NextSDS Logo
Safety Data Sheet EN

N-Methylformamide

CAS 123-39-7
EC 204-624-6

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
N-Methylformamide
Product Code
L03908

Regulatory Identifiers

CAS Number
123-39-7 Check regulations →
EC Number
204-624-6 Check regulations →

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

800-343-0660

http://www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

Carechem 24

(866) 928-0789

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Repr. Cat. 1B H360
Acute Tox. Cat. 4 H312

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H312 Harmful in contact with skin.
H360 May damage fertility or the unborn child.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P281 Use personal protective equipment as required.
P302+P352 IF ON SKIN: Wash with plenty of water.
P308+P313 IF exposed or concerned: Get medical advice/attention.
P322 Specific measures (see on this label).
P363 Wash contaminated clothing before reuse.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Substances

Chemical Name CAS Number Concentration Hazardous
N-Methylformamide EC: 204-624-6 123-39-7 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Skin contact

Immediately wash with water and soap and rinse thoroughly. Seek immediate medical advice.

Symptoms: Harmful in contact with skin.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Chloroprene rubber, CR. Penetration time of glove material (in minutes) 480. Glove thickness 0.6 mm.

Eyes

Safety glasses.

Respiratory

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with multi-purpose combination (US) or type ABEK (EN 14387) as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
Not determined.
Freezing Point
---
Ph
Not determined.
Upper Explosive Limit
Not determined.
Solubility In Water
Not determined
Kinematic Viscosity
Not determined.
Crystallisation Point
---
Solubility
Not determined
Cloud Point
---
Auto Ignition Temperature
Not determined.
Dynamic Viscosity
Not determined.
Physical State Data
liquid
Solubility In Fat
---
Odor Threshold
Not determined.
Vapor Density
Not determined.
Flash Point
98 ℃ (208 °F)
Appearance
Not determined
Metal Corrosion
---
Physical State
Liquid
Colour
---
Bulk Density
---
Density
1.018 g/cm3 (8.495 lbs/gal)
Solidification Point
---
Boiling Point
181-185 ℃ (358-365 °F)
Flammability
Not determined.
Form
Liquid
Evaporation Rate
Not determined.
Softening Point
---
Molecular Weight
---
Voc Content
---
Decomposition Temperature
Not determined.
Odor
Not determined
Colour Intensity
---
Melting Point
-4 ℃ (25 °F)
State Under Standard Conditions
---
Relative Density
Not determined.
Properties Status
---
Lower Explosive Limit
Not determined.
Vapor Pressure
0.53 hPa
Relative Evaporation Rate
---
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Transport Class
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for N-Methylformamide?

The signal word is danger.

What is the physical form of N-Methylformamide?

N-Methylformamide is a liquid appearing as not determined . It has not determined odor.

What is the solubility of N-Methylformamide?

Not determined

What is N-Methylformamide used for?

SU24 Scientific research and development

What are the hazard statements for N-Methylformamide?

This substance has 2 hazard statements:

  • H312: Harmful in contact with skin.
  • H360: May damage fertility or the unborn child.

What is the melting point of N-Methylformamide?

The melting point is -4 ℃ (25 °F) and the boiling point is 181-185 ℃ (358-365 °F).