Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
2-propanol voor analyse EMSURE ACS,ISO,Reag. Ph Eur commonly used reagens voor analyse, chemische productie.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H225: Licht ontvlambare vloeistof en damp.
- H319: Veroorzaakt ernstige oogirritatie.
- H336: Kan slaperigheid of duizeligheid veroorzaken.
Precautionary Statements
- P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
- P233: In goed gesloten verpakking bewaren.
- P240: Opslag- en opvangreservoir aarden.
- P241: Explosieveilige elektrische/ ventilatie-/ verlichtingsapparatuur gebruiken.
- P242: Vonkvrij gereedschap gebruiken.
- BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Millipore
global supplier
Merck Life Science BV/SRL
national supplier
Brusselsesteenweg 288 B-3090 OVERIJSE
BE
+32 (0)3 899-1301
+32 (0)3 899-1311
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
CHEMTREC
+(32) 28 083237
BE
Anti-poison centre
070 245245
BE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
substanceChemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
2-Propanol EC: 200-661-7 | 67-63-0 | 20-100% | โ ๏ธ Hazardous |
Additional Information
Voor de volledige text van H-zinnen zoals vermeld in deze rubriek, zie rubriek 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Na inademen: frisse lucht. Arts waarschuwen.
๐๏ธ Skin Contact
Verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen/ afdouchen.
๐๏ธ Eye Contact
Na oog contact: uitspoelen met ruim voldoende water. Oogarts raadplegen. Contactlenzen uitnemen.
๐ฝ๏ธ Ingestion/Swallowing
Na inslikken: slachtoffer onmiddellijk water laten drinken (niet meer dan twee glazen). Een arts raadplegen.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐งค Hand Protection
Full contact: Material: Nitrilrubber, Minimal layer thickness: 0,4 mm, Breakthrough time: 480 min, Tested material: Camatril (KCL 730 / Aldrich Z677442, Size M). Splash contact: Material: Chloropreen, Minimal layer thickness: 0,65 mm, Breakthrough time: 120 min, Tested material: KCL 720 Camapren. Recommendations are for the product as mentioned in the safety data sheet for the specified applications. For solutions or mixtures with other substances under different conditions than stated in EN 16523-1, contact the supplier of CE-approved gloves.
๐๏ธ Eye Protection
Safety glasses. Use face and/or eye protection tested and approved by official institutions such as NIOSH (US) or EN166 (EU).
๐ท Respiratory Protection
Recommended filter type: Filter A (according to DIN 3181) for vapors of organic compounds. The employer must ensure that maintenance, cleaning, and testing of respiratory protective devices are carried out according to the supplier's regulations. These measures must be extensively documented.
๐ฆบ Skin/Body Protection
Flame-retardant, antistatic protective clothing.
๐ Environmental Exposure Controls
Do not allow product to enter sewage system. Risk of explosion.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
1219
๐ฆ Proper Shipping Name
ISOPROPANOL
โ ๏ธ Transport Hazard Class
3
๐ Packing Group
II
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for 2-propanol voor analyse EMSURE ACS,ISO,Reag. Ph Eur?
The signal word for this substance is "danger".
What is the physical form of 2-propanol voor analyse EMSURE ACS,ISO,Reag. Ph Eur?
2-propanol voor analyse EMSURE ACS,ISO,Reag. Ph Eur is a vloeibaar with kleurloos color. It has alcoholisch odor.
What is 2-propanol voor analyse EMSURE ACS,ISO,Reag. Ph Eur used for?
Reagens voor analyse, Chemische productie
What are the hazard statements for 2-propanol voor analyse EMSURE ACS,ISO,Reag. Ph Eur?
This substance has 3 hazard statements: H225: Licht ontvlambare vloeistof en damp. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken.
What is the melting point of 2-propanol voor analyse EMSURE ACS,ISO,Reag. Ph Eur?
The melting point is -89,5 C and the boiling point is 82,4 C bij 1.013 hPa.