NextSDS Logo
BI

BIOPLUS BA2900

NO SIGNAL WORD Vast. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
BIOPLUS BA2900

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Additief voor waterbehandeling.
Uses Advised Against
Niet bekend.

Overview

BIOPLUS BA2900 commonly used additief voor waterbehandeling..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Geen.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Veolia Water Technologies & Solutions Belgium BV

manufacturer

Toekomstlaan 54 Industriepark Wolfstee 2200 HERENTALS

BE

+32 14 / 25 91 11

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+44(0)1235 239670

GB

24/7

Languages: EN

Europa, Midden-Oosten, Afrika, Isral

Emergency Contact

+44(0)1235 239671

GB

Languages: AR

Middle East & Africa

ANTIGIFCENTRUM

+ 32 70 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mengsel

General Composition

Micro-organismen mengsel op een natuurlijke drager

Composition Notes

De bestanddelen zijn niet gevaarlijk of zijn onder de vereiste openbaringslimieten.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

In de frisse lucht plaatsen. Raadpleeg een arts als de symptomen zich ontwikkelen of aanhouden.

Symptoms:

irriterend zijn voor de luchtwegen

Skin Contact

Met zeep en water wassen. Wanneer irritatie ontstaat en aanhoudt, dient u medische hulp in te roepen.

Symptoms:

irriterend zijn voor de huid. Gebruikte organismen zijn niet-pathogeen maar zijn in staat om infectie te veroorzaken in contact met open wonden.

Eye Contact

Wrijf niet in de ogen. Met water afspoelen. Wanneer irritatie ontstaat en aanhoudt, dient u medische hulp in te roepen.

Symptoms:

irriterend zijn voor de ogen. Gebruikte organismen zijn niet-pathogeen maar zijn in staat om infectie te veroorzaken in contact met ogen

Ingestion/Swallowing

De mond spoelen. Zoek medische hulp als de symptomen optreden.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Appearance
Not available
Solubility In Fat
Not available
Solubility In Water
0 %
Vapor Density
Not available
Density
Not available
Bulk Density
Not available
Voc Content
0 % (Geschat)
Kinematic Viscosity
Niet beschikbaar
Crystallisation Point
Not available
Melting Point
Niet beschikbaar
Critical Property
Colour
Bruin
State Under Standard Conditions
Not available
Odor Threshold
Not available
Solidification Point
Not available
Decomposition Temperature
Niet beschikbaar
Flash Point
P-M(CC) None
Critical Property
Relative Density
Not available
Boiling Point
Niet beschikbaar
Critical Property
Explosive Limits
Not available
Dynamic Viscosity
Not available
Cloud Point
Not available
Properties Status
Not available
Vapor Pressure
< 1 mm Hg
Colour Intensity
Not available
Physical State Data
solid
Lower Explosive Limit
Niet beschikbaar
Evaporation Rate
< 1 (ether=1)
Molecular Weight
Not available
Odor
Licht.
Physical State
Vast.
Critical Property
Auto Ignition Temperature
Niet beschikbaar
Ph
7,5 (1% DISP.)
Solubility
Not available
Partition Coefficient
Niet beschikbaar
Upper Explosive Limit
Niet beschikbaar
Softening Point
Not available
Metal Corrosion
Not available
Freezing Point
Niet beschikbaar
Relative Evaporation Rate
Not available
Form
Poeder
Flammability
Niet beschikbaar.
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Als het materiaal gemalen of gesneden wordt of bij een bewerking gebruikt wordt waarbij stof vrijkomt, dient geschikte plaatselijke afzuiging te worden toegepast, zodat de blootstelling beneden de aanbevolen blootstellingslimieten blijft.

Hand Protection

Toepasselijke chemisch-resistente handschoenen dragen. Geschikte handschoenen kunnen aanbevolen worden door de handschoenenleverancier. Veiligheidshandschoenen (plastic, ondoordringbaar) (Bescherming tegen kortstondig contact) Laagdikte: 0.5 mm Penetratietijd: > 480 min CEN : EN 420

Eye Protection

Draag een veiligheidsbril met zij-afscherming (of een veiligheidsbril die geheel op het gezicht aansluit). CEN : EN 166

Respiratory Protection

Draag een ademhalingsmasker met stoffilter. Gebruik bij onvoldoende ventilatie een ademhalingsmasker met filter type: P2. CEN : EN 140; EN 143; EN 149

Skin/Body Protection

Draag geschikte beschermende kleding. CEN : EN ISO 13688

Environmental Exposure Controls

Emissies van ventilatie- of procesapparatuur moet worden gecontroleerd om na te gaan dat zij voldoen aan de vereisten van milieubeschermingswetten. Rookgaswassers, filters of technische aanpassingen aan de procesapparatuur kunnen nodig zijn om de emissies tot aanvaardbaar niveaus te brengen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for BIOPLUS BA2900?

The signal word for this substance is "no signal word".

What is the physical form of BIOPLUS BA2900?

BIOPLUS BA2900 is a vast. with bruin color. It has licht. odor.

What is BIOPLUS BA2900 used for?

Additief voor waterbehandeling.

What is the melting point of BIOPLUS BA2900?

The melting point is Niet beschikbaar and the boiling point is Niet beschikbaar.