NextSDS Logo
Ni

Nickel Metal Hydride Battery

NO SIGNAL WORD Solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Nickel Metal Hydride Battery

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

Nickel Metal Hydride Battery .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Makita U.S.A., Inc.

manufacturer

๐Ÿ“

14930-C Northam Street, La Mirada, CA 90638

๐ŸŒ

US

๐Ÿ“ž

1-510-657-9881

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

1-800-424-9300

๐ŸŒ

US

๐Ÿ’ก

For Chemical Emergency Spills, Leak, Fire, Exposure, or Accident

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Preparation information about the chemical nature of product

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrogen Absorbing Alloy N/A 20-40% โš ๏ธ Hazardous
Nickel-Cobalt-Zinc Oxide N/A 15-25% โš ๏ธ Hazardous
Nickel 74420-02-0 5-15% โš ๏ธ Hazardous
Iron [Fe]
EC: 231-096-4
7439-89-6 20-40% โœ“ Non-hazardous
carbon black
EC: 215-609-9
1333-86-4 1% โš ๏ธ Hazardous
Kaliumhydroxide; bijtende potas
EC: 215-181-3
1310-58-3 15% โš ๏ธ Hazardous
Natriumhydroxide Oplossing
EC: 215-185-5
1310-73-2 15% โš ๏ธ Hazardous
Lithiumhydroxide
EC: 215-183-4
1310-65-2 15% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Cover the victim in a blanket, move to the place of fresh air and keep quiet. Give artificial respiration immediately if needed.

Symptoms:

Breathing difficulty, asphyxia.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothes and shoes immediately. Wash the adherence or contact region with soap and plenty of water. Seek medical attention immediately.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with water continuously for at least 15 minutes. Seek medical attention immediately.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting. Seek medical attention immediately.

๐Ÿšจ Immediate Medical Attention Required

Seek medical attention immediately for any exposure.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Metallic color (without tube/label)
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Cylindrical and Prismatic
๐Ÿ‘ƒ Odor
No odor
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Around 1.5 ~6.0g/cm3
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Insoluble in water:
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Insoluble in water:
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No engineering measure is necessary during normal use. In case of internal cell materials' leakage, the information below will be useful.

๐Ÿงค Hand Protection

Protective gloves

๐Ÿ‘๏ธ Eye Protection

Protective glasses designed to protect against liquid splashes

๐Ÿ˜ท Respiratory Protection

Protective mask

๐Ÿฆบ Skin/Body Protection

Working clothes with long sleeve and long trousers

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Nickel Metal Hydride Battery?

The signal word for this substance is "no signal word".

What is the physical form of Nickel Metal Hydride Battery?

Nickel Metal Hydride Battery is a solid with metallic color (without tube/label) color. It has no odor odor.

What is the solubility of Nickel Metal Hydride Battery?

Insoluble in water: