Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Sodium standard solution 1000 µg/ml (Plasma HIQU)
- Product Code
- CL01.1401
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
CHEM-LAB NV
manufacturer
Industriezone "De Arend" 2, B-8210 Zedelgem, BELGIUM
+32 50 28 83 20
Emergency Contacts
CHEM-LAB NV
00 (32) 50.28.83.20
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Nitric acid 67 - 69% (Pico-Pure) | 7697-37-2 | 2 - 5% | Yes |
Notes
For the full text of H-Phrases mentioned in this Section, see Section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air.
Wash off with plenty of water. Remove contaminated clothing.
Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open. lmmediately call an ophtalmologist.
Never give anything by mouth to an unconscious person. Immediately make victim drink water (two glasses at most). Call in physician.
Immediate Medical Attention
lmmediately call an ophtalmologist. Call in physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Potassium standard solution 1000 µg/ml (Plasma HIQU)
---
Calcium standard solution 1000 µg/ml (Plasma HIQU)
---
Nickel standard solution 1000 µg/ml (Plasma HIQU)
---
Iron standard solution 1000 µg/ml (Plasma HIQU)
---
Copper standard solution 1000 µg/ml (Plasma HIQU)
---
Zinc standard solution 1000 µg/ml (Plasma HIQU)
---
Selenium standard solution 1000 µg/ml (Plasma HIQU)
---
Magnesium standard solution 1000 µg/ml (Plasma HIQU)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective clothing should be selected specificlly for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier.
Required.
Required.
Required when vapours/aerosols are generated. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Required.
Do not allow to enter sewerage system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 3264
- Shipping Name
- Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)
- Transport Class
- 8
- Packing Group
- III
no
no
no
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Sodium standard solution 1000 µg/ml (Plasma HIQU)?
The signal word is warning.
What is the physical form of Sodium standard solution 1000 µg/ml (Plasma HIQU)?
Sodium standard solution 1000 µg/ml (Plasma HIQU) is a liquid with colourless color. It has odourless odor.
What is Sodium standard solution 1000 µg/ml (Plasma HIQU) used for?
Reagent for analysis
What are the hazard statements for Sodium standard solution 1000 µg/ml (Plasma HIQU)?
This substance has 1 hazard statement:
- H315: Causes skin irritation.
What is the melting point of Sodium standard solution 1000 µg/ml (Plasma HIQU)?