Product Information

Product Name
OLYMPUS CLEANER
Product Code
107501E

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Instrument cleaner, Medical devices, Semi-automatic process

Uses advised against

None known.

Manufacturers & Suppliers

E

Ecolab Deutschland GmbH

manufacturer

Reisholzer Werftstrasse 38-42 Postfach 13 04 06 DE-40554 Dsseldorf

+49 (0)211 9893 0

Emergency Contacts

Giftinformationszentrum-Nord (GIZ-Nord) Gttingen)

0551 19240

Giftinformationszentrum-Nord (GIZ-Nord) Gttingen)

0551/3831881

24/7

Ecolab Deutschland GmbH

+49 (0) 211 98 93 700

24/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixtures
Chemical Name CAS Number Concentration Hazardous
Fatty alcohol ethoxylate 147993-63-3 5 - 10% Yes
Sodiumcumenesulphonate EC: 248-983-7 28348-53-0 1 - 5% Yes

Occupational exposure limits, if available, are listed in Section 8.

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled. No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water spray (fog), foam, dry chemical or CO 2 .

Unsuitable media

None known.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear proper protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Put on appropriate personal protective equipment.

Small spill

Dilute with plenty of water. Absorb with an inert material and place in an appropriate waste disposal container.

Large spill

Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see section 13).

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with plenty of water. Absorb with an inert material. Contain and collect spillage with non-combustible, absorbent material.

Materials: inert material; non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store between the following temperatures: 0 to 25C (32 to 77F). Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled containers. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants. If this product contains ingredients with exposure limits, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure below any recommended or statutory limits.

Hands

No special recommendations. (EN 374)

Eyes

No special recommendations. (EN 166)

Respiratory

A respirator is not needed under normal and intended conditions of product use. (EN 143, 14387)

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. (EN 14605)

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour Intensity
---
Lower Explosive Limit
Not applicable and/or not determined for the mixture.
Molecular Weight
---
Solubility
Easily soluble in the following materials: cold water.
Relative Evaporation Rate
---
Form
---
Decomposition Temperature
Not applicable and/or not determined for the mixture.
Melting Point
Not applicable and/or not determined for the mixture.
Cloud Point
---
Colour
Colourless.
Dynamic Viscosity
---
Bulk Density
---
Relative Density
1.06
Evaporation Rate
Not applicable and/or not determined for the mixture.
Solubility In Fat
---
Ph
5.5 [Conc. (% w/w): 100%]
Freezing Point
---
Metal Corrosion
---
Flammability
Not applicable and/or not determined for the mixture.
Density
---
State Under Standard Conditions
---
Partition Coefficient
Not applicable and/or not determined for the mixture.
Flash Point
- 100C
Upper Explosive Limit
Not applicable and/or not determined for the mixture.
Physical State Data
liquid
Vapor Density
Not applicable and/or not determined for the mixture.
Odor
Faint odour
Explosive Limits
---
Physical State
Liquid.
Solubility In Water
Easily soluble in cold water.
Voc Content
---
Kinematic Viscosity
---
Appearance
---
Vapor Pressure
Not applicable and/or not determined for the mixture.
Properties Status
---
Odor Threshold
---
Crystallisation Point
---
Boiling Point
Not applicable and/or not determined for the mixture.
Solidification Point
---
Softening Point
---
Auto Ignition Temperature
Not applicable and/or not determined for the mixture.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No specific data.

Incompatible

No specific data.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Significant quantities of waste product residues should not be disposed of via the foul sewer but processed in a suitable effluent treatment plant. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Disposal

The generation of waste should be avoided or minimised wherever possible. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe way. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Disposal of this product, solutions and any byproducts should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Waste Codes

20 01 30 detergents other than those mentioned in 20 01 29 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for OLYMPUS CLEANER?

The signal word is no signal word.

What is the physical form of OLYMPUS CLEANER?

OLYMPUS CLEANER is a liquid. with colourless. color. It has faint odour odor.

What is the solubility of OLYMPUS CLEANER?

Easily soluble in the following materials: cold water.

What is OLYMPUS CLEANER used for?

Instrument cleaner, Medical devices, Semi-automatic process

What is the melting point of OLYMPUS CLEANER?

The melting point is Not applicable and/or not determined for the mixture. and the boiling point is Not applicable and/or not determined for the mixture..

Compliance Scanner

Scan your compliance