Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Barium titanate(IV)
- Product Code
- CO3672
Regulatory Identifiers
- CAS Number
- 12047-27-7 Check regulations →
Identified Uses
For R&D use only. Not for pharmaceutical, household or other uses.
Uses advised against
Not for pharmaceutical, household or other uses.
Manufacturers & Suppliers
Stanford Advanced Materials
manufacturer
23661 Birtcher Dr. Lake Forest, CA 92630 USA
+1 (949) 407-8904
Emergency Contacts
Emergency Contact
+1 (949) 407-8904
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| barium titanate(IV) EC: 234-975-0 | 12047-27-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. If breathing stops: mouth-to-mouth breathing or artificial respiration. Oxygen if necessary. Immediately call in physician.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Immediate Medical Attention
Immediately call in physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Titanium/titanium oxides, Barium oxide. Ambient fire may liberate hazardous vapours.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture.
Tightly closed. Dry.
Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested:Dermatril® (KCL 740 / Aldrich Z677272, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374. If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature) .
no information available
no information available
Strong oxidizing agents
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Offer surplus and non-recyclable solutions to a licensed disposal company.
Offer surplus and non-recyclable solutions to a licensed disposal company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Not dangerous goods
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Please pay attention on the waste treatment should also comply with local regulations requirement.
Please pay attention on the waste treatment should also comply with local regulations requirement.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Barium titanate(IV)?
The signal word is warning.
What is the physical form of Barium titanate(IV)?
Barium titanate(IV) is a powder with light green color. It has no data available odor.
What is Barium titanate(IV) used for?
For R&D use only. Not for pharmaceutical, household or other uses.
What are the hazard statements for Barium titanate(IV)?
This substance has 3 hazard statements:
- H302: Harmful if swallowed.
- H302 + H332: Harmful if swallowed or if inhaled.
- H332: Harmful if inhaled.
What is the melting point of Barium titanate(IV)?
The melting point is Melting point/range: 21.8 - 42 °C and the boiling point is No data available.