NextSDS Logo
Az

Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy

DANGER SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy
Product Code
Prolabo)
Chemical Name
Acetic acid (glacial)
Synonyms
glacial

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

REACH Registration Number
01-2119475328-30-0000

Registration, Evaluation, Authorisation and Restriction of Chemicals - EU regulation compliance

Uses Information

Identified Uses
voor gebruik in het laboratorium en de productie van chemische stoffen.

Overview

Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy (CAS: 64-19-7 ) commonly used voor gebruik in het laboratorium en de productie van chemische stoffen..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Liq. Category 3 H226
Skin Corr. Category 1A H314

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Ontvlambare vloeistof en damp.
  • H314: Veroorzaakt ernstige brandwonden en oogletsel.

Precautionary Statements

  • P210: Verwijderd houden van warmte/vonken/open vuur/hete oppervlakken. Niet roken.
  • P243: Voorzorgsmaatregelen treffen tegen ontladingen van statische elektriciteit.
  • P280: Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
  • P301+P330+P331: NA INSLIKKEN: de mond spoelen GEEN braken opwekken.
  • P304+P340: NA INADEMING: het slachtoffer in de frisse lucht brengen en laten rusten in een houding die het ademen vergemakkelijkt.
  • NA blootstelling of bij onwel voelen: Onmiddellijk een ANTIGIFCENTRUM of een arts raadplegen.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

VWR International Europe bvba

regional supplier

Geldenaaksebaan 464 3001 Leuven, Researchpark Haasrode 2020

BE

+32 16 385 011

+32 16 385 385

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+44 (0) 1270 502894

GB

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Acetic acid (glacial)
EC: 200-580-7
64-19-7 Not specified Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Onmiddellijk een vergiftigingencentrum of een arts raadplegen. Slachtoffer naar de frisse lucht brengen en warm en rustig houden. bij ademhalingsklachten of ademstilstand kunstmatige beademing toepassen.

Skin Contact

Na aanraking met de huid onmiddellijk wassen met veel water en zeep. vervuilde, gedrenkte kleding direct uittrekken.

Symptoms:

brandwonden

Eye Contact

bij contact met de ogen direct met geopende oogleden 10 tot 15 minuten met stromend water spoelen en oogarts consulteren. Onbeschadigd oog beschermen. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen.

Ingestion/Swallowing

Onmiddellijk een vergiftigingencentrum of een arts raadplegen. Laat slachtoffer niet braken. Mond grondig met water spoelen. Niets te eten of te drinken geven.

Immediate Medical Attention Required

Onmiddellijk een vergiftigingencentrum of een arts raadplegen. Behandeling doot een arts is direct noodzakelijk, omdat niet behandelde brandwonden in moeilijk geneesbare wonden kunnen veranderen.

Medical Treatment

Geen gegevens beschikbaar

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Not available
Physical State Data
Not available
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Not available
Colour Intensity
Not available
Form
Not available
Odor
Not available
Odor Threshold
Not available
Ph
Not available
Melting Point
17C
Critical Property
Boiling Point
118C (1013 hPa)
Critical Property
Flash Point
38,5C
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
Not available
Vapor Density
Not available
Relative Density
1,05 g/cm (20C)
Bulk Density
Not available
Density
Not available
Flammability
Ontvlambare vloeistof en damp.
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
Not available
Auto Ignition Temperature
485C
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Not available
Solubility In Water
Not available
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
1,22 mPa*s (20C)
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Technische maatregelen en de toepassing van geschikte arbeidsmethoden hebben voorrang boven het gebruik van persoonlijke beschermingsuitrustingen. Bij open hanteren moeten installaties met plaatselijke afzuiging gebruikt worden.

Hand Protection

Bij de omgang met chemische werkstoffen mogen handschoenen die tegen chemicalin beschermen met CEkenmerk inclusief het viercijferige controlenummer, gedragen worden. Aanbevolen handschoenenfabrikaten DIN-/ENnormen: DIN EN 374 Bij gepland hergebruik handschoenen voor het uittrekken reinigen en goed geventileerd bewaren. Bij kortdurig huidcontact Geschikt materiaal: Geen gegevens beschikbaar Dikte van het handschoenenmateriaal Geen gegevens beschikbaar Doordringtijd (maximale draagduur) Geen gegevens beschikbaar Bij herhaald handcontact Geschikt materiaal: Geen gegevens beschikbaar Dikte van het handschoenenmateriaal Geen gegevens beschikbaar Doordringtijd (maximale draagduur) Geen gegevens beschikbaar

Eye Protection

Montuurbril met zijbescherming dragen DIN-/EN-normen: DIN EN 166

Respiratory Protection

Adembescherming is noodzakelijk bij: arosol- of nevelvorming. Geschikte ademhalingsapparatuur: Geen gegevens beschikbaar Geschikt materiaal: Geen gegevens beschikbaar

Skin/Body Protection

Voor de bescherming tegen direct huidcontact is lichaamsbescherming (boven de normale werkkleding) noodzakelijk.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

2789

Transport Hazard Class

8

Packing Group

II

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy known by?

Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy is also known as: glacial

What is the hazard signal word for Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy?

The signal word for this substance is "danger".

What is Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy used for?

voor gebruik in het laboratorium en de productie van chemische stoffen.

What are the hazard statements for Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy?

This substance has 2 hazard statements: H226: Ontvlambare vloeistof en damp. H314: Veroorzaakt ernstige brandwonden en oogletsel.

What is the melting point of Azijnzuur 100% AnalaR NORMAPUR analytical reagent, for cryoscopy?

The melting point is 17C and the boiling point is 118C (1013 hPa).