Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
SIGMACOVER CM MIOCOAT BASE .
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Sigma Coatings DECO BELUX
manufacturer
Genkerstecnweg 311 B-3500 Hasselt
BE
+32(0)11 27 87 01
+32(0)11 27 87 00
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
070/245.245
BE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| xylcen EC: 215-535-7 | 1330-20-7 | 10-25% | β οΈ Hazardous |
| 2-methylpropan-1-ol EC: 201-148-0 | 78-83-1 | 2.5% | β οΈ Hazardous |
| ethylbenzen- EC: 202-849-4 | 100-41-4 | 2.5-10% | β οΈ Hazardous |
| epoxyhars (gemiddeld moleculgewicht <700) EC: 500-033-5 | 25068-38-6 | 2.5-10% | β οΈ Hazardous |
| 1-Methoxy-2-Propanol EC: 203-539-1 | 107-98-2 | 2.5% | β οΈ Hazardous |
| Nonylfenol EC: 246-672-0 | 25154-52-3 | 2.5% | β οΈ Hazardous |
| ALUMINIUM METAL EC: 231-072-3 | 7429-90-5 | 2.5-10% | β οΈ Hazardous |
| Nafta (aardolie), waterstofontzwavelde zware Nota (s) P EC: 265-185-4 | 64742-82-1 | 2.5% | β οΈ Hazardous |
Composition Notes
Zie voor componenten met een wettelijke grenswaarde (MAC) hoofdstuk 8.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
π« Inhalation Exposure
Verse lucht toedienen. Betreflende persoon in rusttocstand brengen en warn houden. Bij onregelmatige ademhaling of adcmstilstand kunstmatige bedeming toepassen. Bij bewusteloosheid stabielezijligging toepassen en medische advies inwinnen.
ποΈ Skin Contact
Verontreinigde kleding omiddellijk uittrekken. De huid grondig wassen met water en zcep of een erkende huidreiniger.
ποΈ Eye Contact
Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vlociend water spoelen. Contactlensen uitdoen. Medisch advies inwinnen.
π½οΈ Ingestion/Swallowing
Bij inslikken direkt arts raadplegen. Het slachtoffer laten rusten. Geen braken opwecken.
π¨ Immediate Medical Attention Required
Als de ziekteverschijnscln nict van voorbijgaande aard zijn en in geval van twijfel dient medische hulp te worden ingeroepen. Medisch advies inwinnen (na oogcontact). Bij bewusteloosheid medisch advies inwinnen. Bij inslikken direkt arts raadplegen.
Medical Treatment
Bij onregelmatige ademhaling of adcmstilstand kunstmatige bedeming toepassen.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
π Engineering Controls
Minimale hoeveelheid te ventileren lucht die nodig is voor 1 liter product: Om de MAC te bereiken : 1,292 m/l Basis: MAC (NL); Om 10% OEG te bereiken : 75 m3/l. Indien werknemers zich in een spuitcabine bevinden, dient ventilatie aanwezig te zijn voor eventuele spuitdeeltjes en oplosmiddeldampen.
π§€ Hand Protection
Veiligheidshandschoenen.
ποΈ Eye Protection
Het dragen van een chemicaliΓ«nbestendige beschermingsbril is verplicht. Afsluitende bril.
π· Respiratory Protection
Indien werknemers zich in een spuitcabine bevinden, dienen zij een verse-lucht kap te dragen tijdens het spuitproces tot het moment dat de concentratie is gedaald tot beneden de MAC-waarde. P2A2-halfgelaatscombimasker.
π¦Ί Skin/Body Protection
Het personeel dient beschermende kleding te dragen. Na contact met de huid grondig wassen. Werkkleding dient niet uit textiel te bestaan, dat in geval van brand een gevaarlijk smeltgedrag vertoont. Het dragen van antistatische schoenen is verplicht.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
π·οΈ UN Number
1263
π¦ Proper Shipping Name
PAINT
β οΈ Transport Hazard Class
3
π Packing Group
III
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for SIGMACOVER CM MIOCOAT BASE?
The signal word for this substance is "warning".