Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Boron Nitride Coatings
- Product Code
- SF+, 10SF+
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial uses.
Uses advised against
Not intended for food and drug use.
Manufacturers & Suppliers
INSULCON B.V.
Zilverhoek 4, 4651 SP STEENBERGEN, The Netherlands
+31 (0)167-565750
http://www.insulcon.com
INSULCON N.V.
Belgium
+32 (0)3 711.02.78
INSULCON GMBH
Germany
+49 (0) 2162 249 60-0
Emergency Contacts
INSULCON B.V.
+31 (0)167-565750
INSULCON N.V.
+ 32 (0)3 711.02.78
INSULCON GMBH
+ 49 (0) 2162 249 60-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Hexagonal Boron Nitride and Aluminium Oxide
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hexagonal Boron Nitride EC: 233-136-6 | 10043-11-5 | 4 - 35% | No |
| Aluminium Oxide EC: 215-691-6 | 1344-28-1 | 15% | No |
For the wording of the listed hazard phrases refer to section 16.
Notes
The identity and/or exact percentages are being withheld as a trade secret.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately rinse with water. If skin irritation is experienced, consult a doctor.
Remove contact lenses if worn, if possible. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Rinse out mouth and then drink plenty of water. Do not induce vomiting; call for medical help immediately.
Symptoms: Gastro-intestinal irritation, Nausea, Diarrhea, Vomiting.
Immediate Medical Attention
Call for medical help immediately (if swallowed).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product is not flammable. Use fire extinguishing methods suitable to surrounding conditions.
None.
No further relevant information available.
Firefighter Protection
Wear self-contained respiratory protective device. Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid release to the environment.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well ventilated areas. Avoid splashes or spray in enclosed areas. Avoid breathing mist/vapours/spray. Wash hands before breaks and at the end of work.
Store in cool, dry conditions in well-sealed receptacles. Use only receptacles specifically permitted for this substance/product.
Wash hands before breaks and at the end of work.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gloves are advised for repeated or prolonged contact. Wear protective gloves to handle contents of damaged or leaking units.
Safety glasses
Not required under normal conditions of use. Use suitable respiratory protective device when aerosol or mist is formed. For large spills, respiratory protection may be advisable.
Protective work clothing. Protection may be required for spills.
Avoid release to the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No further relevant information available.
Reacts with alkali (lyes).
No further relevant information available.
Oxidisers, strong acids.
Under fire conditions only: Nitrogen oxides (NOx), Toxic metal oxide smoke
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The user of this material has the responsibility to dispose of unused material, residues and containers in compliance with all relevant local, state and federal laws and regulations regarding treatment, storage and disposal for hazardous and non-hazardous wastes.
The user of this material has the responsibility to dispose of unused material, residues and containers in compliance with all relevant local, state and federal laws and regulations regarding treatment, storage and disposal for hazardous and non-hazardous wastes.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Not Regulated
- Transport Class
- Not Regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Boron Nitride Coatings?
The signal word is no signal word.
What is the physical form of Boron Nitride Coatings?
Boron Nitride Coatings is a liquid appearing as liquid, white with white color. It has odourless odor.
What is the solubility of Boron Nitride Coatings?
Partly miscible
What is Boron Nitride Coatings used for?
Industrial uses.
What is the melting point of Boron Nitride Coatings?
The melting point is Not determined. and the boiling point is 100 °C (212 °F) (water).