Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation
- Product Code
- NOAL_0061A
- Chemical Name
- Helium
- Synonyms
- Helium
Regulatory Identifiers
- CAS Number
- 7440-59-7 Check regulations →
- EC Number
- 231-168-5 Check regulations →
- REACH No.
- Listed in Annex IV / V REACH, exempted from registration.
Identified Uses
Industrial and professional uses. Perform risk assessment prior to use. Test gas/Calibration gas. Laboratory use. Purge gas, diluting gas, inerting gas. Purging. Use for manufacture of electronic/photovoltaic components. Shield gas for welding processes. Contact supplier for more information on uses.
Uses advised against
Do not inhale product on purpose because of the risk of asphyxiation. Uses other than those listed above are not supported, contact your supplier for more information on other uses.
Manufacturers & Suppliers
AIR LIQUIDE NORWAY AS
Drammensveien 64 B, 3050 Mjøndalen - NORWAY
+ 47 32 27 41 40
Emergency Contacts
Emergency Contact
112
Giftinformasjon
+47 22 59 13 00
24 / 7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Contains no other components or impurities which will influence the classification of the product.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Helium EC: 231-168-5 | 7440-59-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to uncontaminated area. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.
Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.
Immediate Medical Attention
None.
Medical Treatment
Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Helium
---
Helium
CAS: 7440-59-7
Nitrogen (0.0001 - 10%), Helium (Balance)
---
Carbon Monoxide (0.1000% - 0.9999%), Helium (0.0001% - 80.3999%), Oxygen (19.50% 23.50%) in Nitrogen
---
Calibration gas, Test gas, Kalibriergas H2S, CO, CO2, CH4, C3H8, C5H12, EtOH, N2-Bal [configured]
---
Calibration gas, Test gas, H2S, NO2, CO, CO2, NH3, H2, SO2, CH4, C2H4, C3H8, C4H10, C4H8, C5H12, C6H14, C7H8, SF6, O2, N2-Bal [configured]
---
Compressed Gas, containing <= 21 Vol.-% Oxygen, Carbon dioxide, balance Nitrogen
---
Argon, compressed
CAS: 7440-37-1
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate general and local exhaust ventilation. Systems under pressure should be regularily checked for leakages. Oxygen detectors should be used when asphyxiating gases may be released. Consider the use of a work permit system e.g. for maintenance activities.
Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risk, performance level 1 or higher.
Wear safety glasses with side shields. Standard EN 166 - Personal eye-protection - specifications.
Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres. Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems.
Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
None necessary.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1046
- Shipping Name
- HELIUM, COMPRESSED
- Transport Class
- 2.2
- Packing Group
- Not established.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation known by?
Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation is also known as: Helium
What is the hazard signal word for Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation?
The signal word is warning.
What is the physical form of Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation?
Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation is a gas with colourless. color. It has no odour warning properties. odor.
What is Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation used for?
Industrial and professional uses. Perform risk assessment prior to use. Test gas/Calibration gas. Laboratory use. Purge gas, diluting gas, inerting gas. Purging. Use for manufacture of electronic/photovoltaic components. Shield gas for welding processes. Contact supplier for more information on uses.
What are the hazard statements for Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation?
The melting point is -272 C and the boiling point is -269 C.