NextSDS Logo
Safety Data Sheet EN

Concrete Bonding Additive

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Concrete Bonding Additive
Product Code
4000501

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Concrete Bonding Additive

Manufacturers & Suppliers

D

DAP Global Inc.

manufacturer

2400 Boston Street Suite 200, Baltimore, MD 21224-4723

888-327-8477

Emergency Contacts

Transportation

1-800-535-5053

Transportation

1-352-323-3500

Poison Control

1-800-222-1222

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Ethylene glycol 107-21-1 1 - 5% Yes
Vinyl acetate 108-05-4 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.

Skin contact

Wash off with soap and water.

Eye contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes.

Ingestion

If swallowed, DO NOT INDUCE VOMITING.

Immediate Medical Attention

Get medical attention immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog, Water

Instructions

Use water spray to cool exposed surfaces.

Firefighter Protection

Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Contain spilled material and remove with inert absorbent. Dispose of contaminated absorbent, container and unused contents in accordance with local, state and federal regulations. Dike to prevent entering any sewer or waterway. In case of spillage, absorb with inert material and dispose of in accordance with applicable regulations.

Environmental

No Information

Cleanup methods

Remove with inert absorbent. Absorb with inert material.

Materials: inert absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

KEEP OUT OF REACH OF CHILDREN! Use in well ventilated area. Provide fresh air such that chemical odors cannot be detected during use and while drying. Avoid prolonged or repeated contact with skin. Avoid contact with eyes. Construction and repair activities can adversely affect indoor air quality. Consult with occupants or a representative (i.e. maintenance, building manager, industrial hygienist, or safety officer) to determine ways to minimize impact.

Storage

Avoid excessive heat and freezing. Keep containers closed when not in use. Store away from caustics and oxidizers.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
Not Established
Evaporation Rate
Slower Than n-Butyl Acetate
Colour Intensity
---
Crystallisation Point
---
Flammability
Non-Flammable
Odor
Slight
Explosive Limits
---
Partition Coefficient
Not Established
Voc Content
---
Metal Corrosion
---
State Under Standard Conditions
---
Appearance
Opaque
Physical State
Liquid
Vapor Density
Heavier Than Air
Bulk Density
---
Dynamic Viscosity
Not Established
Flash Point
100 °C (Seta Closed Cup)
Colour
---
Molecular Weight
---
Solubility In Fat
---
Melting Point
---
Relative Evaporation Rate
---
Form
---
Kinematic Viscosity
---
Physical State Data
liquid
Freezing Point
Not Established
Upper Explosive Limit
N.E.
Solubility
---
Lower Explosive Limit
N.E.
Solidification Point
---
Ph
Between 7.0 and 12.0
Boiling Point
100 - 100 °C
Properties Status
---
Relative Density
---
Density
1.10 - 1.10 g/cm3
Solubility In Water
Not Established
Auto Ignition Temperature
Not Established
Vapor Pressure
Not Established
Cloud Point
---
Softening Point
---
Decomposition Temperature
Not Established
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Avoid

Excessive heat and freezing.

Incompatible

Strong oxidizing agents. Strong bases.

Decomposition

Normal decomposition products, i.e., COx, NOx.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Concrete Bonding Additive?

The signal word is no signal word.

What is the physical form of Concrete Bonding Additive?

Concrete Bonding Additive is a liquid appearing as opaque . It has slight odor.

What is Concrete Bonding Additive used for?

Concrete Bonding Additive