NextSDS Logo
Safety Data Sheet EN

Bonding Liquid Floor Leveler Additive

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Bonding Liquid Floor Leveler Additive

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Concrete Bonding Additive

Manufacturers & Suppliers

D

DAP Global Inc.

manufacturer

2400 Boston Street Suite 200, Baltimore, MD 21224-4723

888-327-8477

Emergency Contacts

Medical/Poison Control

1-800-222-1222

Transportation/National Response Center

1-800-535-5053

Transportation/National Response Center

1-352-323-3500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.

Skin contact

Wash off with soap and water.

Eye contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes.

Ingestion

If swallowed, DO NOT INDUCE VOMITING.

Immediate Medical Attention

Get medical attention immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog, Water

Specific hazards

No Information

Instructions

Use water spray to cool exposed surfaces.

Firefighter Protection

Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Contain spilled material and remove with inert absorbent. Dispose of contaminated absorbent, container and unused contents in accordance with local, state and federal regulations. Dike to prevent entering any sewer or waterway. In case of spillage, absorb with inert material and dispose of in accordance with applicable regulations.

Environmental

No Information

Cleanup methods

remove with inert absorbent. absorb with inert material

Materials: inert absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

KEEP OUT OF REACH OF CHILDREN! Use in well ventilated area. Provide fresh air such that chemical odors cannot be detected during use and while drying. Avoid prolonged or repeated contact with skin. Avoid contact with eyes. Construction and repair activities can adversely affect indoor air quality. Consult with occupants or a representative (i.e. maintenance, building manager, industrial hygienist, or safety officer) to determine ways to minimize impact.

Storage

Avoid excessive heat and freezing. Keep containers closed when not in use. Do not store at temperatures above 120 °F (49 °C). Store away from caustics and oxidizers.

Hygiene

Avoid prolonged or repeated contact with skin. Avoid contact with eyes.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Wear gloves with repeated or prolonged use.

Eyes

Goggles or safety glasses with side shields.

Respiratory

No personal respiratory protective equipment normally required. If concentrations exceed the exposure limits specified, use of a NIOSH-approved supplied air respirator is recommended. Where the protection factor is exceeded, use of a Self Contained Breathing Apparatus (SCBA) may be necessary.

Skin/Body

Not required under normal use.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
---
Explosive Limits
---
Form
---
Decomposition Temperature
Not Established
Kinematic Viscosity
---
Metal Corrosion
---
Molecular Weight
---
Physical State
Liquid
Solubility
---
Boiling Point
100 - 100 °C
Physical State Data
liquid
Freezing Point
Not Established
Solidification Point
---
Upper Explosive Limit
N.E.
State Under Standard Conditions
---
Dynamic Viscosity
Not Established
Auto Ignition Temperature
Not Established
Appearance
Opaque
Vapor Density
Heavier Than Air
Melting Point
---
Crystallisation Point
---
Lower Explosive Limit
N.E.
Bulk Density
---
Solubility In Fat
---
Properties Status
---
Colour Intensity
---
Odor Threshold
Not Established
Density
1.03 - 1.03 g/cm3
Softening Point
---
Relative Evaporation Rate
---
Voc Content
---
Colour
---
Partition Coefficient
Not Established
Flammability
Non-Flammable
Flash Point
100 °C (Seta Closed Cup)
Cloud Point
---
Vapor Pressure
Not Established
Evaporation Rate
Slower Than n-Butyl Acetate
Solubility In Water
Not Established
Ph
Between 7.0 and 12.0
Odor
Slight
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Avoid

Excessive heat and freezing.

Incompatible

Strong oxidizing agents. Strong bases.

Decomposition

Normal decomposition products, i.e., COx, NOx.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Bonding Liquid Floor Leveler Additive?

The signal word is no signal word.

What is the physical form of Bonding Liquid Floor Leveler Additive?

Bonding Liquid Floor Leveler Additive is a liquid appearing as opaque . It has slight odor.

What is Bonding Liquid Floor Leveler Additive used for?

Concrete Bonding Additive