NextSDS Logo
In

Interflon Fin Clean All

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Interflon Fin Clean All

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrile reiniger op waterbasis.

Overview

Interflon Fin Clean All commonly used industrile reiniger op waterbasis..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Eye Irrit.
Skin Irr.

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Interflon b.v. company logo - Safety Data Sheet supplier organization

Interflon b.v.

manufacturer

๐Ÿ“

P.O. Box 1070 NL-4700 BB Roosendaal The Netherlands

๐ŸŒ

NL

๐Ÿ“ž

+31(0)165.55.39.11

๐Ÿ“ 

+31(0)165.53.80.82

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+32 702.452.45

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

Waterige oplossing van alkalin, tensides en hydrotopen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2-butoxyethanol
EC: 203-905-0
111-76-2 2.5-10% โš ๏ธ Hazardous
natriumdodecylbenzeensulfonaat, zuiver
EC: 246-680-4
25155-30-0 2.5-10% โš ๏ธ Hazardous
2,2',2"-nitrilotriethanol
EC: 203-049-8
102-71-6 2.5-10% โš ๏ธ Hazardous
Alcoholethoxylate 68439-46-3 2.5-10% โš ๏ธ Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

Composition Notes

Interflon Fin Clean All is goedgekeurd door de NSF voor gebruik in de voedselverwerkende industrie als algemene reiniger (Cat. Code A1) met registratienummer 128223.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Voor verse lucht zorgen. Bij bewusteloosheid ligging en vervoer in stabiele zijligging.

๐Ÿ–๏ธ Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen.

๐Ÿ‘๏ธ Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

๐Ÿฝ๏ธ Ingestion/Swallowing

Geen braken teweegbrengen en onmiddellijk medische hulp raadplegen. Onmiddellijk arts raadplegen. Mond spoelen en overvloedig water drinken.

๐Ÿšจ Immediate Medical Attention Required

Onmiddellijk medische hulp raadplegen. Onmiddellijk arts raadplegen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Blauw
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Vloeibaar
๐Ÿ‘ƒ Odor
Mild
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
12,9
๐ŸงŠ Melting Point
Niet bepaald.
Critical Property
๐Ÿ’จ Boiling Point
- 100C
Critical Property
๐Ÿ”ฅ Flash Point
Niet bruikbaar.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
23 hPa
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,05 g/ml
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 150C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Volledig mengbaar.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
1 mPas
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ventilation or extraction systems.

๐Ÿงค Hand Protection

Safety gloves. Gloves made of neoprene, Gloves made of PVC. The choice of a suitable glove depends not only on the material, but also on other quality characteristics and varies from manufacturer to manufacturer. Since the product is composed of several substances, the durability of the glove materials cannot be calculated in advance and must therefore be tested before use. The exact penetration time can be found from the glove manufacturer; take this into account.

๐Ÿ‘๏ธ Eye Protection

Tightly fitting safety glasses.

๐Ÿ˜ท Respiratory Protection

Respiratory protection recommended. Filter A/P2.

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3267

๐Ÿ“ฆ Proper Shipping Name

CORROSIVE LIQUID, BASIC, ORGANIC, N.O.S.

โš ๏ธ Transport Hazard Class

8

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Interflon Fin Clean All?

The signal word for this substance is "no signal word".

What is Interflon Fin Clean All used for?

Industrile reiniger op waterbasis.

What is the melting point of Interflon Fin Clean All?

The melting point is Niet bepaald. and the boiling point is - 100C.