NextSDS Logo
Safety Data Sheet DE

UP-SYSTEM MEKP-Härter FL 505 SN

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
UP-SYSTEM MEKP-Härter FL 505 SN
Product Code
158.154

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Härter

Uses advised against

Industrielle Verwendung, berufsmäßige Verwendung, öffentliche Verwendung

Manufacturers & Suppliers

V

Vosschemie GmbH

manufacturer

Esinger Steinweg 50, 25436 Uetersen, Deutschland

04122 717 0

Emergency Contacts

Giftinformationszentrum (GIZ)-Nord

0551 19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Org. Perox. Cat. D H242
Acute Tox. Cat. 4 H302
Acute Tox. Cat. 4 H332
Skin Corr. Cat. 1B H314
Eye Dam. Cat. 1 H318

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H242 Erwärmung kann Brand verursachen.
H302 + H332 Gesundheitsschädlich bei Verschlucken oder Einatmen.
H314 Verursacht schwere Verätzungen der Haut und schwere Augenschäden.

Precautionary Statements

P101 Ist ärztlicher Rat erforderlich, Verpackung oder Kennzeichnungsetikett bereithalten.
P102 Darf nicht in die Hände von Kindern gelangen.
P210 Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen.
P234 Nur in Originalverpackung aufbewahren.
P260 Nebel oder Dampf nicht einatmen.
P280 Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz tragen.
P301 + P330 + P331 BEI VERSCHLUCKEN: Mund ausspülen. KEIN Erbrechen herbeiführen.
P303 + P361 + P353 BEI BERÜHRUNG MIT DER HAUT (oder dem Haar): Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen.
P305 + P351 + P338 + P310 BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen. Sofort GIFTINFORMATIONSZENTRUM/ Arzt anrufen.
P310 Sofort GIFTINFORMATIONSZENTRUM/ Arzt anrufen.
P403 + P235 An einem gut belüfteten Ort aufbewahren. Kühl halten.
P501 Inhalt/ Behälter einer zugelassenen Entsorgungsanlage gemäß den lokalen, regionalen, nationalen und internationalen Bestimmungen zuführen.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Reaktionsmasse von Butan-2,2-diyl Dihydroperoxid und dioxydi-butan-2,2-diyl Dihydroperoxid EC: 700-954-4 1338-23-4 25 - 40% Yes
Butanon EC: 201-159-0 78-93-3 1 - 10% Yes
Wasserstoffperoxid in Lösung EC: 231-765-0 7722-84-1 1 - 5% Yes
Tributylamin EC: 203-058-7 102-82-9 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

An die frische Luft bringen. Sauerstoff oder, falls erforderlich, künstliche Beatmung. Sofort Arzt hinzuziehen.

Symptoms: Gesundheitsschädlich bei Einatmen.

Skin contact

Sofort mit Seife und viel Wasser abwaschen. Beschmutzte Kleidung und Schuhe ausziehen. Sofort ärztliche Behandlung notwendig.

Symptoms: Verätzungen

Eye contact

Sofort mindestens 15 Minuten mit viel Wasser abspülen, auch unter den Augenlidern. Auge weit geöffnet halten beim Spülen. Kontaktlinsen entfernen. Unverletztes Auge schützen. Sofort Arzt hinzuziehen.

Symptoms: Verursacht schwere Augenschäden.

Ingestion

KEIN Erbrechen herbeiführen. Sofort Arzt hinzuziehen. Patient umgehend in ein Krankenhaus bringen. Mund mit Wasser ausspülen.

Symptoms: Gesundheitsschädlich bei Verschlucken.

Immediate Medical Attention

Sofort Arzt hinzuziehen. Patient umgehend in ein Krankenhaus bringen. Sofort ärztliche Behandlung notwendig.

Medical Treatment

Symptomatische Behandlung.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Kohlendioxid (CO2), Löschpulver, Wassersprühstrahl, Alkoholbeständiger Schaum

Unsuitable media

Wasservollstrahl

Specific hazards

Im Brandfall können gefährliche Zersetzungsprodukte entstehen.

Instructions

Entfernen Sie unbeschädigte Behälter aus dem Brandbereich, wenn dies sicher ist. Zur Kühlung geschlossener Behälter Wassersprühstrahl einsetzen.

