Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Helium
- Product Code
- SDS-061A-CLP
- Chemical Name
- Helium
Regulatory Identifiers
- CAS Number
- 7440-59-7 Check regulations →
- EC Number
- 231-168-5 Check regulations →
- REACH No.
- Listed in Annex IV / V REACH, exempted from registration.
Identified Uses
Industrial and professional. Perform risk assessment prior to use. Test gas/Calibration gas. Purge gas, diluting gas, inerting gas. Purging. Laboratory use. Use for manufacture of electronic/photovoltaic components. Shield gas for welding processes. Contact supplier for more information on uses.
Manufacturers & Suppliers
Air Liquide UK Ltd.
manufacturer
Station Road, Coleshill, B46 1JY Birmingham, United Kingdom
01675462424
Emergency Contacts
Emergency Contact
01675 462695
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Helium EC: 231-168-5 | 7440-59-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Apply artificial respiration if breathing stopped.
Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.
Adverse effects not expected from this product.
Adverse effects not expected from this product.
Ingestion is not considered a potential route of exposure.
Immediate Medical Attention
None.
Medical Treatment
None.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray or fog.
Do not use water jet to extinguish.
Exposure to fire may cause containers to rupture/explode.
Use fire control measures appropriate for the surrounding fire. Cool endangered receptacles with water spray jet from a protected position. Prevent water used in emergency cases from entering sewers and drainage systems. If possible, stop flow of product. Use water spray or fog to knock down fire fumes if possible. Move containers away from the fire area if this can be done without risk.
Firefighter Protection
Use self-contained breathing apparatus. Standard protective clothing and equipment (Self Contained Breathing Apparatus) for fire fighters. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Standard EN 469 - Protective clothing for firefighters. Standard - EN 659: Protective gloves for firefighters.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Try to stop release. Evacuate area. Wear self-contained breathing apparatus when entering area unless atmosphere is proved to be safe. Ensure adequate air ventilation. Act in accordance with local emergency plan. Stay upwind.
Try to stop release.
Ventilate area
Related Products
Similar products with comparable safety profiles
Helium
---
Helium
CAS: 7440-59-7
Helium, Medical helium, Helium N25, Helium N45, Helium N50, Helium N55, Lasal 4, Lasal 2004, Alphagaz 1 Helium, Alphagaz 2 Helium, Helium HG, Helium Ballon, Albee Fly He, Helium flotation
CAS: 7440-59-7
Nitrogen (0.0001 - 10%), Helium (Balance)
---
Helium, glass flask
---
Hydrogen
CAS: 1333-74-0
Argon
---
Argon
CAS: 7440-37-1
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The substance must be handled in accordance with good industrial hygiene and safety procedures. Only experienced and properly instructed persons should handle gases under pressure. Consider pressure relief device(s) in gas installations. Ensure the complete gas system was (or is regularly) checked for leaks before use. Do not smoke while handling product. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Do not breathe gas. Avoid release of product into atmosphere. Refer to supplier's container handling instructions. Do not allow backfeed into the container. Protect cylinders from physical damage; do not drag, roll, slide or drop. When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Leave valve protection caps in place until the container has been secured against either a wall or bench or placed in a container stand and is ready for use. If user experiences any difficulty operating cylinder valve discontinue use and contact supplier. Never attempt to repair or modify container valves or safety relief devices. Damaged valves should be reported immediately to the supplier. Keep container valve outlets clean and free from contaminants particularly oil and water. Replace valve outlet caps or plugs and container caps where supplied as soon as container is disconnected from equipment. Close container valve after each use and when empty, even if still connected to equipment. Never attempt to transfer gases from one cylinder/container to another. Never use direct flame or electrical heating devices to raise the pressure of a container. Do not remove or deface labels provided by the supplier for the identification of the cylinder contents. Suck back of water into the container must be prevented.
Keep container below 50°C in a well ventilated place. Store containers in location free from fire risk and away from sources of heat and ignition. Containers should be stored in the vertical position and properly secured to prevent them from falling over.
The substance must be handled in accordance with good industrial hygiene and safety procedures. Do not smoke while handling product. Do not breathe gas.
Do not smoke while handling product. Never use direct flame or electrical heating devices to raise the pressure of a container.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate general and local exhaust ventilation. Systems under pressure should be regularly checked for leakages. Oxygen detectors should be used when asphyxiating gases may be released. Consider work permit system e.g. for maintenance activities.
Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risk.
Wear safety glasses with side shields. Standard EN 166 - Personal eye-protection.
Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask.
Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
None necessary.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No reactivity hazard other than the effects described in sub-sections below.
None.
None under recommended storage and handling conditions (see section 7).
None. For additional information on compatibility refer to ISO 11114.
None.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1046
- Shipping Name
- HELIUM, COMPRESSED
- Transport Class
- 2.2
- Packing Group
- Not applicable
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure cylinder valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure cylinder valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure cylinder valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Helium?
The signal word is warning.
What is the physical form of Helium?
Helium is a gas with colourless color. It has no odour warning properties odor.
What is Helium used for?
Industrial and professional. Perform risk assessment prior to use. Test gas/Calibration gas. Purge gas, diluting gas, inerting gas. Purging. Laboratory use. Use for manufacture of electronic/photovoltaic components. Shield gas for welding processes. Contact supplier for more information on uses.
What are the hazard statements for Helium?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of Helium?
The melting point is -272 °C and the boiling point is -269 °C.