NextSDS Logo
BU

BUTACLEAN 4904

NO SIGNAL WORD Vloeistof. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
BUTACLEAN 4904

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Antischuimmiddel
Uses Advised Against
Niet bekend.

Overview

BUTACLEAN 4904 commonly used antischuimmiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Geen.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Veolia Water Technologies & Solutions Belgium BV

manufacturer

Toekomstlaan 54 Industriepark Wolfstee 2200 HERENTALS

BE

+32 14 / 25 91 11

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+44(0)1235 239670

GB

24/7

Languages: EN

Europa, Midden-Oosten, Afrika, Isral (Europa en Engels sprekende landen)

SUEZWATERTECH29003-NCEC

+44(0)1235 239671

GB

Languages: AR

Middle East & Africa (speaking Arabic)

ANTIGIFCENTRUM

+32 70 245 245

BE

Officieel adviesorgaan

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mengsels

General Composition

Polydimethylsiloxaan

Composition Notes

De bestanddelen zijn niet gevaarlijk of zijn onder de vereiste openbaringslimieten.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

In de frisse lucht plaatsen.

Skin Contact

Met zeep en water wassen.

Symptoms:

Irritatie

Eye Contact

Met water afspoelen.

Symptoms:

Irritatie

Ingestion/Swallowing

De mond spoelen.

Immediate Medical Attention Required

Niet beschikbaar

Medical Treatment

Niet beschikbaar

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Vloeistof.
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Kleurloos
Colour Intensity
Not available
Form
vloeibaar
Odor
Geen
Odor Threshold
Not available
Ph
Niet beschikbaar
Melting Point
< -34 C
Critical Property
Boiling Point
- 204 C
Critical Property
Flash Point
Niet beschikbaar
Critical Property
Freezing Point
< -34 C
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
< 1 (ether=1)
Vapor Pressure
< 1 mm Hg
Vapor Density
Not available
Relative Density
0,97
Bulk Density
Not available
Density
Not available
Flammability
Niet van toepassing.
Upper Explosive Limit
Niet beschikbaar
Lower Explosive Limit
Niet beschikbaar
Explosive Limits
Not available
Auto Ignition Temperature
Niet beschikbaar
Decomposition Temperature
Niet beschikbaar
Solubility
Not available
Partition Coefficient
Niet beschikbaar
Solubility In Water
< 0,01 %
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
0 % (berekend)
Metal Corrosion
Not available
Dynamic Viscosity
100 cps
Kinematic Viscosity
Niet beschikbaar
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Er moet een goede algehele ventilatie worden gebruikt. Ventiliatiesnelheden moeten zijn aangepast aan de omstandigheden. Gebruik, indien van toepassing, afgesloten procesruimten, plaatselijke afzuiging of andere technische middelen om de concentraties in de lucht onder de aanbevolen blootstellingslimieten te houden. Wanneer er geen blootstellingslimieten zijn vastgesteld, houd dan de concentraties in de lucht op een aanvaardbaar niveau.

Hand Protection

Toepasselijke chemisch-resistente handschoenen dragen. Veiligheidshandschoenen (plastic, ondoordringbaar) (Bescherming tegen kortstondig contact) Nitrile handschoenen (Bescherming tegen kortstondig contact) Rubberen handschoenen (Bescherming tegen kortstondig contact) CEN : EN 420

Eye Protection

Draag een veiligheidsbril met zij-afscherming (of een veiligheidsbril die geheel op het gezicht aansluit). CEN : EN 166

Respiratory Protection

Bij ontoereikende ventilatie een geschikte adembescherming dragen.

Skin/Body Protection

CEN : EN ISO 13688

Environmental Exposure Controls

Emissies van ventilatie- of procesapparatuur moet worden gecontroleerd om na te gaan dat zij voldoen aan de vereisten van milieubeschermingswetten. Rookgaswassers, filters of technische aanpassingen aan de procesapparatuur kunnen nodig zijn om de emissies tot aanvaardbaar niveaus te brengen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for BUTACLEAN 4904?

The signal word for this substance is "no signal word".

What is the physical form of BUTACLEAN 4904?

BUTACLEAN 4904 is a vloeistof. with kleurloos color. It has geen odor.

What is BUTACLEAN 4904 used for?

Antischuimmiddel

What is the melting point of BUTACLEAN 4904?

The melting point is < -34 C and the boiling point is - 204 C.