NextSDS Logo
Bu

Buffer Solution( Borate ) pH 10 Blue

WARNING SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Buffer Solution( Borate ) pH 10 Blue
Product Code
5655-01

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
For Laboratory, Research or Manufacturing use.

Overview

Buffer Solution( Borate ) pH 10 Blue commonly used for laboratory, research or manufacturing use..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Irr. Category 2 H315
Eye Irrit. Category 2 H319

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

Precautionary Statements

  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P264: Wash thoroughly after handling.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P362: Take off contaminated clothing and wash before reuse.
  • P332+P313: If skin irritation occurs: Get medical advice/attention.
  • P337+P313: If eye irritation persists: Get medical advice/attention.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Avantor Performance Materials B.V.

manufacturer

๐Ÿ“

P.O.Box 1 7400 AA Deventer The Netherlands

๐ŸŒ

NL

๐Ÿ“ 

(+31) (0)570 - 687574

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Environment Health & Safety department

๐Ÿ“ž

(+31)(0) 570 687500

๐ŸŒ

NL

๐Ÿ•’

during normal opening times (8 am till 5.30 pm)

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

Mixture of the substances listed below with harmless additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Boric Acid
EC: 233-139-2
10043-35-3 Not specified โš ๏ธ Hazardous
Potassium Hydroxide
EC: 215-181-3
1310-58-3 Not specified โš ๏ธ Hazardous

Additional Information

For the wording of the listed risk phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

In case of unconsciousness bring patient into stable side position for transport.

๐Ÿ–๏ธ Skin Contact

Instantly wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

In case of persistent symptoms consult doctor.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
According to product specification
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Fluid
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
0C
Critical Property
๐Ÿ’จ Boiling Point
100C
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
23 hPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Product is not selfigniting.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Fully miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0.00 %
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed safety glasses.

๐Ÿ˜ท Respiratory Protection

In case of brief exposure or low pollution use breathing filter apparatus. In case of intensive or longer exposure use breathing apparatus that is independent of circulating air.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3266

๐Ÿ“ฆ Proper Shipping Name

CORROSIVE LIQUID, BASIC, INORGANIC, N.O.S., mixture

โš ๏ธ Transport Hazard Class

8

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

Warning: Corrosive substances.

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Corrosive substances.

โœˆ๏ธ IATA Air Transport Precautions

Warning: Corrosive substances.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Buffer Solution( Borate ) pH 10 Blue?

The signal word for this substance is "warning".

What is Buffer Solution( Borate ) pH 10 Blue used for?

For Laboratory, Research or Manufacturing use.

What are the hazard statements for Buffer Solution( Borate ) pH 10 Blue?

This substance has 2 hazard statements: H315: Causes skin irritation. H319: Causes serious eye irritation.

What is the melting point of Buffer Solution( Borate ) pH 10 Blue?

The melting point is 0C and the boiling point is 100C.