3-Pentanol
Product Code
L06065
Chemical Name
3-pentanol 603-200-00-1

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Overview

3-Pentanol (CAS: 584-02-1 ) is a characteristic substance .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Flam. Liq. Category 3 H226
Acute Tox. Category 4 H302
Acute Tox. Category 4 H332
Skin Irrit. Category 2 H315
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapor.
  • H302: Harmful if swallowed.
  • H315: Causes skin irritation.
  • H332: Harmful if inhaled.
  • H335: May cause respiratory irritation.

Precautionary Statements

  • P210: Keep away from heat/sparks/open flames/hot surfaces. No smoking.
  • P240: Ground/bond container and receiving equipment.
  • P241: Use explosion-proof electrical/ventilating/lighting/equipment.
  • P261: Avoid breathing dust/fume/gas/mist/vapors/spray
  • P280: Wear protective gloves / eye protection / face protection.
  • P301+P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
  • P303+P361+P353: If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
  • P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. company logo - Safety Data Sheet supplier organization

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

📍

30 Bond Street, Ward Hill, MA 01835-8099

🌍

US

📞

800-343-0660

📠

800-322-4757

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

(800) 343-0660

🕒

During normal business hours (Monday-Friday, 8am-7pm EST)

Carechem 24

📞

(866) 928-0789

🕒

After normal business hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Substances

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
3-pentanol 603-200-00-1
EC: 209-526-7
584-02-1 100% ✓ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Symptoms:

Harmful if inhaled.

🖐️ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

Symptoms:

Causes skin irritation.

👁️ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

🍽️ Ingestion/Swallowing

Seek medical treatment.

Symptoms:

Harmful if swallowed.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Softening Point
Not available
📊 Vapor Density
Not determined.
📊 Metal Corrosion
Not available
📊 Molecular Weight
Not available
📊 Freezing Point
Not available
👁️ Appearance
Characteristic
📊 Cloud Point
Not available
📊 Odor Threshold
Not determined.
📊 Physical State Data
liquid
📊 Dynamic Viscosity
Not determined.
🧪 Physical State
Liquid
Critical Property
📊 Partition Coefficient
Not determined.
📊 Voc Content
Not available
📊 Explosive Limits
Not available
📊 State Under Standard Conditions
Not available
📊 Crystallisation Point
Not available
💨 Evaporation Rate
Not determined.
📊 Decomposition Temperature
Not determined.
💨 Boiling Point
114-115 ℃ (237-239 ºF)
Critical Property
🔥 Flammability
Not determined.
📊 Colour Intensity
Not available
📊 Relative Density
Not determined.
📊 Upper Explosive Limit
8 Vol %
📊 Form
Liquid
🧊 Melting Point
-8 ℃ (18 °F)
Critical Property
📊 Solidification Point
Not available
📊 Kinematic Viscosity
Not determined.
💧 Solubility
Not available
🔥 Flash Point
33 °℃ (91 °F)
Critical Property
📊 Solubility In Water
55 g/l
⚖️ Density
0.817 g/cm3 (6.818 Ibs/gal)
Critical Property
🎨 Colour
Not available
💨 Vapor Pressure
11.69 hPa (9 mm Hg)
🧪 Ph
Not determined.
📊 Properties Status
Not available
📊 Bulk Density
Not available
📊 Solubility In Fat
Not available
👃 Odor
Characteristic
📊 Auto Ignition Temperature
Not determined.
📊 Lower Explosive Limit
1.2 Vol %
📊 Relative Evaporation Rate
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

🧤 Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Nitrile rubber, NBR. Penetration time of glove material (in minutes) 480. Glove thickness: 0.4 mm.

👁️ Eye Protection

Safety glasses with side shields / NIOSH (US) or EN 166(EU).

😷 Respiratory Protection

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with multi-purpose combination (US) or type ABEK (EN 14387) as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

🦺 Skin/Body Protection

Protective work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1105

📦 Proper Shipping Name

Pentanols

⚠️ Transport Hazard Class

3

📋 Packing Group

III

🚛 ADR Transport Precautions

Warning: Flammable liquids

🚢 IMDG Maritime Transport Precautions

Warning: Flammable liquids

✈️ IATA Air Transport Precautions

Warning: Flammable liquids

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 3-Pentanol?

The signal word for this substance is "warning".

What is the physical form of 3-Pentanol?

3-Pentanol is a liquid appearing as characteristic . It has characteristic odor.

What are the hazard statements for 3-Pentanol?

This substance has 5 hazard statements: H226: Flammable liquid and vapor. H302: Harmful if swallowed. H315: Causes skin irritation. H332: Harmful if inhaled. H335: May cause respiratory irritation.

What is the melting point of 3-Pentanol?

The melting point is -8 ℃ (18 °F) and the boiling point is 114-115 ℃ (237-239 ºF).