Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Waterstofperoxide 30% H₂O₂ (Perhydrol®) pro analyse ISO
- Product Code
- 107209
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagens voor analyse Chemische productie
Manufacturers & Suppliers
Merck KGaA
manufacturer
64271 Darmstadt, Germany
+49 6151 72-2440
Emergency Contacts
Merck KGaA
+49 6151 722440
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
GHS05
GHS06
Hazard Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Waterstofperoxide EC: 231-765-0 | 7722-84-1 | --- | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
frisse lucht.
met ruim voldoende water afspoelen. Verontreinigde kleding verwijderen.
uitspoelen met ruim voldoende water met de oogleden wijd open gehouden.
onmiddellijk veel water drinken.
Immediate Medical Attention
Onmiddellijk een oogarts waarschuwen. Arts waarschuwen.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Op de omgeving afstemmen.
Niet brandbaar. Werkt brandbevorderend door zuurstofafgifte.
Firefighter Protection
Blijf niet in de gevaarlijke zone zonder beademingsapparatuur die onafhankelijk is van de omgevingslucht. Om huidcontact te vermeiden, houd een veilige afstand en draag geschikte beschermende kleding.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Adem geen dampen/aerosolen in. Vermijd contact met de stof. In afgesloten ruimten voor toevoer van frisse lucht zorgen.
Niet in riolering laten geraken.
Met vloeistofabsorberend en neutraliserend matriaal, b.v. Chemizorb® H⁺ (Art.Nr. 101595) opnemen. Reinig het getroffen oppervlak.
Materials: vloeistofabsorberend en neutraliserend matriaal, b.v. Chemizorb® H⁺ (Art.Nr. 101595)
Related Products
Similar products with comparable safety profiles
Waterstofperoxide 30% (Perhydrol®) voor analyse EMSURE® ISO
---
Waterstofperoxide 30% (Perhydrol®) voor analyse EMSURE® ISO
---
Waterstofperoxide 30% (Perhydrol®) voor analyse EMSURE® ISO
UFI: 9VPX-658R-V99Q-9WPY
Waterstofperoxide 30% (Perhydrol TM) voor analyse EMSURE® ISO
UFI: 9VPX-658R-V99Q-9WPY
Waterstofperoxide 30% AnalaR NORMAPUR® for traces analysis
CAS: 7722-84-1
Fluorwaterstofzuur 40% pro analyse ISO
---
Waterstofperoxide >30%
UFI: 2G3U-QMP7-WU1W-UKN8
Waterstofperoxide in oplossing 30 %
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Geen nadere eisen.
Goed afgesloten. Verwijderd van brandbare materialen en ontstekingsbronnen en hitte. Bij +5°C tot +30°C. Beschermd tegen licht.
Verwijderd van brandbare materialen en ontstekingsbronnen en hitte.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Bij vol contact: Handschoen materiaal: Natuurlijk latex, Dikte van de laag: 0.6 mm, Doorbraaktijd: > 480 Min. Bij sproei contact: Handschoen materiaal: Nitrilrubber, Dikte van de laag: 0.11 mm, Doorbraaktijd: > 30 Min. De te gebruiken beschermende handschoenen, moeten voldoen aan de specificaties van EG regeling 89/686/EEG en de daaruit voortkomende norm EN374, bij voorbeeld KCL 706 Lapren® (volledig contact), 741 Dermatril® L (spat contact).
benodigd
nodig indien dampen/aerosolen gevormd worden.
Het soort lichaamsbescherming moet al naargelang van de concentratie en de hoeveelheid gevaarlijke stoffen op de werkplek gekozen worden. Geschikte beschermende kleding.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
lichtgevoelig; hittegevoelig. Stabilisatoren: pyridine-2,6-dicarbonzuur (Dipicolinezuur)
Gevaar voor ontploffing met: / Kans op ontbranding of vorming van brandbare gassen of dampen met: alkalimetalen, alkalizouten, alkalihydroxiden, aardalkalimetalen, metalen, metalen in poedervorm, metaaloxiden, metaalzouten, niet-metalen, niet-metaal oxiden, aldehyden, alcoholen, aminen, ammoniak, hydrazine en derivaten, hydriden, brandbare stoffen, ethers, zuren, anhydriden, oxiderend middel, organische stoffen, peroxiverbindingen, onzuiverheden/poeder, Permanganaten, organische oplosmiddelen, organische stikstofverbindingen, messing.
Verhitting, licht, hitte
alkalimetalen, alkalizouten, alkalihydroxiden, aardalkalimetalen, metalen, metalen in poedervorm, metaaloxiden, metaalzouten, niet-metalen, niet-metaal oxiden, aldehyden, alcoholen, aminen, ammoniak, hydrazine en derivaten, hydriden, brandbare stoffen, ethers, zuren, anhydriden, oxiderend middel, organische stoffen, peroxiverbindingen, onzuiverheden/poeder, Permanganaten, organische oplosmiddelen, organische stikstofverbindingen, messing.
geen informatie beschikbaar
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxische effecten
Toxisch effect op vis en plankton bij hoge concentraties; geen verwachte aantasting van afvalwaterzuiveringsinstallaties bij juist gebruik.
Biologische afbraak
Biologisch gemakkelijk afbreekbaar; afbraakproducten zijn water en zuurstof.
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemicaliën moeten met inachtneming van de desbetreffende nationale voorschriften afgevoerd worden. Onder www.retrologistik.de vindt u zowel de landen- en stofspecifieke informatie als de contact partners.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2014
- Shipping Name
- HYDROGEN PEROXIDE, AQUEOUS SOLUTION
- Transport Class
- 5.1
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Etikettering volgens EG richtlijnen: Symbool Xn (Schadelijk), R-zinnen 22-41, S-zinnen 26-39.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Waterstofperoxide 30% H₂O₂ (Perhydrol®) pro analyse ISO?
The signal word is danger.
What is the physical form of Waterstofperoxide 30% H₂O₂ (Perhydrol®) pro analyse ISO?
Waterstofperoxide 30% H₂O₂ (Perhydrol®) pro analyse ISO is a vloeibaar appearing as vloeibaar with kleurloos color. It has licht doordringend odor.
What is Waterstofperoxide 30% H₂O₂ (Perhydrol®) pro analyse ISO used for?
Reagens voor analyse Chemische productie
What are the hazard statements for Waterstofperoxide 30% H₂O₂ (Perhydrol®) pro analyse ISO?
This substance has 2 hazard statements:
- H301: Schadelijk bij opname door de mond.
- H318: Gevaar voor ernstig oogletsel.
What is the melting point of Waterstofperoxide 30% H₂O₂ (Perhydrol®) pro analyse ISO?
The melting point is -26 °C and the boiling point is 107 °C.