NextSDS Logo
2-

2-Amino-2-methyl-1-propanol

WARNING Low melting solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
2-Amino-2-methyl-1-propanol
Product Code
L07093
Chemical Name
2-amino-2-methylpropanol

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
SU24 Scientific research and development

Overview

2-Amino-2-methyl-1-propanol (CAS: 124-68-5 ) is a low melting solid substance commonly used su24 scientific research and development.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Irrit. Category 2 H315
Eye Irrit. Category 2A H319

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P280: Wear protective gloves.
  • P305+P351+P338: If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P337+P313: If eye irritation persists: Get medical advice/attention.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. company logo - Safety Data Sheet supplier organization

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

📍

30 Bond Street, Ward Hill, MA 01835-8099

🌍

US

📞

800-343-0660

📠

800-322-4757

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

800-343-0660

🕒

Monday-Friday, 8am-7pm EST

Carechem 24

📞

866-928-0789

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Chemical characterization: Substances

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2-amino-2-methylpropanol
EC: 204-709-8
124-68-5 100% ✓ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

🖐️ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

Symptoms:

Causes skin irritation.

👁️ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Symptoms:

Causes serious eye irritation.

🍽️ Ingestion/Swallowing

Seek medical treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Softening Point
Not available
📊 Explosive Limits
Not available
📊 Form
Low melting solid
📊 Odor Threshold
Not determined.
📊 Solidification Point
Not available
📊 Molecular Weight
Not available
⚖️ Density
0.934 g/cm3 (7.794 lbs/gal)
Critical Property
🔥 Flammability
Not applicable.
📊 Physical State Data
solid
📊 Solubility In Fat
Not available
👃 Odor
Amine-like
🧪 Ph
11.3
📊 Freezing Point
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
💨 Boiling Point
164-166 ℃ (327-331 °F)
Critical Property
📊 Vapor Density
Not applicable.
💨 Evaporation Rate
Not applicable.
📊 Upper Explosive Limit
Not determined
📊 Colour Intensity
Not available
📊 Properties Status
Not available
📊 Dynamic Viscosity
102 mPas
👁️ Appearance
Low melting solid
📊 Relative Density
Not determined.
📊 Auto Ignition Temperature
438 ℃ (820 °F)
🔥 Flash Point
67 °C (153 ºF)
Critical Property
📊 Cloud Point
Not available
🧊 Melting Point
24-28 ℃ (75-82 °F)
Critical Property
📊 Relative Evaporation Rate
Not available
📊 Kinematic Viscosity
Not applicable.
📊 Crystallisation Point
Not available
💨 Vapor Pressure
3.9 hPa (3 mm Hg)
💧 Solubility
Not available
📊 Partition Coefficient
Not determined.
📊 Solubility In Water
Soluble
🧪 Physical State
Low melting solid
Critical Property
📊 Decomposition Temperature
Not determined
📊 Bulk Density
Not available
📊 State Under Standard Conditions
Not available
📊 Lower Explosive Limit
Not determined
🎨 Colour
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

🧤 Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Butyl rubber, BR. Penetration time of glove material (in minutes) Not determined

👁️ Eye Protection

Safety glasses with side shields / NIOSH (US) or EN 166(EU)

😷 Respiratory Protection

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with type N95 (USA) or PE (EN 143) cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards. Use a respirator with organic vapor/acid gas cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

🦺 Skin/Body Protection

Protective work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

📦 Proper Shipping Name

Not applicable

⚠️ Transport Hazard Class

Not applicable

📋 Packing Group

Not applicable

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 2-Amino-2-methyl-1-propanol?

The signal word for this substance is "warning".

What is the physical form of 2-Amino-2-methyl-1-propanol?

2-Amino-2-methyl-1-propanol is a low melting solid appearing as low melting solid . It has amine-like odor.

What is 2-Amino-2-methyl-1-propanol used for?

SU24 Scientific research and development

What are the hazard statements for 2-Amino-2-methyl-1-propanol?

This substance has 2 hazard statements: H315: Causes skin irritation. H319: Causes serious eye irritation.

What is the melting point of 2-Amino-2-methyl-1-propanol?

The melting point is 24-28 ℃ (75-82 °F) and the boiling point is 164-166 ℃ (327-331 °F).