NextSDS Logo
il

illbruck SP050

NO SIGNAL WORD Fluid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
illbruck SP050
Product Code
T-I-SP050

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
PC1 Adhesives, sealants; Adhesives; Spacings sealant

Overview

illbruck SP050 commonly used pc1 adhesives, sealants; adhesives; spacings sealant.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Void)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Tremco CPG Germany GmbH

manufacturer

๐Ÿ“

Zweigniederlassung Traunreut Traunring 65, D - 83301 Traunreut

๐ŸŒ

DE

๐Ÿ“ž

+49 (0) 8669 34100

๐Ÿ“ 

+49 (0) 8669 9784

Tremco CPG UK Ltd company logo - Safety Data Sheet supplier organization

Tremco CPG UK Ltd

national supplier

๐Ÿ“

Coupland Road, Hindley Green, Wigan, WN2 4HT

๐ŸŒ

GB

๐Ÿ“ 

+44 (0) 1942251410

๐ŸŒ www.cpg-europe.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

NHS

๐Ÿ“ž

111

๐ŸŒ

GB

๐Ÿ’ก

England/Wales/Scotland

Emergency Contact

๐Ÿ“ž

01 809 2166

๐ŸŒ

IE

๐Ÿ’ก

ROI

Emergency Contact

๐Ÿ“ž

+44 (0) 1942251400

๐ŸŒ

GB

๐Ÿ•’

During office hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

Silane-terminated, hydrocarbon-based polymer with inorganic fillers

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
di-''isononyl'' phthalate
EC: 249-079-5
28553-12-0 10-20% โš ๏ธ Hazardous
N-(3-(trimethoxysilyl)propyl)ethylenediamine
EC: 217-164-6
1760-24-3 0.1-1% โš ๏ธ Hazardous
trimethoxyvinylsilane
EC: 220-449-8
2768-02-7 0.1-1% โš ๏ธ Hazardous

Additional Information

EU SVHC see Section 15; GB SVHC see Section 15

Composition Notes

For the wording of the listed hazard phrases refer to section 16. While curing the following substances are formed and released by a reaction with atmospheric humidity: Methanol (CAS 67-56-1)

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Remove from the skin using a cloth or paper. Then clean with water and soap. If skin irritation continues, consult a doctor.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse out mouth and then drink plenty of water. Do not induce vomiting; call for medical help immediately.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
According to product specification
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Pasty
๐Ÿ‘ƒ Odor
Alcohol-like
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Mixture is non-polar/aprotic.
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
>151 C
Critical Property
๐Ÿ“Š Freezing Point
Undetermined.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
2.6 hPa (CAS: 28553-12-0 di-'isononyl' phthalate)
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.68 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
0.2 Vol %
๐Ÿ“Š Lower Explosive Limit
<0.1 Vol % (CAS: 28553-12-0 di-'isononyl' phthalate)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Product is not selfigniting.
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Fully miscible.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0.01 %
๐Ÿ“Š Metal Corrosion
Void
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Butyl rubber, BR, Nitrile rubber, NBR. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

Not necessary if room is well-ventilated. Filter AX. Use suitable respiratory protective device in case of insufficient ventilation. For further guidance, please refer to HSE HSG53 "Respiratory Protective Equipment at work - A Practical Guide".

๐Ÿฆบ Skin/Body Protection

Protective work clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for illbruck SP050?

The signal word for this substance is "no signal word".

What is the physical form of illbruck SP050?

illbruck SP050 is a fluid with according to product specification color. It has alcohol-like odor.

What is illbruck SP050 used for?

PC1 Adhesives, sealants; Adhesives; Spacings sealant

What is the melting point of illbruck SP050?

The melting point is Undetermined. .