NextSDS Logo
Safety Data Sheet NL

Power Thermic Fluid

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Power Thermic Fluid

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Smeermiddel

Manufacturers & Suppliers

Power Oil n.v. logo

Power Oil n.v.

distributor

Vlamingstraat 33-35 B-8560 Wevelgem

www.poweroil.be

Emergency Contacts

Emergency Contact

056/41.69.11

Emergency Contact

0498/90.30.01

Antigifcentrum, Centre Antipoisons, Vergiftungszentrum

070/245 245

NL, FR, DE

Antigifcentrum, p/a Militair hospitaal Koningin Astrid, Bruynstraat 1, 1120 Brussel Centre Antipoisons, c/o Hôpital Militaire Reine Astrid, Rue Bruyn 1, 1120 Bruxelles

(+32) 02 264 96 36

NL, FR

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Hoog geraffineerde minerale oliën en additieven Deze hoog geraffineerde olie bevat <3% (w/w) DMSO extract, bepaald volgens IP346. Dit mengsel bevat geen stoffen die vermeld moeten worden conform Annex II, sectie 3.2

Chemical Name CAS Number Concentration Hazardous
Hoog geraffineerde minerale oliën en additieven --- --- No

Niet van toepassing

Notes

Opmerkingen

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.

Skin contact

De huid met overvloedig water wassen.

Eye contact

Als voorzorgsmaatregel de ogen met water uitspoelen.

Ingestion

Bij onwel voelen een antigifcentrum of een arts raadplegen. Niet laten braken.

Symptoms: Kan leiden tot opname in de longen, met een chemische longontsteking als gevolg.

Immediate Medical Attention

Symptomatische behandeling.

Medical Treatment

Symptomatische behandeling.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Zorg voor een goede ventilatie van de werkplek.

Hands

Beschermende handschoenen. Type Materiaal: Herbruikbare Nitrilrubber (NBR), Neopreen rubber (HNBR), Polyvinylchloride (PVC). Permeatie: 4 (> 120 minuten), 5 (> 240 minuten), 6 (>480 minuten). Dikte (mm): >=0,35. Penetratie: 3 (> 0.65). Norm: EN 374.

Eyes

Nauwaansluitende bril. Type: Veiligheidsbril. Gebruik: Druppeltjes. Kenmerken: Helder. Norm: EN 166.

Respiratory

Bij ontoereikende ventilatie een geschikt ademhalingsapparaat gebruiken

Skin/Body

Draag geschikte beschermende kleding.

Environmental

Voorkom lozing in het milieu.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State Data
liquid
Decomposition Temperature
Geen gegevens beschikbaar
Auto Ignition Temperature
Geen gegevens beschikbaar
Partition Coefficient
Geen gegevens beschikbaar
Odor
karakteristiek
Explosive Limits
---
Bulk Density
---
Molecular Weight
---
Boiling Point
Geen gegevens beschikbaar
Crystallisation Point
---
Form
---
Vapor Density
---
Lower Explosive Limit
---
Appearance
---
Ph
Geen gegevens beschikbaar
Metal Corrosion
---
Softening Point
---
Flammability
Niet van toepassing
Voc Content
0%
Solubility In Fat
---
Solidification Point
---
Kinematic Viscosity
31 mm²/s (40 °C)
Properties Status
---
Vapor Pressure
Geen gegevens beschikbaar
Colour Intensity
---
Cloud Point
---
Colour
Lichtgeel
Melting Point
Niet van toepassing
Dynamic Viscosity
Geen gegevens beschikbaar
Solubility
Zo goed als niet mengbaar.
Odor Threshold
Geen gegevens beschikbaar
Density
0,847 kg/l (15 °C)
Relative Density
Geen gegevens beschikbaar
Upper Explosive Limit
---
Relative Evaporation Rate
Geen gegevens beschikbaar
Freezing Point
-15 °C
Physical State
Vloeibaar
State Under Standard Conditions
---
Flash Point
195 °C
Evaporation Rate
---
Solubility In Water
Zo goed als niet mengbaar.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Niet van toepassing
Shipping Name
Niet van toepassing
Transport Class
Niet van toepassing
Packing Group
Niet van toepassing
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Power Thermic Fluid?

The signal word is no signal word.

What is the physical form of Power Thermic Fluid?

Power Thermic Fluid is a vloeibaar with lichtgeel color. It has karakteristiek odor.

What is the solubility of Power Thermic Fluid?

Zo goed als niet mengbaar.

What is Power Thermic Fluid used for?

Smeermiddel

What is the melting point of Power Thermic Fluid?

The melting point is Niet van toepassing and the boiling point is Geen gegevens beschikbaar.

Compliance Scanner