NextSDS Logo
Safety Data Sheet NL

SIGMACOVER 300 BASE

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SIGMACOVER 300 BASE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

verf

Manufacturers & Suppliers

P

PPG Coatings SPRL/BVBA

manufacturer

Noordersingel 23, B-2040 Borgerhout

+32 3 3606311

Emergency Contacts

Emergency Contact

+31 20 4075210

NATIONAL POISONS INFORMATION CENTRE

+31 30 2748888

CENTRE ANTI-POISONS/ANTIGIFCENTRUM

+32 70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Ontvlambaar
Carc.Cat.2 Cat. 2
Mut.Cat.2 Cat. 2
Xn
Kan overgevoeligheid veroorzaken bij contact met de huid.
Xi
N

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
xyleen EC: 215-535-7 1330-20-7 12.5 - 20% Yes
ethylbenzeen EC: 202-849-4 100-41-4 2.5 - 10% Yes
reactieprodukt: bisfenolA-epichloorhydrine epoxyhars (gemiddeld molecuulgewicht 700) 25068-38-6 5 - 10% Yes
1-methoxy-2-propanol EC: 203-539-1 107-98-2 1 - 2.5% Yes
benzo[def]chryseen EC: 200-028-5 50-32-8 0.1 - 0.25% Yes
nonylfenol EC: 246-672-0 25154-52-3 0.25 - 1% Yes
benzo[a]antraceen EC: 200-280-6 56-55-3 0.25 - 1% Yes
benzo(e)acefenantryleen EC: 205-911-9 205-99-2 0.25 - 1% Yes
benzo(k)fluorantheen EC: 205-916-6 207-08-9 0.25 - 1% Yes
dibenzo[a,h]antraceen EC: 200-181-8 53-70-3 0.02 - 0.1% Yes
naftaleen EC: 202-049-5 91-20-3 0.25 - 1% Yes
kwarts (SiO2) (< 5 m) EC: 238-878-4 14808-60-7 10 - 25% Yes
2-methylnaftaleen EC: 202-078-3 91-57-6 0.25 - 1% Yes
creosootolie, acenafteenfractie EC: 292-605-3 90640-84-9 1 - 2.5% Yes
pek, koolteer, hoge temperatuur* EC: 266-028-2 65996-93-2 10 - 25% Yes
destillaten (koolteer), zware olin EC: 292-607-4 90640-86-1 0.1 - 1% Yes
reactieprodukt: bisfenolA-epichloorhydrine epoxyhars (gemiddeld molecuulgewicht 700 < MW < 1000) 25068-38-6 2.5 - 5% Yes
fenantreen EC: 201-581-5 85-01-8 0.25 - 1% Yes
pyreen EC: 204-927-3 129-00-0 0.1 - 1% Yes
chryseen EC: 205-923-4 218-01-9 0.1 - 0.25% Yes
benzo[e]pyreen EC: 205-892-7 192-97-2 0.1 - 0.25% Yes
bifenyl EC: 202-163-5 92-52-4 0.1 - 0.25% Yes

Notes

De producent verklaart dat voor de in hoofdstuk 3 niet vermelde R-zinnen, de totale hoeveelheid gevaarlijke componenten beneden de grens liggen. Indien meerdere ingredienten met gelijke namen of nummers verschijnen hebben deze verschillende gevaren eigenschappen, bijvoorbeeld vlampunt.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid stabiele zijligging toepassen en medische advies inwinnen.

Skin contact

Verontreinigde kleding onmiddellijk uittrekken. De huid grondig wassen met water en zeep of een erkende huidreiniger. Als gemorst product op de kleding vlam vat, spoelen met ruim water. Verwijder loszittende kleding.

Eye contact

Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlenzen uitdoen. Medisch advies inwinnen.

Ingestion

Bij inslikken direkt arts raadplegen. Het slachtoffer laten rusten. GEEN braken opwekken.

