NextSDS Logo
Safety Data Sheet EN

Mesityl oxide

CAS 141-79-7
EC 205-502-5

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Mesityl oxide
Product Code
L05891

Regulatory Identifiers

CAS Number
141-79-7 Check regulations →
EC Number
205-502-5 Check regulations →

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

800-343-0660

www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

Carechem 24

(866) 928-0789

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226
Acute Tox. Cat. 4 H302
Acute Tox. Cat. 4 H312
Acute Tox. Cat. 4 H332

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H226 Flammable liquid and vapour.
H302 + H312 + H332 Harmful if swallowed, in contact with skin or if inhaled.

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P303 + P361 + P353 If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P403 + P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Chemical characterization: Substances

Chemical Name CAS Number Concentration Hazardous
Mesityl oxide EC: 205-502-5 141-79-7 --- No

4-Methyl-4-penten-2-one

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Seek immediate medical advice.

Skin contact

Immediately wash with water and soap and rinse thoroughly. Seek immediate medical advice.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

Immediate Medical Attention

Seek immediate medical advice; consult a doctor; seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, sand, extinguishing powder.

Unsuitable media

Do not use water.

Specific hazards

If this product is involved in a fire, the following can be released: Carbon monoxide and carbon dioxide

Firefighter Protection

Wear self-contained respirator. Wear fully protective impervious suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow material to be released to the environment without proper governmental permits.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep container tightly sealed. Ensure good ventilation at the workplace.

Storage

Store in cool, dry place in tightly closed containers. Keep container tightly sealed. Store in cool, dry conditions in well sealed containers.

Fire prevention

Keep ignition sources away.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Penetration time of glove material (in minutes) Not determined

Eyes

Safety glasses

Respiratory

Use suitable respirator when high concentrations are present.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
Not determined.
Colour
Colorless
Cloud Point
---
Decomposition Temperature
Not determined
Crystallisation Point
---
Partition Coefficient
Not determined.
Boiling Point
129-130 °C (264-266 °F)
Solidification Point
---
Odor Threshold
Not determined.
Bulk Density
---
Explosive Limits
---
Colour Intensity
---
Vapor Pressure
9.3 hPa (7 mm Hg)
Molecular Weight
---
Softening Point
---
Lower Explosive Limit
1.6 Vol %
Flammability
Not applicable.
Properties Status
---
Form
Oil
Solubility In Fat
---
Flash Point
30 °C (86 °F)
Relative Evaporation Rate
---
Physical State
Oil
Melting Point
-59 °C (-74 °F)
Physical State Data
liquid
Metal Corrosion
---
Evaporation Rate
Not determined.
Voc Content
---
Auto Ignition Temperature
344 °C (651 °F)
Ph
Not determined.
Density
0.856 g/cm³ (7.143 lbs/gal)
Odor
Not determined
Solubility
---
Solubility In Water
30 g/l
Dynamic Viscosity
Not determined.
State Under Standard Conditions
---
Kinematic Viscosity
Not determined.
Freezing Point
---
Appearance
Oil
Relative Density
Not determined.
Upper Explosive Limit
Not determined
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No information known.

Hazardous reactions

No dangerous reactions known

Avoid

No further relevant information available.

Incompatible

Oxidizing agents

Decomposition

Carbon monoxide and carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Consult state, local or national regulations to ensure proper disposal.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1229
Shipping Name
Mesityl oxide
Transport Class
3
Packing Group
III
ADR

Warning: Flammable liquids

IMDG

Warning: Flammable liquids

IATA

Warning: Flammable liquids

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

For use only by technically qualified individuals.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Mesityl oxide?

The signal word is warning.

What is the physical form of Mesityl oxide?

Mesityl oxide is a oil appearing as oil with colorless color. It has not determined odor.

What is Mesityl oxide used for?

SU24 Scientific research and development

What are the hazard statements for Mesityl oxide?

This substance has 2 hazard statements:

  • H226: Flammable liquid and vapour.
  • H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled.

What is the melting point of Mesityl oxide?

The melting point is -59 °C (-74 °F) and the boiling point is 129-130 °C (264-266 °F).