Elevate EPDM Solvent Free Bonding Adhesive
Product Code
W563587029

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Sealant.
Uses Advised Against
None known.

Overview

Elevate EPDM Solvent Free Bonding Adhesive commonly used sealant..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Eye Dam. Category 1
Skin Sens. Category 1
Repr. Category 1B
Aquatic Acute Category 3
Aquatic Chronic Category 3

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.
  • H318: Causes serious eye damage.
  • May damage fertility or the unborn child.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • Obtain special instructions before use.
  • Do not handle until all safety precautions have been read and understood.
  • Avoid breathing mist/vapors.
  • Contaminated work clothing must not be allowed out of the workplace.
  • Avoid release to the environment.
  • Wear protective gloves/protective clothing/eye protection/face protection.
  • If on skin: Wash with plenty of water.
  • If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • Immediately call a poison center/doctor.
  • If skin irritation or rash occurs: Get medical advice/attention.
  • If exposed or concerned: Get medical advice/attention.
  • Wash contaminated clothing before reuse.
  • Store locked up.
  • Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Holcim Solutions and Products US, LLC company logo - Safety Data Sheet supplier organization

Holcim Solutions and Products US, LLC

distributor

๐Ÿ“

26 Century Boulevard, Suite 205 Nashville, TN 37214

๐ŸŒ

US

๐Ÿ“ž

1-800-428-4442

๐ŸŒ holcimelevate.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

1-800-424-9300

๐ŸŒ

US

๐Ÿ’ก

within USA and Canada

CHEMTREC

๐Ÿ“ž

+1 703-527-3887

๐Ÿ’ก

outside USA and Canada (collect calls accepted)

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Aminopropyltrimethoxysilane 13822-56-5 1-5% โœ“ Non-hazardous
Dibutyltin bis(acetylacetonate) 22673-19-4 1% โœ“ Non-hazardous

Composition Notes

All concentrations are in percent by weight unless otherwise indicated. Components not listed are either non-hazardous or are below reportable limits. Any concentration shown as a range is to protect confidentiality or is due to batch variation.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air. Call a physician if symptoms develop or persist.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing immediately and wash skin with soap and water. In case of eczema or other skin disorders: Seek medical attention and take along these instructions.

Symptoms:

May cause an allergic skin reaction. Dermatitis. Rash. Prolonged exposure may cause chronic effects.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately.

Symptoms:

Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision. Permanent eye damage including blindness could result.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Get medical attention if symptoms occur.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention immediately. IF exposed or concerned: Get medical advice/attention.

Medical Treatment

Provide general supportive measures and treat symptomatically. Keep victim under observation.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid.
๐Ÿ‘ƒ Odor
Mild.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
Not determined.
Critical Property
๐Ÿ’จ Boiling Point
> 392 ยฐF (> 200 โ„ƒ)
Critical Property
๐Ÿ”ฅ Flash Point
Does not flash.
Critical Property
๐Ÿ“Š Freezing Point
Not determined.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
Not determined.
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not determined.
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not self-igniting.
๐Ÿ“Š Decomposition Temperature
Not applicable as the product is not unstable.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not applicable, product is a mixture.
๐Ÿ“Š Solubility In Water
Not determined.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
10000 cps (70 ยฐF (21.11 โ„ƒ))
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station.

๐Ÿงค Hand Protection

Wear appropriate chemical resistant gloves. Examples of preferred glove barrier materials include: Nitrile. Suitable gloves can be recommended by the glove supplier.

๐Ÿ‘๏ธ Eye Protection

Wear safety glasses with side shields (or goggles).

๐Ÿ˜ท Respiratory Protection

If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn. Chemical respirator with organic vapor cartridge and full facepiece. Appropriate respirator selection should be made by a qualified professional.

๐Ÿฆบ Skin/Body Protection

Wear appropriate chemical resistant clothing. Use of an impervious apron is recommended.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Elevate EPDM Solvent Free Bonding Adhesive?

The signal word for this substance is "danger".

What is the physical form of Elevate EPDM Solvent Free Bonding Adhesive?

Elevate EPDM Solvent Free Bonding Adhesive is a liquid. with not available. color. It has mild. odor.

What is Elevate EPDM Solvent Free Bonding Adhesive used for?

Sealant.

What are the hazard statements for Elevate EPDM Solvent Free Bonding Adhesive?

This substance has 4 hazard statements: H317: May cause an allergic skin reaction. H318: Causes serious eye damage. May damage fertility or the unborn child. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Elevate EPDM Solvent Free Bonding Adhesive?

The melting point is Not determined. and the boiling point is > 392 ยฐF (> 200 โ„ƒ).