Immediate Medical Attention

Als de ziekteverschijnselen niet van voorbijgaande aard zijn en in geval van twijfel dient medische hulp te worden ingeroepen. Medisch advies inwinnen (voor ogen). Bij bewusteloosheid (na inademing) medische advies inwinnen. Bij inslikken direkt arts raadplegen. Medische hulp inroepen (voor verbranding). Bij een ongeval of indien men zich onwel voelt onmiddellijk een arts raadplegen (indien mogelijk het etiket tonen). Dit veiligheidsinformatieblad aan de dienstdoende arts tonen.

Medical Treatment

Symptomatisch behandelen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ventilation must be present in spray booths for spray particles and solvent vapors. Workers in spray booths must wear a fresh-air hood during the spraying process until the concentration drops below the MAC value.

Hands

For prolonged or repeated contact, use chemical-resistant gloves as indicated in standard EN 374: Protective gloves against chemicals and microorganisms. Recommended gloves: Viton(R) with a minimum breakthrough time of 480 minutes. For long-term and regular contact, a glove with protection class 6 (breakthrough time more than 480 minutes according to EN 374) is recommended. If only short contact is expected, a glove with protection class 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended. ATTENTION: The choice of a specific glove for certain applications and the duration of use should also be based on all relevant workplace factors such as, but not limited to: other chemicals used, physical requirements (cut/puncture protection, ease of use, thermal protection), possible bodily reactions to the glove material, as well as the instructions/specifications provided by the glove supplier.

Eyes

Wearing chemical-resistant safety glasses is mandatory.

Respiratory

If workers - even if they are not directly involved in processing the product - are in a spray booth, ventilation must be present for any spray particles and solvent vapors. Under these circumstances, they must wear a fresh-air hood during the spraying process until the concentration has fallen below the MAC value.

Skin/Body

Personnel must wear protective clothing. Wash thoroughly after skin contact. Work clothing should not consist of textiles that show dangerous melting behavior in case of fire. Wearing antistatic shoes is mandatory.

Environmental

Refer to national legislation in chapter 15 for regulations regarding environmental protection.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Auto Ignition Temperature
- 270 C
Solubility In Fat
---
Odor
sterk aromatisch
State Under Standard Conditions
---
Vapor Density
---
Appearance
---
Lower Explosive Limit
1.09 %(V) 47.77 g/m3
Explosive Limits
---
Properties Status
---
Freezing Point
---
Solidification Point
---
Physical State
---
Upper Explosive Limit
7.92 %(V) 347.49 g/m3
Relative Evaporation Rate
---
Crystallisation Point
---
Boiling Point
---
Odor Threshold
---
Vapor Pressure
---
Softening Point
---
Physical State Data
liquid
Ph
---
Colour Intensity
---
Molecular Weight
---
Density
1.54 g/cm3 bij 20 C
Dynamic Viscosity
2,750 mPa.s bij 23 C
Form
viskeus
Bulk Density
---
Metal Corrosion
---
Solubility In Water
niet mengbaar
Melting Point
---
Partition Coefficient
---
Evaporation Rate
---
Solubility
---
Kinematic Viscosity
---
Decomposition Temperature
---
Voc Content
---
Cloud Point
---
Colour
---
Relative Density
---
Flash Point
31.2 C
Flammability
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
VERF
Transport Class
3
Packing Group
III
ADR

Transport op eigen terrein: vervoer de materialen altijd in gesloten containers, die rechtop staan, geetiketteerd en gezekerd zijn. Stel zeker dat de personen die het product vervoeren, weten wat zij dienen te doen in geval van een ongeluk of morsing.

IMDG

Transport op eigen terrein: vervoer de materialen altijd in gesloten containers, die rechtop staan, geetiketteerd en gezekerd zijn. Stel zeker dat de personen die het product vervoeren, weten wat zij dienen te doen in geval van een ongeluk of morsing.

IATA

Transport op eigen terrein: vervoer de materialen altijd in gesloten containers, die rechtop staan, geetiketteerd en gezekerd zijn. Stel zeker dat de personen die het product vervoeren, weten wat zij dienen te doen in geval van een ongeluk of morsing.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SIGMACOVER 300 BASE?

The signal word is na: r-phrases.

What is SIGMACOVER 300 BASE used for?

verf