NextSDS Logo
1-

1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur

DANGER vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur
Product Code
101990
Chemical Name
butaan-1-ol, n-butanol
Synonyms
Butyl alcohol

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

REACH Registration Number
01-2119484630-38-0003

Registration, Evaluation, Authorisation and Restriction of Chemicals - EU regulation compliance

Uses Information

Identified Uses
Reagens voor analyse

Overview

1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur (CAS: 71-36-3 ) commonly used reagens voor analyse.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Liq. Category 3 H226
Acute Tox. Category 4 H302
STOT SE Category 3 H335
Skin Irrit. Category 2 H315
Eye Dam. Category 1 H318
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Ontvlambare vloeistof en damp.
  • H302: Schadelijk bij inslikken.
  • H315: Veroorzaakt huidirritatie.
  • H318: Veroorzaakt ernstig oogletsel.
  • H335: Kan irritatie van de luchtwegen veroorzaken.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.

Precautionary Statements

  • P210: Verwijderd houden van warmte.
  • P280: Ogbescherming dragen.
  • P302 + P352: BIJ CONTACT MET DE HUID: met veel water en zeep wassen.
  • P304 + P340: NA INADEMING: het slachtoffer in de frisse lucht brengen en laten rusten in een houding die het ademen vergemakkelijkt.
  • P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P313: Een arts raadplegen.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA

manufacturer

64271 Darmstadt * Duitsland

DE

+49 6151 727780

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Merck KGaA

+49 6151 722440

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butaan-1-ol, n-butanol
EC: 200-751-6
71-36-3 100% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

frisse lucht. Bij onwel bevinden, arts waarschuwen.

Skin Contact

met ruim voldoende water afspoelen. Verontreinigde kleding verwijderen.

Eye Contact

uitspoelen met ruim voldoende water. Onmiddellijk een oogarts raadplegen.

Ingestion/Swallowing

oppassen als slachtoffer braakt. Houdt de luchtwegen vrij. Een arts raadplegen.

Symptoms:

Gevaar voor aspiratie! Uitvallen van de longfunctie mogelijk na aspireren van het braaksel.

Immediate Medical Attention Required

Geen gegevens beschikbaar.

Medical Treatment

Geen gegevens beschikbaar.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Flash Point
34 C Methode: DIN 51755 Part 1
Critical Property
Bulk Density
Not available
Relative Density
Geen gegevens beschikbaar.
Melting Point
-89 C
Critical Property
Form
vloeibaar
Physical State
vloeibaar
Critical Property
Kinematic Viscosity
Not available
Crystallisation Point
Not available
Properties Status
Not available
Odor Threshold
0,004 - 48,7 ppm
Softening Point
Not available
Solubility In Water
77 g/l bij 20 C
Appearance
Not available
State Under Standard Conditions
Not available
Odor
ethanol-achtig
Lower Explosive Limit
1,4 %(V)
Solidification Point
Not available
Explosive Limits
Not available
Voc Content
Not available
Partition Coefficient
log Pow: 0,88 (experimenteel) (Lit.) Een bio-accumulatie is niet te verwachten.
Upper Explosive Limit
11,3 %(V)
Vapor Pressure
6,7 hPa bij 20 C (berekend)
Ph
7 bij 70 g/l 20 C
Freezing Point
Not available
Molecular Weight
Not available
Evaporation Rate
Geen gegevens beschikbaar.
Vapor Density
Not available
Solubility
Not available
Colour Intensity
Not available
Solubility In Fat
Not available
Physical State Data
liquid
Metal Corrosion
Not available
Boiling Point
116 - 118 C bij 1.013 hPa Methode: DIN 53171
Critical Property
Decomposition Temperature
Geen gegevens beschikbaar.
Relative Evaporation Rate
Not available
Cloud Point
Not available
Dynamic Viscosity
2,95 mPa.s bij 20 C
Flammability
Geen gegevens beschikbaar.
Density
0,81 g/cm3 bij 20 C
Critical Property
Auto Ignition Temperature
Geen gegevens beschikbaar.
Colour
kleurloos
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Technische maatregelen en geschikte werkprocedures zouden prioriteit moeten hebben boven het gebruik van persoonlijke beschermingsmiddelen. Zie paragraaf 7.1.

Hand Protection

Volledig contact: Handschoenenmateriaal: Nitrilrubber, Handschoendikte: 0,40 mm, Penetratietijd: > 480 min. Spat contact: Handschoenenmateriaal: Polychloropreen, Handschoendikte: 0,65 mm, Penetratietijd: > 120 min. De te gebruiken beschermende handschoenen, moeten voldoen aan de specificaties van EG regeling 89/686/EEG en de daaruit voortkomende norm EN374, bij voorbeeld KCL 730 Camatril -Velours (volledig contact), KCL 720 Camapren (spat contact).

Eye Protection

Nauw aansluitende veiligheidsstofbril

Respiratory Protection

Nodig indien dampen/aerosolen gevormd worden. Aanbevolen filtertype: Filter A (volgens DIN 3181) voor dampen van organische verbindingen. De ondernemer moet er voor zorgen dat onderhoud, reiniging en beproeving van adembeschermingstoestellen worden uitgevoerd volgens de voorschriften van de leverancier. Deze maatregelen moeten uitvoerig zijn gedocumenterd.

Skin/Body Protection

Vlamvertragende, antistatische beschermingskleding

Environmental Exposure Controls

Afval niet in de gootsteen werpen. Risico op explosie.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN 1120

Proper Shipping Name

Butanolen

Transport Hazard Class

3

Packing Group

III

ADR Transport Precautions

ja

IMDG Maritime Transport Precautions

ja

IATA Air Transport Precautions

nee

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is 1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur known by?

1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur is also known as: Butyl alcohol

What is the hazard signal word for 1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur?

The signal word for this substance is "danger".

What is the physical form of 1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur?

1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur is a vloeibaar with kleurloos color. It has ethanol-achtig odor.

What is 1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur used for?

Reagens voor analyse

What are the hazard statements for 1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur?

This substance has 6 hazard statements: H226: Ontvlambare vloeistof en damp. H302: Schadelijk bij inslikken. H315: Veroorzaakt huidirritatie. H318: Veroorzaakt ernstig oogletsel. H335: Kan irritatie van de luchtwegen veroorzaken. H336: Kan slaperigheid of duizeligheid veroorzaken.

What is the melting point of 1-butanol voor analyse EMSURE ACS, ISO, Reag. Ph Eur?

The melting point is -89 C and the boiling point is 116 - 118 C bij 1.013 hPa Methode: DIN 53171.