NextSDS Logo
OL

OLYMPUS CLEANER

NO SIGNAL WORD Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
OLYMPUS CLEANER
Product Code
107501E

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Instrument cleaner, Medical devices, Semi-automatic process
Uses Advised Against
None known.

Overview

OLYMPUS CLEANER commonly used instrument cleaner, medical devices, semi-automatic process.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Ecolab Deutschland GmbH

manufacturer

๐Ÿ“

Reisholzer Werftstrasse 38-42 Postfach 13 04 06 DE-40554 Dsseldorf

๐ŸŒ

DE

๐Ÿ“ž

+49 (0)211 9893 0

๐Ÿ“ 

+49 (0)211 9893 384

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Giftinformationszentrum-Nord (GIZ-Nord) Gttingen)

๐Ÿ“ž

0551 19240

๐ŸŒ

DE

Giftinformationszentrum-Nord (GIZ-Nord) Gttingen)

๐Ÿ“ž

0551/3831881

๐ŸŒ

DE

๐Ÿ•’

24/7

Ecolab Deutschland GmbH

๐Ÿ“ž

+49 (0) 211 98 93 700

๐ŸŒ

DE

๐Ÿ•’

24/7

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Fatty alcohol ethoxylate 147993-63-3 5-10% โš ๏ธ Hazardous
Sodiumcumenesulphonate
EC: 248-983-7
28348-53-0 1-5% โš ๏ธ Hazardous

Additional Information

Occupational exposure limits, if available, are listed in Section 8.

Composition Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms:

No known significant effects or critical hazards.

๐Ÿ–๏ธ Skin Contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms:

No known significant effects or critical hazards.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms:

No known significant effects or critical hazards.

๐Ÿฝ๏ธ Ingestion/Swallowing

Wash out mouth with water. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms:

No known significant effects or critical hazards.

๐Ÿšจ Immediate Medical Attention Required

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled. No specific treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Faint odour
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
5.5 [Conc. (% w/w): 100%]
๐ŸงŠ Melting Point
Not applicable and/or not determined for the mixture.
Critical Property
๐Ÿ’จ Boiling Point
Not applicable and/or not determined for the mixture.
Critical Property
๐Ÿ”ฅ Flash Point
- 100C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable and/or not determined for the mixture.
๐Ÿ’จ Vapor Pressure
Not applicable and/or not determined for the mixture.
๐Ÿ“Š Vapor Density
Not applicable and/or not determined for the mixture.
๐Ÿ“Š Relative Density
1.06
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not applicable and/or not determined for the mixture.
๐Ÿ“Š Upper Explosive Limit
Not applicable and/or not determined for the mixture.
๐Ÿ“Š Lower Explosive Limit
Not applicable and/or not determined for the mixture.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not applicable and/or not determined for the mixture.
๐Ÿ“Š Decomposition Temperature
Not applicable and/or not determined for the mixture.
๐Ÿ’ง Solubility
Easily soluble in the following materials: cold water.
๐Ÿ“Š Partition Coefficient
Not applicable and/or not determined for the mixture.
๐Ÿ“Š Solubility In Water
Easily soluble in cold water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants. If this product contains ingredients with exposure limits, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure below any recommended or statutory limits.

๐Ÿงค Hand Protection

No special recommendations. (EN 374)

๐Ÿ‘๏ธ Eye Protection

No special recommendations. (EN 166)

๐Ÿ˜ท Respiratory Protection

A respirator is not needed under normal and intended conditions of product use. (EN 143, 14387)

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. (EN 14605)

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for OLYMPUS CLEANER?

The signal word for this substance is "no signal word".

What is the physical form of OLYMPUS CLEANER?

OLYMPUS CLEANER is a liquid. with colourless. color. It has faint odour odor.

What is the solubility of OLYMPUS CLEANER?

Easily soluble in the following materials: cold water.

What is OLYMPUS CLEANER used for?

Instrument cleaner, Medical devices, Semi-automatic process

What is the melting point of OLYMPUS CLEANER?

The melting point is Not applicable and/or not determined for the mixture. and the boiling point is Not applicable and/or not determined for the mixture..