Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
DGT® SolventGlue EC.00 is a liquid substance commonly used industrial, professional, consumer, solvent action glue for the gluing of the polymethylmetacrylate (pmma)..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS07
GHS08
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H351: Suspected of causing cancer.
- H319: Causes serious eye irritation.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
Precautionary Statements
- P280: Wear protective gloves/ protective clothing / eye protection / face protection.
- P261: Avoid breathing dust / fume / gas / mist / vapours / spray.
- P201: Obtain special instructions before use.
- P312: Call a POISON CENTRE / doctor if you feel unwell.
- P403+P233: Store in a well-ventilated place. Keep container tightly closed.
- P264: Wash hands thoroughly after handling.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
DeskGlueTech S.r.l.
manufacturer
Via Edilizia 25/27, 20026 Novate Milanese, Italia (MI)
IT
+39 02 89767530
+39 02 89767530
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+43 14064343
AT
Emergency Contact
+32 070245245
BE
Emergency Contact
+359 29154233
BG
Emergency Contact
1401
CY
Emergency Contact
+45 82121212
DK
Emergency Contact
+34 915620420
ES
Emergency Contact
+385 12348342
HR
Emergency Contact
+372 7943794, 16662
EE
Emergency Contact
+358 800 147111
FI
Emergency Contact
+33 (0) 145425959
FR
Emergency Contact
112
DE
Emergency Contact
+30 2107793777
EL
Emergency Contact
+353 (01) 8092166
IE
Emergency Contact
+354 5432222, 112
IS
Emergency Contact
+371 67042473, 112
LV
Emergency Contact
+370 (85) 2362052
LT
Emergency Contact
+352 80025500
LU
Emergency Contact
2545 0000
MT
Emergency Contact
+47 22591300
NO
Emergency Contact
+31 (0) 887558000
NL
Emergency Contact
112
PL
Emergency Contact
+351 800250250
PT
Emergency Contact
+420 224919293
CZ
Emergency Contact
+40 212308000
RO
Emergency Contact
+421 254774166
SK
Emergency Contact
112
SI
Emergency Contact
112
SE
Emergency Contact
+36 80201199
HU
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
DICHLOROMETHANE EC: 200-838-9 | 75-09-2 | 80-90% | ⚠️ Hazardous |
NITROMETHANE EC: 200-876-6 | 75-52-5 | 10-20% | ⚠️ Hazardous |
CHLOROFORM EC: 200-663-8 | 67-66-3 | 0.1-1% | ⚠️ Hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
🫁 Inhalation Exposure
Remove to open air. If the subject stops breathing, administer artificial respiration. Get medical advice/attention immediately.
🖐️ Skin Contact
Remove contaminated clothing. Rinse skin with a shower immediately. Get medical advice/attention immediately. Wash contaminated clothing before using it again.
👁️ Eye Contact
Remove contact lenses, if present. Wash immediately with plenty of water for at least 15 minutes, opening the eyelids fully. If problem persists, seek medical advice.
🍽️ Ingestion/Swallowing
Get medical advice/attention immediately. Do not induce vomiting. Do not administer anything not explicitly authorised by a doctor.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
✅ Suitable Extinguishing Media
The extinguishing equipment should be of the conventional kind: carbon dioxide, foam, powder and water spray.
❌ Unsuitable Extinguishing Media
None in particular.
⚠️ Specific Fire Hazards
Do not breathe combustion products.
🔥 Fire Fighting Instructions
Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health. Always wear full fire prevention gear. Collect extinguishing water to prevent it from draining into the sewer system. Dispose of contaminated water used for extinction and the remains of the fire according to applicable regulations.
🛡️ Firefighter Protection Equipment
Normal fire fighting clothing i.e. fire kit (BS EN 469), gloves (BS EN 659) and boots (HO specification A29 and A30) in combination with self-contained open circuit positive pressure compressed air breathing apparatus (BS EN 137).
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
🚨 Emergency Procedures
Block the leakage if there is no hazard. Wear suitable protective equipment (including personal protective equipment referred to under Section 8 of the safety data sheet) to prevent any contamination of skin, eyes and personal clothing. These indications apply for both processing staff and those involved in emergency procedures.
🌍 Environmental Precautions
The product must not penetrate into the sewer system or come into contact with surface water or ground water.
🧹 Cleanup Methods
Absorb the remainder with inert absorbent material.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
⚠️ Handling Precautions
• Keep away from heat, sparks and naked flames; do not smoke or use matches or lighters.
• Without adequate ventilation, vapours may accumulate at ground level and, if ignited, catch fire even at a distance, with the danger of backfire.
• Avoid bunching of electrostatic charges.
• Do not eat, drink or smoke during use.
• Remove any contaminated clothes and personal protective equipment before entering places in which people eat.