Firefighter Protection

Umgebungsluftunabhängiges Atemschutzgerät und Chemieschutzanzug tragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Persönliche Schutzausrüstung tragen. Personen in Sicherheit bringen. Alle Zündquellen entfernen. Nicht rauchen. Für angemessene Lüftung sorgen. Kontakt mit Haut, Augen und Kleidung vermeiden. Atemschutz tragen. Ein Einatmen der Dämpfe oder Nebel vermeiden.

Environmental

Nicht in die Umwelt gelangen lassen.

Cleanup methods

Mit inertem Aufsaugmittel aufnehmen. Zusammenkehren und in nicht brennbarem Behälter lagern. Zur Entsorgung in geeignete und verschlossene Behälter geben. Nach der Reinigung Spuren mit Wasser wegspülen.

Materials: Inertes Aufsaugmittel

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Persönliche Schutzausrüstung tragen. Von Hitze- und Zündquellen fernhalten. Behälter mit Vorsicht öffnen und handhaben. Behälter trocken und dicht geschlossen halten. Nie ungebrauchtes Material in die Lagerbehälter zurückgeben. Zersetzungsrisiko. Verunreinigung durch leicht oxidierbare Stoffe und Polymerisationsbeschleuniger vermeiden. Bei unzureichender Belüftung Atemschutzgerät anlegen. Dämpfe/Staub nicht einatmen. Aerosolbildung vermeiden. Berührung mit den Augen vermeiden.

Storage

Behälter trocken und dicht geschlossen halten. Vor direkter Sonneneinstrahlung schützen.

Fire prevention

Von offenen Flammen, heißen Oberflächen und Zündquellen fernhalten. Vor direkter Sonneneinstrahlung schützen. Schlag und Reibung vermeiden. Maßnahmen gegen elektrostatisches Aufladen treffen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technische Maßnahmen treffen, um mit den maximalen Arbeitsplatzkonzentrationen in Übereinstimmung zu sein.

Hands

Material: Nitrilkautschuk, Richtlinie: DIN EN 374; Material: Neopren, Richtlinie: DIN EN 374; Material: PVC, Richtlinie: DIN EN 374; Anmerkungen: Handschuhe müssen entfernt und ersetzt werden, wenn sie Anzeichen von Abnutzung oder Chemikaliendurchbruch aufweisen. Die Angaben bei Durchbruchzeit/Materialstärke sind Richtwerte! Die genaue Durchbruchzeit/Materialstärke ist beim Schutzhandschuhhersteller zu erfragen. Die Auswahl eines geeigneten Handschuhs ist nicht nur vom Material, sondern auch von weiteren Qualitätsmerkmalen abhängig und von Hersteller zu Hersteller unterschiedlich.

Eyes

Schutzbrille mit Seitenschutz gemäß EN 166

Respiratory

Bei Konzentrationen über den AGW-Werten ist ein entsprechendes, geprüftes Atemschutzgerät zu tragen. Atemschutzgerät mit Kombinationsfilter für Dämpfe und Partikel (EN 141) Beim Auftreten gefährlichen Rauchs umgebungsluftunabhängiges Atemschutzgerät tragen.

Skin/Body

Geeignete Schutzkleidung, z. B. aus Baumwolle oder hitzebeständiger Synthetikfaser tragen. Langärmelige Arbeitskleidung

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
flüssig
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
farblos
Colour Intensity
---
Form
---
Odor
beißend
Odor Threshold
---
Ph
4,7 (20 °C)
Melting Point
Nicht anwendbar
Boiling Point
Nicht anwendbar
Flash Point
61 °C, Methode: ISO 3679, geschlossener Tiegel
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Keine Daten verfügbar
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
ca. 1,1 g/cm³ (20 °C)
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
60 °C, Methode: Der Wert ist berechnet.
Solubility
---
Partition Coefficient
Keine Daten verfügbar
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Keine Daten verfügbar
Kinematic Viscosity
Keine Daten verfügbar
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabil unter angegebenen Lagerungsbedingungen. Keine Zersetzung bei bestimmungsgemäßer Lagerung und Anwendung.

