NextSDS Logo
Safety Data Sheet EN

Suma® Freeze Freezer Cleaner

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Suma® Freeze Freezer Cleaner
Product Code
MS0800366

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Kitchen hygiene product; This product is intended to be used neat.; Industrial/Institutional

Uses advised against

Uses other than those identified are not recommended

Manufacturers & Suppliers

Diversey, Inc. logo

Diversey, Inc.

manufacturer

1300 Altura Rd., Suite 125, Fort Mill, SC 29708

1-888-352-2249

https://sds.diversey.com

D

Diversey Canada, Inc.

manufacturer

6150 Kennedy Road Unit 3, Mississauga, Ontario L5T 2J4

1-800-668-7171

Emergency Contacts

Emergency Contact

1-800-851-7145

Emergency Contact

1-651-917-6133

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

DO NOT MIX WITH AMMONIA, BLEACH OR OTHER CHLORINATED COMPOUNDS.
Mix only with water.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2-(2-butoxyethoxy)ethanol 112-34-5 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No specific first aid measures are required.

Skin contact

No specific first aid measures are required.

Eye contact

Rinse with plenty of water. If irritation occurs and persists, get medical attention.

Ingestion

Rinse mouth with water.

Immediate Medical Attention

Not applicable.

Medical Treatment

Not applicable.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

The product is not flammable. Extinguish fire using agent suitable for surrounding fire.

Unsuitable media

No information available.

Specific hazards

None known.

Instructions

No special methods required

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Large spill

Absorb spill with inert material (e.g. dry sand or earth), then place in a chemical waste container. Use a water rinse for final clean-up.

Environmental

Clean-up methods - large spillage. Absorb spill with inert material (e.g. dry sand or earth), then place in a chemical waste container. Use a water rinse for final clean-up.

Cleanup methods

Absorb spill with inert material (e.g. dry sand or earth), then place in a chemical waste container. Use a water rinse for final clean-up.

Materials: inert material (e.g. dry sand or earth), chemical waste container

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin, eyes and clothing. FOR COMMERCIAL AND INDUSTRIAL USE ONLY.

Storage

Keep tightly closed in a dry, cool and well-ventilated place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control airborne levels.

Hands

No personal protective equipment required under normal use conditions.

Eyes

No personal protective equipment required under normal use conditions.

Respiratory

No personal protective equipment required under normal use conditions.

Skin/Body

No personal protective equipment required under normal use conditions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Properties Status
---
Molecular Weight
---
Solubility In Fat
---
Flammability
Not applicable
Metal Corrosion
Not corrosive to metals
Kinematic Viscosity
---
Solubility In Water
---
Odor Threshold
No information available.
Freezing Point
Not determined
Bulk Density
No information available
Physical State Data
liquid
Lower Explosive Limit
Not determined
Partition Coefficient
No information available
Form
---
Voc Content
0 %
Solubility
Completely Soluble
Boiling Point
Not determined
Decomposition Temperature
Not determined
Appearance
Clear, Light, Blue
Evaporation Rate
No information available
Relative Evaporation Rate
---
Vapor Pressure
No information available.
Melting Point
Not determined
Auto Ignition Temperature
No information available
Dynamic Viscosity
8 cP
Cloud Point
---
Explosive Limits
---
Colour Intensity
Light
Vapor Density
No information available
Ph
11.5
Physical State
Liquid
Colour
Clear, Light, Blue
Density
1.025 Kg/L
Upper Explosive Limit
Not determined
Crystallisation Point
---
Solidification Point
---
Softening Point
---
Odor
Solvent
Flash Point
>200.1 °F >93.4 °C
Relative Density
1.03
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable

Reactivity

Not Applicable

Hazardous reactions

May vigorously react with acids resulting in spattering and excessive heat.

Avoid

None known.

Incompatible

Acids. Strong acids. Do not mix with any other product or chemical unless specified in the use directions.

Decomposition

Decomposition may produce fumes, smoke, oxides of carbon and hydrocarbons.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose in compliance with all Federal, state, provincial, and local laws and regulations.

Waste Codes

Not Regulated RCRA
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Suma® Freeze Freezer Cleaner?

The signal word is no signal word.

What is the physical form of Suma® Freeze Freezer Cleaner?

Suma® Freeze Freezer Cleaner is a liquid appearing as clear, light, blue with clear, light, blue color. It has solvent odor.

What is the solubility of Suma® Freeze Freezer Cleaner?

Completely Soluble

What is Suma® Freeze Freezer Cleaner used for?

Kitchen hygiene product; This product is intended to be used neat.; Industrial/Institutional

What is the melting point of Suma® Freeze Freezer Cleaner?

The melting point is Not determined and the boiling point is Not determined.