NextSDS Logo
Safety Data Sheet EN

Buffer Solution (Borate) pH 10 Blue

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Buffer Solution (Borate) pH 10 Blue
Product Code
5655-01

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For Laboratory, Research or Manufacturing use.

Manufacturers & Suppliers

A

Avantor Performance Materials B.V.

manufacturer

P.O.Box 1, 7400 AA Deventer, The Netherlands

(+31) (0)570 - 687500

Emergency Contacts

Environment Health & Safety department

(+31)(0) 570 687500

during normal opening times (8 am till 5.30 pm)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash thoroughly after handling.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P332+P313 If skin irritation occurs: Get medical advice/attention.
P337+P313 If eye irritation persists: Get medical advice/attention.
P362 Take off contaminated clothing and wash before reuse.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixtures

Mixture of the substances listed below with harmless additions.

Chemical Name CAS Number Concentration Hazardous
Boric Acid EC: 233-139-2 10043-35-3 --- Yes
Potassium Hydroxide EC: 215-181-3 1310-58-3 --- Yes

For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness bring patient into stable side position for transport.

Skin contact

Instantly wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.

Ingestion

In case of persistent symptoms consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed safety glasses.

Respiratory

In case of brief exposure or low pollution use breathing filter apparatus. In case of intensive or longer exposure use breathing apparatus that is independent of circulating air.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Flammability
Product is not selfigniting.
Decomposition Temperature
Not determined.
Ph
Not determined.
Colour
According to product specification
Solubility In Water
Fully miscible
Upper Explosive Limit
Not determined.
Flash Point
Not applicable
Evaporation Rate
Not determined.
Dynamic Viscosity
Not determined.
Crystallisation Point
---
Relative Density
Not determined.
Kinematic Viscosity
Not determined.
Appearance
---
Vapor Pressure
23 hPa
Cloud Point
---
Voc Content
0.00 %
Softening Point
---
Odor Threshold
Not determined.
Properties Status
---
Auto Ignition Temperature
---
Freezing Point
---
Molecular Weight
---
Explosive Limits
---
Colour Intensity
---
Solubility
---
Form
Fluid
Physical State
Fluid
Odor
Characteristic
Lower Explosive Limit
Not determined.
Relative Evaporation Rate
---
Bulk Density
---
Metal Corrosion
---
Boiling Point
100C
Melting Point
0C
Vapor Density
Not determined.
Physical State Data
---
Density
---
Partition Coefficient
Not determined.
Solubility In Fat
---
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3266
Shipping Name
CORROSIVE LIQUID, BASIC, INORGANIC, N.O.S., mixture
Transport Class
8
Packing Group
III
ADR

Warning: Corrosive substances.

IMDG

Warning: Corrosive substances.

IATA

Warning: Corrosive substances.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Buffer Solution (Borate) pH 10 Blue?

The signal word is warning.

What is the physical form of Buffer Solution (Borate) pH 10 Blue?

Buffer Solution (Borate) pH 10 Blue is a fluid with according to product specification color. It has characteristic odor.

What is Buffer Solution (Borate) pH 10 Blue used for?

For Laboratory, Research or Manufacturing use.

What are the hazard statements for Buffer Solution (Borate) pH 10 Blue?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

What is the melting point of Buffer Solution (Borate) pH 10 Blue?

The melting point is 0C and the boiling point is 100C.