Reactivity

Keine Zersetzung bei bestimmungsgemäßer Verwendung.

Hazardous reactions

Erwärmung kann Brand verursachen. Zersetzungsrisiko. Reagiert heftig im Kontakt mit Säuren, Aminen, Trocknungsmitteln, Polymerisationsbeschleunigern und leicht oxidierbaren Materialien.

Avoid

Temperatur < -10 °C, Vor Frost schützen, Temperatur > 30 °C, Zersetzt sich bei höheren Temperaturen, Extreme Temperaturen und direkte Sonneneinstrahlung, Kontakt mit nicht verträglichen Substanzen kann Zersetzung bei oder unterhalb der SADT hervorrufen, Von Hitze- und Zündquellen fernhalten.

Incompatible

Beschleuniger, starke Säure und Basen, Schwermetall(salze), Reduktionsmittel, Rost, Starke Oxidationsmittel, Starke Reduktionsmittel

Decomposition

Bei Brand und Zersetzung können reizende, ätzende, entzündbare, gesundheitsschädliche/ giftige Gase und Dämpfe entstehen. Kohlenstoffoxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxizität

Reaktionsmasse von Butan-2,2-diyl Dihydroperoxid und dioxydibutan-2,2-diyl Dihydroperoxid: Toxizität gegenüber Fischen : LC50 (Poecilia reticulata (Guppy)): 44,2 mg/l
Endpunkt: Mortalität
Expositionszeit: 96 h
Methode: Verordnung (EC) Nr. 440/2008, Anhang, C.1 Toxizität gegenüber Daphnien und anderen wirbellosen Wassertieren : EC50 (Daphnia magna (Großer Wasserfloh)): 39 mg/l
Expositionszeit: 48 h
Methode: Verordnung (EC) Nr. 440/2008, Anhang, C.2 Toxizität gegenüber Algen/Wasserpflanzen : EC50 (Pseudokirchneriella subcapitata (Grünalge)): 3,2 mg/l
Endpunkt: Biomasse
Expositionszeit: 72 h
Methode: Verordnung (EC) Nr. 440/2008, Anhang, C.3

12.1 Toxizität

Butanon: Toxizität gegenüber Fischen : LC50 (Pimephales promelas (fettköpfige Elritze)): 2.993 mg/l Endpunkt: Mortalität Expositionszeit: 96 h Methode: OECD Prüfrichtlinie 203 Toxizität gegenüber Daphnien und anderen wirbellosen Wassertieren : EC50 (Daphnia magna (Großer Wasserfloh)): 308 mg/l Endpunkt: Immobilisierung Expositionszeit: 48 h Methode: OECD- Prüfrichtlinie 202 Toxizität gegenüber Algen/Wasserpflanzen : EC50 (Pseudokirchneriella subcapitata (Grünalge)): 1.972 mg/l Expositionszeit: 72 h Methode: OECD- Prüfrichtlinie 201

Beurteilung Ökotoxizität

Chronische aquatische Toxizität: Schädlich für Wasserorganismen, mit langfristiger Wirkung.

Schädlich für Wasserorganismen, mit langfristiger Wirkung.

12.1 Toxizität

Toxizität gegenüber Fischen : LC50 (Danio rerio (Zebrabärbling)): 10 mg/l
Expositionszeit: 96 h Toxizität gegenüber Daphnien und anderen wirbellosen Wassertieren : EC50 (Daphnia magna (Großer Wasserfloh)): 8 mg/l
Expositionszeit: 48 h Toxizität gegenüber Algen/Wasserpflanzen : EC50 (Desmodesmus subspicatus (Grünalge)): 1,4 mg/l
Expositionszeit: 72 h Toxizität gegenüber Fischen (Chronische Toxizität) : NOEC: 315 mg/l
Expositionszeit: 28 d
Spezies: Danio rerio (Zebrabärbling)

12.2 Persistenz und Abbaubarkeit

12.2 Persistenz und Abbaubarkeit

12.2 Persistenz und Abbaubarkeit

Reaktionsmasse von Butan-2,2-diyl Dihydroperoxid und dioxydibutan-2,2-diyl Dihydroperoxid: Biologische Abbaubarkeit : Ergebnis: Leicht biologisch abbaubar
Methode: OECD- Prüfrichtlinie 301 B

