disponible.
Flash Point
171 °C (Méthode Pensky-Martens en vase clos)
Freezing Point
Aucune information disponible.
Softening Point
---
Solidification Point
18 °C
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Aucune information disponible.
Vapor Pressure
0,0142 psi (76,67 °C)
Vapor Density
---
Relative Density
0,89 - 0,92 (15,6 °C)
Bulk Density
7,54 lb/gal (25 °C)
Density
---
Flammability
Aucune information disponible.
Upper Explosive Limit
Aucune information disponible.
Lower Explosive Limit
Aucune information disponible.
Explosive Limits
---
Auto Ignition Temperature
Aucune information disponible.
Decomposition Temperature
Aucune information disponible.
Solubility
---
Partition Coefficient
Aucune information disponible.
Solubility In Water
Insoluble dans l'eau
Solubility In Fat
---
Molecular Weight
---
Voc Content
Aucune information disponible.
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
24 800 mm2/s (40 °C); 790 mm2/s (100 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Ce produit est stable dans des conditions normales.

Reactivity

Aucune information disponible.

Hazardous reactions

Ne se produit pas.

Avoid

Ne pas exposer à une chaleur excessive, à des sources d'inflammation ou à des matériaux oxydants.

Incompatible

Acides forts. Comburants forts.

Decomposition

La décomposition thermique ou la combustion peut dégager de la fumée, du monoxyde de carbone, du dioxyde de carbone et d'autres produits issus d'une combustion incomplète.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Écotoxicité

Poisson Mineral oil LC 50 (Pimephales promelas, 4 DY): > 100 mg/l

12.1 Écotoxicité

Invertébrés Aquatiques Mineral oil CE50 (Cladocère, 2 DY): > 10 000 mg/l CE50 (Cladocère, 21 DY): > 10 mg/l NOEC (Cladocère, 21 DY): > 10 mg/l

12.1 Écotoxicité

Toxicité pour les plantes aquatiques Mineral oil CE50 (Algue verte (Scenedesmus quadricauda), 3 Jours): > 100 mg/l

12.2 Persistence et Dégradabilité

Biodégradation Mineral oil Formation de dioxyde de carbone 31 % (28 DY, OECD TG 301 B)

Rapport DBO/DCO

Aucune donnée disponible

12.3 Potentiel de Bioaccumulation

Facteur de Bioconcentration (BCF) Aucune donnée disponible Coefficient de Partage n-octanol/eau (log Kow) Aucune donnée disponible

12.4 Mobilité

Aucune donnée disponible

12.5 Résultats des évaluations PBT et VPVB

Aucune donnée disponible

12.6 Autres Effets Néfastes

Aucune information disponible.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Le traitement, le stockage, le transport et l'élimination des déchets doivent s'effectuer conformément aux réglementations gouvernementales, provinciales et locales applicables.

Disposal

Étant donné que les récipients contiennent des résidus du produit, respecter les avertissements sur l'étiquette même après avoir vidé le récipient.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Tous les composants sont en conformité avec les exigences de notification dans les inventaires listés.

Chemical Safety Assessment Not performed

Les informations utilisées afin de confirmer le statut de conformité de ce produit peuvent s'écarter des informations relatives aux produits chimiques indiquées à la section 3.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LUBRIZOL® 3174?

The signal word is no signal word.

What is the physical form of LUBRIZOL® 3174?

LUBRIZOL® 3174 is a liquide appearing as orange with orange color. It has légère odor.

What is LUBRIZOL® 3174 used for?

Agents améliorant la viscosité

What is the melting point of LUBRIZOL® 3174?

The melting point is Aucune information disponible. and the boiling point is Aucune information disponible..