NextSDS Logo
St

Strongcoat Epoxy Base

WARNING Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Strongcoat Epoxy Base
Product Code
C03/06/03/046 - B

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Base part of two component solvent free, nontoxic epoxy protective coating for concrete and metal.

Overview

Strongcoat Epoxy Base commonly used base part of two component solvent free, nontoxic epoxy protective coating for concrete and metal..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1 H317
Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • EUH211: Warning! Hazardous respirable droplets may be formed when sprayed. Do not breathe spray or mist.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H411: Toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
  • P264: Wash hands thoroughly after handling.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P501: Dispose of contents/container to an authorised waste collection point

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

DCP Saudi Co

manufacturer

๐Ÿ“

P.O. Box 66241, Riyadh 11576, Kingdom of Saudi Arabia

๐ŸŒ

SA

๐Ÿ“ž

+ 966 11 4612003

๐Ÿ“ 

+ 966 11 2792059

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+ 966 11 4612003

๐ŸŒ

SA

๐Ÿ•’

available during office hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Reaction product: bisphenol-A-(epichlorhydrin); epoxy resin (number average molecular weight โ‰ค 700)

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
bisphenol-A-(epichlorhydrin); epoxy resin
EC: 500-033-5
25068-38-6 20-30% โš ๏ธ Hazardous
oxirane, mono[(C12-14-alkyloxy)methyl] derivs.
EC: 271-846-8
68609-97-2 1-10% โš ๏ธ Hazardous
Polyamine amide salt N/A 0.5% โš ๏ธ Hazardous
ethylbenzene
EC: 202-849-4
100-41-4 0.05% โš ๏ธ Hazardous
2-methylpropan-1-ol; iso-butanol
EC: 201-148-0
78-83-1 0.05% โš ๏ธ Hazardous
XYLENE
EC: 215-535-7
1330-20-7 0.5% โš ๏ธ Hazardous
Distillates (petroleum), hydrotreated light; Kerosine - unspecified
EC: 265-149-8
64742-47-8 0.1% โš ๏ธ Hazardous
Phenol, methylstyrenated
EC: 270-966-8
68512-30-1 0.05% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing. Seek medical attention if ill effects occur.

Symptoms:

No specific symptoms known.

๐Ÿ–๏ธ Skin Contact

Wash skin thoroughly with soap and water. Remove contaminated clothing. Get medical attention if irritation persists. Wash contaminated clothing before reuse.

Symptoms:

Irritating to skin. Causes allergic reaction in susceptible people.

๐Ÿ‘๏ธ Eye Contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.

Symptoms:

Irritating to eyes.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do NOT induce vomiting. Get immediate medical advice/attention.

๐Ÿšจ Immediate Medical Attention Required

Get immediate medical advice/attention.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Various
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Characteristic odour
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
No information available
๐ŸงŠ Melting Point
Not available
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
>93ยฐโ„ƒ
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.77 ยฑ 0.05 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
No information available
๐Ÿ“Š Upper Explosive Limit
NA% (in air)
๐Ÿ“Š Lower Explosive Limit
NA% (in air)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Immiscible with water
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
NA mm2/s
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Wear suitable protective gloves

๐Ÿ‘๏ธ Eye Protection

Wear suitable eye/face protection

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3082

๐Ÿ“ฆ Proper Shipping Name

ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID. N.O.S.

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Strongcoat Epoxy Base?

The signal word for this substance is "warning".

What is the physical form of Strongcoat Epoxy Base?

Strongcoat Epoxy Base is a liquid with various color. It has characteristic odour odor.

What is Strongcoat Epoxy Base used for?

Base part of two component solvent free, nontoxic epoxy protective coating for concrete and metal.

What are the hazard statements for Strongcoat Epoxy Base?

This substance has 5 hazard statements: EUH211: Warning! Hazardous respirable droplets may be formed when sprayed. Do not breathe spray or mist. H315: Causes skin irritation. H317: May cause an allergic skin reaction. H319: Causes serious eye irritation. H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Strongcoat Epoxy Base?

The melting point is Not available and the boiling point is No data available.