12.3 Bioakkumulationspotenzial

Inhaltsstoffe: Reaktionsmasse von Butan-2,2-diyl Dihydroperoxid und dioxydibutan-2,2-diyl Dihydroperoxid: Verteilungskoeffizient: n- : log Pow: 2,04 (25 °C)

12.3 Bioakkumulationspotenzial

Butanon: Verteilungskoeffizient: n- : log Pow: 0,3 (40 °C) Octanol/Wasser pH-Wert: 7

12.3 Bioakkumulationspotenzial

Wasserstoffperoxid in Lösung: Verteilungskoeffizient: n- : log Pow: -1,57 (20 °C)

12.5 Ergebnisse der PBT- und vPvB-Beurteilung

Bewertung : Dieser Stoff/diese Mischung enthält keine Komponenten in Konzentrationen von 0,1 % oder höher, die entweder als persistent, bioakkumulierbar und toxisch (PBT) oder sehr persistent und sehr bioakkumulierbar (vPvB) eingestuft sind.

Dieser Stoff/diese Mischung enthält keine Komponenten in Konzentrationen von 0,1 % oder höher, die als PBT oder vPvB eingestuft sind.

12.6 Endokrinschädliche Eigenschaften

Bewertung : Der Stoff/dieses Gemisch enthält keine Bestandteile, die gemäß REACH Artikel 57(f) oder der delegierten Verordnung (EU) 2017/2100 der Kommission oder der delegierten Verordnung (EU) 2018/605 der Kommission in Mengen von 0,1 % oder mehr endokrinschädliche Eigenschaften aufweisen.

Der Stoff/dieses Gemisch enthält keine Bestandteile, die gemäß REACH Artikel 57(f) oder der delegierten Verordnung (EU) 2017/2100 der Kommission oder der delegierten Verordnung (EU) 2018/605 der Kommission in Mengen von 0,1 % oder mehr endokrinschädliche Eigenschaften aufweisen.

12.7 Andere schädliche Wirkungen

Sonstige ökologische Hinweise : Keine Daten verfügbar

Keine Daten verfügbar

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Abfälle getrennt sammeln. Nicht mit dem Hausmüll entsorgen. Nicht in die Kanalisation gelangen lassen; dieses Produkt und seinen Behälter der Problemabfallentsorgung zuführen. Unter Beachtung der örtlichen behördlichen Bestimmungen beseitigen.

Waste Codes

16 05 06 Laborchemikalien, die aus gefährlichen Stoffen bestehen oder solche enthalten, einschließlich Gemische von Laborchemikalien national code
16 09 03 Peroxide, z. B. Wasserstoffperoxid national code
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3105
Shipping Name
ORGANISCHES PEROXID TYP D, FLÜSSIG (Methylethylketonperoxid)
Transport Class
5.2
Packing Group
Nicht durch Verordnung festgelegt
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Das Produkt unterliegt den Abgabebeschränkungen der Chemikalienverbotsverordnung. Ausnahmeregelung gemäß §5 Abs. 4b der Chemikalienverbotsverordnung. Beschäftigungsbeschränkungen gemäß Richtlinie 94/33/EG über den Jugendarbeitsschutz oder verschärfenden nationalen Bestimmungen beachten, soweit zutreffend.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for UP-SYSTEM MEKP-Härter FL 505 SN?

The signal word is danger.

What is the physical form of UP-SYSTEM MEKP-Härter FL 505 SN?

UP-SYSTEM MEKP-Härter FL 505 SN is a flüssig with farblos color. It has beißend odor.

What is UP-SYSTEM MEKP-Härter FL 505 SN used for?

Härter

What are the hazard statements for UP-SYSTEM MEKP-Härter FL 505 SN?

This substance has 3 hazard statements:

  • H242: Erwärmung kann Brand verursachen.
  • H302 + H332: Gesundheitsschädlich bei Verschlucken oder Einatmen.
  • H314: Verursacht schwere Verätzungen der Haut und schwere Augenschäden.

What is the melting point of UP-SYSTEM MEKP-Härter FL 505 SN?

The melting point is Nicht anwendbar and the boiling point is Nicht anwendbar.