Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Elevate EPDM Solvent Free Bonding Adhesive
- Product Code
- W563587029
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Sealant.
Uses advised against
None known.
Manufacturers & Suppliers
Holcim Solutions and Products US, LLC
distributor
26 Century Boulevard, Suite 205 Nashville, TN 37214
1-800-428-4442
holcimelevate.com
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
+1 703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Aminopropyltrimethoxysilane | 13822-56-5 | 1 - 5% | No |
| Dibutyltin bis(acetylacetonate) | 22673-19-4 | 1% | No |
Notes
All concentrations are in percent by weight unless otherwise indicated. Components not listed are either non-hazardous or are below reportable limits.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Call a physician if symptoms develop or persist.
Remove contaminated clothing immediately and wash skin with soap and water. In case of eczema or other skin disorders: Seek medical attention and take along these instructions.
Symptoms: May cause an allergic skin reaction. Dermatitis. Rash.
Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately.
Symptoms: Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision. Permanent eye damage including blindness could result.
Rinse mouth. Get medical attention if symptoms occur.
Immediate Medical Attention
Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed.
Medical Treatment
Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station.
Wear appropriate chemical resistant gloves. Examples of preferred glove barrier materials include: Nitrile. Suitable gloves can be recommended by the glove supplier.
Wear safety glasses with side shields (or goggles).
If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn. Chemical respirator with organic vapor cartridge and full facepiece. Appropriate respirator selection should be made by a qualified professional.
Wear appropriate chemical resistant clothing. Use of an impervious apron is recommended.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
May react with water liberating a small amount of methanol.
No dangerous reaction known under conditions of normal use.
Contact with incompatible materials.
Acids. Strong oxidizing agents. Fluorine.
Thermal decomposition or combustion may produce: Carbon oxides. Silicon oxides. Nitrogen oxides. Formaldehyde.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Elevate EPDM Solvent Free Bonding Adhesive?
The signal word is danger.
What is the physical form of Elevate EPDM Solvent Free Bonding Adhesive?
Elevate EPDM Solvent Free Bonding Adhesive is a liquid. appearing as liquid. with not available. color. It has mild. odor.
What is Elevate EPDM Solvent Free Bonding Adhesive used for?
Sealant.
What are the hazard statements for Elevate EPDM Solvent Free Bonding Adhesive?
This substance has 4 hazard statements:
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H412: Harmful to aquatic life with long lasting effects.
- May damage fertility or the unborn child.
What is the melting point of Elevate EPDM Solvent Free Bonding Adhesive?
The melting point is Not determined. and the boiling point is > 392 °F (> 200 °C).