• Avoid leakage of the product into the environment.
🏪 Storage Conditions
• Store only in the original container.
• Store in a cool and well ventilated place, keep far away from sources of heat, naked flames and sparks.
🧼 General Hygiene Measures
Do not eat, drink or smoke during use. Remove any contaminated clothes and personal protective equipment before entering places in which people eat.
🔥 Fire Prevention Measures
Keep away from heat, sparks and naked flames; do not smoke or use matches or lighters.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
🏭 Engineering Controls
Ensure that the workplace is well aired through effective local aspiration.
🧤 Hand Protection
Protect hands with category III work gloves (see standard EN 374). The following should be considered when choosing work glove material: compatibility, degradation, failure time and permeability.
👁️ Eye Protection
Wear airtight protective goggles (see standard EN 166).
😷 Respiratory Protection
If the threshold value (e.g. TLV-TWA) is exceeded for the substance or one of the substances present in the product, wear a mask with a type AX filter. In the presence of gases or vapours of various kinds and/or gases or vapours containing particulate, combined filters are required.
🦺 Skin/Body Protection
Wear category II professional long-sleeved overalls and safety footwear (see Regulation 2016/425 and standard EN ISO 20344). Wash body with soap and water after removing protective clothing.
🌍 Environmental Exposure Controls
The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with environmental standards.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
✅ Chemical Stability
The product is stable in normal conditions of use and storage.
⚗️ Reactivity
There are no particular risks of reaction with other substances in normal conditions of use. DICHLOROMETHANE decomposes at temperatures above 120℃/248ºF. With water and alkalis it may form hydrochloric acid and attack aluminium, copper and alloys.
⚠️ Hazardous Reactions
The vapours may also form explosive mixtures with the air. DICHLOROMETHANE risk of explosion on contact with: alkaline metals, nitric acid, aluminium powder, ethanediamine, aluminium chloride, perchloric acid, dinitrogen pentoxide, sodium nitride, n-nitroso n-methylurea, potassium hydroxide. May react dangerously with: alkaline earth metals, metal powders, sodium amides, potassium tert-butylate. May form explosive mixtures with: air.
🚫 Conditions to Avoid
Avoid overheating. Avoid bunching of electrostatic charges. Avoid all sources of ignition. DICHLOROMETHANE avoid exposure to: naked flames, overheated surfaces.
🧪 Incompatible Materials
DICHLOROMETHANE incompatible with: aluminium, magnesium, sodium, potassium, nitric acid, caustic substances, strong oxidants.
💨 Hazardous Decomposition Products
In the event of thermal decomposition or fire, gases and vapours that are potentially dangerous to health may be released. DICHLOROMETHANE may develop: dioxins, phosgenes, hydrochloric acid.
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
🌱 Toxicity
🌱 Persistence and degradability
🌱 Bioaccumulative potential
🌱 Mobility in soil
🌱 Results of PBT and vPvB assessment
🌱 Endocrine disrupting properties
🌱 Other adverse effects
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
♻️ Waste Treatment Methods
Reuse, when possible. Product residues should be considered special hazardous waste. The hazard level of waste containing this product should be evaluated according to applicable regulations.
🗂️ Product Disposal Recommendations
Disposal must be performed through an authorised waste management firm, in compliance with national and local regulations.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
🏷️ UN Number
1593
📦 Proper Shipping Name
DICHLOROMETHANE
⚠️ Transport Hazard Class
6.1
📋 Packing Group
III
🚛 ADR Transport Precautions
HIN - Kemler: 60; Special provision: 516
🚢 IMDG Maritime Transport Precautions
EMS: F-A, S-A
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
📋 Regulatory Summary
The product does not contain any SVHC in percentage ≥ than 0,1%.
❌ Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
ℹ️ Additional Regulatory Information
Workers exposed to this chemical agent must not undergo health checks, provided that available risk-assessment data prove that the risks related to the workers' health and safety are modest and that the 98/24/EC directive is respected.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for DGT® SolventGlue EC.00?
The signal word for this substance is "warning".
What is the physical form of DGT® SolventGlue EC.00?
DGT® SolventGlue EC.00 is a liquid appearing as liquid with colourless color. It has characteristic odor.
What is the solubility of DGT® SolventGlue EC.00?
soluble in water
What is DGT® SolventGlue EC.00 used for?
Industrial, Professional, Consumer, Solvent action glue for the gluing of the polymethylmetacrylate (PMMA).
What are the hazard statements for DGT® SolventGlue EC.00?
This substance has 4 hazard statements: H351: Suspected of causing cancer. H319: Causes serious eye irritation. H315: Causes skin irritation. H336: May cause drowsiness or dizziness.
What is the melting point of DGT® SolventGlue EC.00?
The melting point is < 0 ºC and the boiling point is > 40 ºC.