NextSDS Logo
BI

BIOPLUS BA2905

NO SIGNAL WORD Vast. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
BIOPLUS BA2905

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Bacterile stammen voor koolwaterstoffen afbraakprocessen in biologische afvalwatersystemen
Uses Advised Against
Niet bekend.

Overview

BIOPLUS BA2905 commonly used bacterile stammen voor koolwaterstoffen afbraakprocessen in biologische afvalwatersystemen.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Geen.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Veolia Water Technologies & Solutions Belgium BV

manufacturer

Toekomstlaan 54 Industriepark Wolfstee 2200 HERENTALS

BE

+32 14 / 25 91 11

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+44(0)1235 239670

GB

24/7

Languages: EN

Europa, Midden-Oosten, Afrika, Isral (Europa en Engels sprekende landen)

SUEZWATERTECH29003-NCEC

+44(0)1235 239671

GB

24/7

Languages: AR

Middle East & Africa (speaking Arabic)

ANTIGIFCENTRUM

+ 32 70 245 245

BE

Officieel adviesorgaan

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mengsels

General Composition

Poeder, mengsel van niet pathogene levensvatbare bacterile culturen

Composition Notes

De bestanddelen zijn niet gevaarlijk of zijn onder de vereiste openbaringslimieten.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Move to fresh air.

Symptoms:

Irritation of the respiratory tract; symptoms may develop or persist.

Skin Contact

Wash with soap and water.

Symptoms:

Irritation of the skin; symptoms may occur and persist.

Eye Contact

Rinse with water.

Symptoms:

Irritation of the eyes; symptoms may occur and persist.

Ingestion/Swallowing

Rinse mouth.

Symptoms:

Symptoms may occur.

Immediate Medical Attention Required

Consult a doctor if symptoms develop or persist (inhalation, skin, eyes). Seek medical help if symptoms occur (ingestion). Treat symptomatically.

Medical Treatment

Treat symptomatically.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Vast.
Critical Property
Physical State Data
solid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Bruin
Colour Intensity
Not available
Form
Poeder
Odor
Licht.
Odor Threshold
Not available
Ph
7,5 (1% DISP.)
Melting Point
Niet beschikbaar
Critical Property
Boiling Point
Niet beschikbaar
Critical Property
Flash Point
- 100 C P-M(CC)
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
< 1 (ether=1)
Vapor Pressure
< 1 mm Hg
Vapor Density
< 0,1 (Lucht = 1)
Relative Density
21 C
Bulk Density
Not available
Density
Not available
Flammability
Niet beschikbaar.
Upper Explosive Limit
Niet beschikbaar
Lower Explosive Limit
Niet beschikbaar
Explosive Limits
Not available
Auto Ignition Temperature
Niet beschikbaar
Decomposition Temperature
Niet beschikbaar
Solubility
Not available
Partition Coefficient
Niet beschikbaar
Solubility In Water
0 %
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
0 % (Geschat)
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Niet beschikbaar
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Als het materiaal gemalen of gesneden wordt of bij een bewerking gebruikt wordt waarbij stof vrijkomt, dient geschikte plaatselijke afzuiging te worden toegepast, zodat de blootstelling beneden de aanbevolen blootstellingslimieten blijft.

Hand Protection

Toepasselijke chemisch-resistente handschoenen dragen. Veiligheidshandschoenen (plastic, ondoordringbaar) (Bescherming tegen kortstondig contact) PVC handschoenen (Bescherming tegen kortstondig contact) Rubberen handschoenen (Bescherming tegen kortstondig contact) Laagdikte: 0.5 mm Penetratietijd: > 480 min CEN : EN 374-1/2/3/4; EN 420

Eye Protection

Draag een veiligheidsbril met zij-afscherming (of een veiligheidsbril die geheel op het gezicht aansluit). CEN : EN 166

Respiratory Protection

Draag een ademhalingsmasker met stoffilter. Gebruik bij onvoldoende ventilatie een ademhalingsmasker met filter type: P2. CEN : EN 140; EN 143; EN 149

Skin/Body Protection

Draag geschikte beschermende kleding. CEN : EN ISO 13688

Environmental Exposure Controls

Emissies van ventilatie- of procesapparatuur moet worden gecontroleerd om na te gaan dat zij voldoen aan de vereisten van milieubeschermingswetten. Rookgaswassers, filters of technische aanpassingen aan de procesapparatuur kunnen nodig zijn om de emissies tot aanvaardbaar niveaus te brengen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for BIOPLUS BA2905?

The signal word for this substance is "no signal word".

What is the physical form of BIOPLUS BA2905?

BIOPLUS BA2905 is a vast. with bruin color. It has licht. odor.

What is BIOPLUS BA2905 used for?

Bacterile stammen voor koolwaterstoffen afbraakprocessen in biologische afvalwatersystemen

What is the melting point of BIOPLUS BA2905?

The melting point is Niet beschikbaar and the boiling point is Niet beschikbaar.