Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MicroMB-FL 1014-T50
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Manufacture of plastics products
Manufacturers & Suppliers
Sanita Consumer Products – Masterpaknile –
national supplier
6th industrial zone - Sadat – Menofiya, Egypt
http://www.micromb.com
Emergency Contacts
Emergency Contact
+20482614996
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH annex
Notes
This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH annex
First Aid Measures
Emergency procedures for chemical exposure incidents
Material is not likely to be hazardous. If exposed to high amount of fumes formed at elevated temperatures, remove to fresh air; administer artificial respiration if breathing is stopped. Get medical attention if cough or other symptoms appear.
Symptoms: irritation of the respiratory system
For hot product, immediately immerse or flash affected area with large amounts of cold water to dissipate heat. Cover with clean cotton sheeting or sterilized gauze and get prompt medical attention. No attempt should be made to remove material from skin or to remove contaminated clothing, as the damaged flesh can be easily torn.
Symptoms: The melted product can cause severe burns.
Not likely to be an eye hazard in the present form. If in eye, remove as for any foreign object by flushing with water. If irritation occurs, obtain medical attention.
IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
Medical Treatment
treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, foam, carbon dioxide or skilled use of water spray.
Fire hazard: Thermal decomposition can lead to the escape of irritating gases and vapours.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For non-emergency personnel: use Protective equipment: Wear suitable protective clothing. follow safe handling advice and personal protective equipment recommendations.
Do not allow uncontrolled leakage of product into the environment.
Remove mechanically, placing in appropriate containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid generation of dust. Provide adequate ventilation. Remove all sources of ignition. Take precautionary measures against static discharges. When using do not eat, drink or smoke.
Keep container tightly closed and dry.
When using do not eat, drink or smoke.
Remove all sources of ignition. Take precautionary measures against static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If suction of the immediate vicinity is impossible or insufficient, the entire working place must be sufficiently ventilated using appropriate machines.
Wear suitable gloves
Wear eye/face protection
No personal respiratory protective equipment normally required
Only wear fitting, comfortable and clean protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of use.
None under normal conditions.
None known.
Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
Oxidizing agents.
In case of fire: Carbon monoxide. Carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product is not classified as dangerous according to EC criteria.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MicroMB-FL 1014-T50?
The signal word is no signal word.
What is the physical form of MicroMB-FL 1014-T50?
MicroMB-FL 1014-T50 is a solid appearing as granules. with white / grey color. It has odourless odor.
What is the solubility of MicroMB-FL 1014-T50?
insoluble
What is MicroMB-FL 1014-T50 used for?
Manufacture of plastics products
What is the melting point of MicroMB-FL 1014-T50?
The melting point is > 120°C and the boiling point is Decomposes before boiling.