NextSDS Logo
UL

ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE

NO SIGNAL WORD solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Polymer, for industrial processing only

Overview

ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE is a granules substance commonly used polymer, for industrial processing only.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BASF Vietnam Co. Ltd.

manufacturer

📍

Level 23, Deutsches Haus, 33 Le Duan, Ben Nghe Ward, Dist. 1, Ho Chi Minh City, Vietnam

🌍

VN

📞

+84 28 3824 3833

📠

+84 28 3824 3832

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

18001703

🌍

VN

Emergency Contact

📞

+49 180 2273-112

🌍

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Preparation based on polybutylene terephthalate (PBT), additives, fillers

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

remove to fresh air and seek medical attention.

Symptoms:

difficulties occur after dust has been inhaled

🖐️ Skin Contact

Wash thoroughly with soap and water. Burns caused by molten material require hospital treatment.

Symptoms:

Burns caused by molten material

👁️ Eye Contact

rinse immediately for at least 15 minutes with plenty of water. If irritation develops, seek medical attention.

Symptoms:

irritation develops

🍽️ Ingestion/Swallowing

Rinse mouth and then drink 200-300 ml of water. If difficulties occur: Seek medical attention.

Symptoms:

difficulties occur

🚨 Immediate Medical Attention Required

Seek medical attention.

Medical Treatment

Treat according to symptoms (decontamination, vital functions), no known specific antidote.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
solid
Critical Property
📊 Lower Explosive Limit
Not available
📊 Partition Coefficient
not applicable
📊 Explosive Limits
Not available
📊 Upper Explosive Limit
For solids not relevant for classification and labelling.
🎨 Colour
various, depending on the colourant
📊 Auto Ignition Temperature
350 ℃
👁️ Appearance
granules
📊 Colour Intensity
Not available
📊 Kinematic Viscosity
not applicable, the product is a solid
📊 Relative Density
1.3 - 1.8 g/cm3 (20 °℃, 1,013 hPa)
📊 Molecular Weight
Not available
🧊 Melting Point
220 - 230 ℃
Critical Property
📊 Softening Point
Not available
⚖️ Density
Not available
📊 State Under Standard Conditions
Not available
💨 Evaporation Rate
The product is a non-volatile solid.
📊 Relative Evaporation Rate
Not available
📊 Dynamic Viscosity
not applicable, the product is a solid
📊 Metal Corrosion
Not available
📊 Cloud Point
Not available
📊 Bulk Density
600 - 900 kg/m3 (20 ℃, 1,013 hPa)
🔥 Flammability
not self-igniting
📊 Voc Content
Not available
📊 Freezing Point
Not available
📊 Decomposition Temperature
> 290 ℃
🧪 Ph
not applicable
👃 Odor
odourless
💨 Vapor Pressure
not applicable
💧 Solubility
insoluble (20 ℃, 1,013 hPa)
📊 Solubility In Fat
Not available
🔥 Flash Point
not applicable
Critical Property
📊 Vapor Density
Not available
📊 Odor Threshold
not applicable
📊 Physical State Data
solid
📊 Form
granules
📊 Crystallisation Point
Not available
📊 Solidification Point
Not available
📊 Solubility In Water
insoluble (20 ℃, 1,013 hPa)
💨 Boiling Point
Not available
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🧤 Hand Protection

Use additional heat protection gloves when handling hot molten masses (EN 407), e.g. of textile or leather.

👁️ Eye Protection

Safety glasses with side-shields (frame goggles) (e.g. EN 166)

😷 Respiratory Protection

Breathing protection if breathable aerosols/dust are formed. Wear respiratory protection if ventilation is inadequate. (Particle filter EN 143 P2 or FFP2)

🦺 Skin/Body Protection

Body protection must be chosen depending on activity and possible exposure, e.g. apron, protecting boots, chemical-protection suit (according to EN 14605 in case of splashes or EN ISO 13982 in case of dust).

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE?

The signal word for this substance is "no signal word".

What is the physical form of ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE?

ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE is a solid appearing as granules with various, depending on the colourant color. It has odourless odor.

What is the solubility of ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE?

insoluble (20 ℃, 1,013 hPa)

What is ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE used for?

Polymer, for industrial processing only

What is the melting point of ULTRADUR® B 4300 G6 BK Q16 15007 POLYBUTYLENE TEREPHTHALATE?

The melting point is 220 - 230 ℃ .