NextSDS Logo
Hy

Hydrex 6099

NO SIGNAL WORD Vloeistof. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Hydrex 6099

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Wastewater Flocculant Afvalwaterbehandeling

Overview

Hydrex 6099 is a waterige oplossing. substance commonly used wastewater flocculant afvalwaterbehandeling.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Geen.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

VWS Belgium

national supplier

5 Esperantolaan TIENEN 3300 Belgium - Luxemburg

BE

+32 16 78 16 20

+32 16 78 16 29

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+1-760-476-3961 (Code:333239)

US

Antigifcentrum / Centre anti-poison

070/245.245

BE

7j/7 et 24h/24

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Andere Bestanddelenandere beneden rapporteerbare niveaus 90 - 100

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
sodium nitrate
EC: 231-554-3
7631-99-4 5-10% Hazardous
acide adipique
EC: 204-673-3
124-04-9 1-3% Hazardous

Composition Notes

De volledige tekst van alle R- en S-zinnen wordt weergegeven in Rubriek 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

In de frisse lucht brengen. Bel een arts als de symptomen zich ontwikkelen of aanhouden.

Skin Contact

Medische hulp inroepen als irritatie optreedt en aanhoudt.

Eye Contact

Spoel de ogen onmiddellijk met grote hoeveelheden water. Medische hulp inroepen als irritatie optreedt en aanhoudt.

Ingestion/Swallowing

Mond spoelen. Medische hulp inroepen als aandoeningen merkbaar worden.

Medical Treatment

Symptomatisch behandelen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Evaporation Rate
Not available
State Under Standard Conditions
Not available
Freezing Point
< - 10 (< 14 F)
Metal Corrosion
Not available
Solubility In Water
Niet beschikbaar.
Boiling Point
> 100 (> 212 F)
Critical Property
Softening Point
Not available
Voc Content
Not available
Kinematic Viscosity
Not available
Auto Ignition Temperature
Not available
Flash Point
Niet beschikbaar.
Critical Property
Decomposition Temperature
Not available
Cloud Point
Not available
Colour
Melkachtig. Wit
Colour Intensity
Not available
Odor
Salty Kenmerkend.
Density
1,2
Critical Property
Physical State Data
liquid
Bulk Density
Not available
Odor Threshold
Not available
Vapor Density
Not available
Physical State
Vloeistof.
Critical Property
Crystallisation Point
Not available
Relative Density
Not available
Ph
3 - 5
Partition Coefficient
Niet beschikbaar.
Upper Explosive Limit
Not available
Form
Vloeibaar.
Molecular Weight
Not available
Lower Explosive Limit
Not available
Solubility In Fat
Not available
Flammability
Not available
Explosive Limits
Not available
Properties Status
Not available
Solubility
Not available
Solidification Point
Not available
Appearance
Waterige oplossing.
Relative Evaporation Rate
Not available
Vapor Pressure
Niet beschikbaar.
Melting Point
< - 10 (< 14 F)
Critical Property
Dynamic Viscosity
< 5000 cP
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Er moet een goede algehele ventilatie worden gebruikt (gewoonlijk 10 luchtverversingen per uur). Ventiliatiesnelheden moeten zijn aangepast aan de omstandigheden. Gebruik, indien van toepassing, afgesloten procesruimten, plaatselijke afzuiging of andere technische middelen om de concentraties in de lucht onder de aanbevolen blootstellingslimieten te houden. Wanneer er geen blootstellingslimieten zijn vastgesteld, houd dan de concentraties in de lucht op een aanvaardbaar niveau.

Hand Protection

Draag beschermende handschoenen die voldoen aan NF EN 374. Chemicalinbestendige handschoenen worden aanbevolen.

Eye Protection

Draag een veiligheidsbril met zijkleppen (of een beschermbril) en een gelaatsscherm. Aanraking met de ogen vermijden. Voor enige handeling, draag beschermende bril met zijschermen die voldoen aan de NF EN 166.

Respiratory Protection

Bij ontoereikende ventilatie een geschikte adembescherming dragen.

Skin/Body Protection

Contact met de huid vermijden. Draag geschikte beschermende kleding.

Environmental Exposure Controls

Bij elk omvangrijk ongewild vrijkomen dient de manager voor veiligheid en milieu te worden ingelicht.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Hydrex 6099?

The signal word for this substance is "no signal word".

What is the physical form of Hydrex 6099?

Hydrex 6099 is a vloeistof. appearing as waterige oplossing. with melkachtig. wit color. It has salty kenmerkend. odor.

What is Hydrex 6099 used for?

Wastewater Flocculant Afvalwaterbehandeling

What is the melting point of Hydrex 6099?

The melting point is < - 10 (< 14 F) and the boiling point is > 100 (> 212 F).