01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Electrode Cleaning Solution for General Use
Product Code
HI7061
Chemical Name
HYDROCHLORIC ACID 0.034%
Synonyms
HYDROCHLORIC ACID 0.034%

Regulatory Identifiers

CAS Number
7647-01-0 Check regulations →
EC Number
231-595-7 Check regulations →
REACH No.
01-2119484862-26

Identified Uses

Cleaning Solution for Electrodes.

Manufacturers & Suppliers

H

Hanna Instruments S.R.L.

manufacturer

str. Hanna Nr 1, 457260 loc. Nusfalau (Salaj), Romania

+40 260607700

H

Hanna Instruments, Inc

distributor

584 Park East Drive, Woonsocket, Rhode Island, USA 02895

+1 8004266287

Emergency Contacts

CHEMTREC

+1 8004249300

24 hours/365 days

CHEMTREC

+1 7035273887

24 hours/365 days

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

The product does not contain substances classified as being hazardous to human health or the environment pursuant to the provisions set forth in OSHA Hazard Communication Standard (HCS) (29 CFR 1910.1200).

04

First Aid Measures

Emergency procedures for chemical exposure incidents

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

carbon dioxide, foam, powder and water spray.

Unsuitable media

None in particular.

Specific hazards

Do not breathe combustion products.

Instructions

Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health.

Firefighter Protection

Always wear full fire prevention gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use breathing equipment if fumes or powders are released into the air. These indications apply for both processing staff and those involved in emergency procedures.

Environmental

The product must not penetrate into the sewer system or come into contact with surface water or ground water.

Cleanup methods

Collect as much material as possible and eliminate the rest using jets of water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Before handling the product, consult all the other sections of this material safety data sheet. Do not eat, drink or smoke during use.

Storage

Keep the product in clearly labelled containers.

Hygiene

Do not eat, drink or smoke during use.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

None required.

Eyes

None required.

Respiratory

If the threshold value (e.g. TLV-TWA) is exceeded for the substance or one of the substances present in the product, wear a mask with a NIOSH certified filter, whose class must be chosen according to the limit of use concentration (NIOSH 42 CFR 84, OSHA 29 CFR 1910.134). In the presence of gases or vapours of various kinds and/or gases or vapours containing particulate (aerosol sprays, fumes, mists, etc.) combined filters are required. Respiratory protection devices must be used if the technical measures adopted are not suitable for restricting the worker's exposure to the threshold values considered. The protection provided by masks is in any case limited. If the substance considered is odourless or its olfactory threshold is higher than the corresponding TLV-TWA and in the case of an emergency, wear open-circuit compressed air breathing apparatus or external air-intake breathing apparatus. For a correct choice of respiratory protection device, see standard NIOSH 42 CFR 84, OSHA 29 CFR 1910.134.

Skin/Body

None required.

Environmental

The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with environmental standards.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Evaporation Rate
not available
Physical State Data
liquid
Voc Content
---
Bulk Density
---
Odor
odourless
Upper Explosive Limit
not available
Decomposition Temperature
not available
Colour Intensity
---
Lower Explosive Limit
not available
Molecular Weight
---
Physical State
liquid
Relative Density
1
Flash Point
not applicable
Partition Coefficient
not available
Cloud Point
---
Ph
2.1
Properties Status
---
State Under Standard Conditions
---
Density
---
Boiling Point
not available
Solubility In Water
soluble in water
Crystallisation Point
---
Kinematic Viscosity
---
Relative Evaporation Rate
---
Colour
colourless
Melting Point
not available
Metal Corrosion
---
Auto Ignition Temperature
not available
Odor Threshold
not available
Freezing Point
not available
Solubility
soluble in water
Vapor Density
not available
Solidification Point
---
Flammability
not available
Solubility In Fat
---
Dynamic Viscosity
---
Appearance
liquid
Explosive Limits
---
Softening Point
---
Vapor Pressure
17.5 mmHg
Form
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable in normal conditions of use and storage.

Reactivity

There are no particular risks of reaction with other substances in normal conditions of use.

Hazardous reactions

No hazardous reactions are foreseeable in normal conditions of use and storage.

Avoid

None in particular. However the usual precautions used for chemical products should be respected.

Incompatible

Information not available

Decomposition

Information not available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal must be performed through an authorised waste management firm, in compliance with national and local regulations.

Disposal

Reuse, when possible.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
not applicable
Shipping Name
not applicable
Transport Class
not applicable
Packing Group
not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Electrode Cleaning Solution for General Use known by?

Electrode Cleaning Solution for General Use is also known as: HYDROCHLORIC ACID 0.034%

What is the hazard signal word for Electrode Cleaning Solution for General Use?

The signal word is no signal word.

What is the physical form of Electrode Cleaning Solution for General Use?

Electrode Cleaning Solution for General Use is a liquid appearing as liquid with colourless color. It has odourless odor.

What is the solubility of Electrode Cleaning Solution for General Use?

soluble in water

What is Electrode Cleaning Solution for General Use used for?

Cleaning Solution for Electrodes.

What is the melting point of Electrode Cleaning Solution for General Use?

The melting point is not available and the boiling point is not available.