EPTC
Product Code
45469
Chemical Name
EPTC

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Laboratory chemicals, Manufacture of substances

Overview

EPTC (CAS: 759-94-4 ) is a colourless substance commonly used laboratory chemicals, manufacture of substances.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Acute Tox. Category 4 H302
Acute Tox. Category 4 H312
Aquatic Acute Category 2 H401
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed or in contact with skin
  • H312: Harmful if swallowed or in contact with skin
  • H411: Toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P264: Wash skin thoroughly after handling.
  • P270: Do not eat, drink or smoke when using this product.
  • P273: Avoid release to the environment.
  • P280: Wear protective gloves/ protective clothing.
  • P301+P312: IF SWALLOWED: Call a POISON CENTER or doctor/ physician if you feel unwell.
  • P302+P352: IF ON SKIN: Wash with plenty of soap and water.
  • P312: Call a POISON CENTER or doctor/ physician if you feel unwell.
  • P322: Specific measures (see supplemental first aid instructions on this label).
  • P330: Rinse mouth.
  • P363: Wash contaminated clothing before reuse.
  • P391: Collect spillage.
  • P501: Dispose of contents/ container to an approved waste disposal plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma-Aldrich

manufacturer

πŸ“

3050 Spruce Street, SAINT LOUIS MO 63103, USA

🌍

US

πŸ“ž

+1 800-325-5832

πŸ“ 

+1 800-325-5052

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

πŸ“ž

+1-703-527-3887

🌍

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
EPTC
EC: 212-073-8
759-94-4 Not specified ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

πŸ–οΈ Skin Contact

Wash off with soap and plenty of water. Consult a physician.

πŸ‘οΈ Eye Contact

Flush eyes with water as a precaution.

🍽️ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
liquid
Critical Property
πŸ“Š Physical State Data
liquid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
colourless
🎨 Colour
colourless
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
liquid
πŸ‘ƒ Odor
no data available
πŸ“Š Odor Threshold
no data available
πŸ§ͺ Ph
no data available
🧊 Melting Point
no data available
Critical Property
πŸ’¨ Boiling Point
127 Β°C (261 ΒΊF) at 27.00 hPa (20.25 mmHg)
Critical Property
πŸ”₯ Flash Point
> 100 Β°C (> 212 Β°F)
Critical Property
πŸ“Š Freezing Point
no data available
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
no data available
πŸ’¨ Vapor Pressure
0.032 hPa (0.024 mmHg) at 25 Β°C (77 ΒΊF)
πŸ“Š Vapor Density
no data available
πŸ“Š Relative Density
0.955 g/cm3 at 20 Β°C (68 ΒΊF)
πŸ“Š Bulk Density
0.955 g/l at 30 Β°C (86 Β°F)
βš–οΈ Density
Not available
πŸ”₯ Flammability
no data available
πŸ“Š Upper Explosive Limit
no data available
πŸ“Š Lower Explosive Limit
no data available
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
no data available
πŸ“Š Decomposition Temperature
no data available
πŸ’§ Solubility
insoluble
πŸ“Š Partition Coefficient
log Pow: 3.21
πŸ“Š Solubility In Water
insoluble
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Kinematic Viscosity
Not available
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

🧀 Hand Protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

πŸ‘οΈ Eye Protection

Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

😷 Respiratory Protection

Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

🌍 Environmental Exposure Controls

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for EPTC?

The signal word for this substance is "warning".

What is the physical form of EPTC?

EPTC is a liquid appearing as colourless with colourless color. It has no data available odor.

What is the solubility of EPTC?

insoluble

What is EPTC used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for EPTC?

This substance has 3 hazard statements: H302: Harmful if swallowed or in contact with skin H312: Harmful if swallowed or in contact with skin H411: Toxic to aquatic life with long lasting effects.

What is the melting point of EPTC?

The melting point is no data available and the boiling point is 127 Β°C (261 ΒΊF) at 27.00 hPa (20.25 mmHg).