NextSDS Logo
Safety Data Sheet EN

Nickel Cadmium Rechargeable Battery Pack

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Nickel Cadmium Rechargeable Battery Pack

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

M

Makita U.S.A., Inc.

manufacturer

14930-C Northam Street, La Mirada, CA 90638

1-510-657-9881

Emergency Contacts

CHEMTREC

1-800-424-9300

Day or Night

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The product is a manufactured article as described in 29 CFR 1910.1200. The battery cell, chemical materials are stored in a hermetically-sealed metal case, designed to withstand temperatures and pressures encountered during normal use. As a result, during normal use, there is no physical danger of ignition or explosion and chemical danger of hazardous materials leakage. However, if exposed to a fire, explosion, added mechanical shocks, decomposed, added electric stress by misuse, the gas release vent will be operated. The battery cell case will be breached at the extreme. Hazardous materials may be released. Moreover, if heated intensely by the surrounding fire, acid or harmful fume may be emitted.

Chemical Name CAS Number Concentration Hazardous
Nickel, Nickel Compounds 7440-02-0 15 - 40% Yes
Cadmium, Cadmium Compounds 7440-43-9 10 - 40% Yes
Cobalt Compounds 7440-48-4 3% Yes
Carbon Black 1333-86-4 1% Yes
Iron 7439-89-6 20 - 65% No
Potassium Hydroxide 1310-58-3 5% Yes
Sodium Hydroxide 1310-73-2 5% Yes
Lithium Hydroxide 1310-65-2 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Cover the victim in a blanket, move to the place of fresh air and keep quiet. Give artificial respiration immediately if breathing difficulty or asphyxia occurs.

Symptoms: Dyspnea (breathing difficulty), asphyxia (short of oxygen).

Skin contact

Remove contaminated clothes and shoes immediately. Wash the contacted region with soap and plenty of water. Seek medical attention immediately.

Eye contact

Immediately flush eyes with water continuously for at least 15 minutes. Seek medical attention immediately.

Ingestion

If a battery cell and internal cell materials of an opened battery cell are ingested, do not induce vomiting. Seek medical attention immediately.

Immediate Medical Attention

Seek medical attention immediately for all exposure routes.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No engineering measure is necessary during normal use. In case of internal cell materials' leakage, the information below will be useful

Hands

Protective gloves

Eyes

Protective glasses designed to protect against liquid splashes

Respiratory

Protective mask

Skin/Body

Working clothes with long sleeve and long trousers

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Dynamic Viscosity
---
Vapor Pressure
---
Voc Content
---
Physical State
Solid
Metal Corrosion
---
Upper Explosive Limit
---
Odor
No odor
Melting Point
---
Colour Intensity
---
Solubility In Fat
---
Solubility
Insoluble in water
Relative Evaporation Rate
---
Vapor Density
---
Flammability
---
Appearance
Cylindrical
State Under Standard Conditions
---
Evaporation Rate
---
Form
Cylindrical
Partition Coefficient
---
Density
About 2.4 ~ 4. 0g/cm3
Flash Point
---
Cloud Point
---
Relative Density
---
Properties Status
---
Bulk Density
---
Freezing Point
---
Explosive Limits
---
Physical State Data
solid
Solidification Point
---
Boiling Point
---
Colour
Metallic color (without tube)
Molecular Weight
---
Ph
---
Decomposition Temperature
---
Solubility In Water
Insoluble in water
Softening Point
---
Odor Threshold
---
Lower Explosive Limit
---
Crystallisation Point
---
Kinematic Viscosity
---
Auto Ignition Temperature
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Nickel Cadmium Rechargeable Battery Pack?

The signal word is no signal word.

What is the physical form of Nickel Cadmium Rechargeable Battery Pack?

Nickel Cadmium Rechargeable Battery Pack is a solid appearing as cylindrical with metallic color (without tube) color. It has no odor odor.

What is the solubility of Nickel Cadmium Rechargeable Battery Pack?

Insoluble in water