NextSDS Logo
Safety Data Sheet EN

opta 2000

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
opta 2000

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Metalworking

Manufacturers & Suppliers

S

SOTEBASA

manufacturer

RUE BUISSON AUX LOUPS 5, B - 1400 NIVELLES

3267 493 143

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Preparation of: Mineral oil, sulphur compounds, corrosion inhibitors, friction and abrasion preventing additives.

Chemical Name CAS Number Concentration Hazardous
ZnDTP EC: 288-917-4 85940-28-9 3% Yes
N/A --- 1% Yes

When used and handled according to specifications, the product does not have any harmful effects according to our experience and the information provided to us.

Notes

When used and handled according to specifications, the product does not have any harmful effects according to our experience and the Information provided to us.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Ensure of fresh air. (eventually by inhaling the overheated product)

Skin contact

In case of contact with skin wash off with soap and water.

Eye contact

In case of contact with eyes rinsing with plenty of lukewarm water carefully and seek for medical treatment.

Ingestion

Do not induce vomiting. Refer to medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, Dry powder, carbon dioxide, sand, water mist

Unsuitable media

Full water jet

Specific hazards

In the event of fire the following can be released: Nitrogen oxides (NOx), Carbon monoxide (CO), Sulphur dioxide (SO2)

Instructions

Cool endangered containers with water spray jet.

Firefighter Protection

Use breathing apparatus with independent air supply (isolated). Do not inhale explosion and/or combustion gases.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

High risk of slipping due to leakage/spillage of product.

Environmental

Do not discharge into the drains/surface waters/groundwater. Do not discharge into the subsoil/soil.

Cleanup methods

Take up with absorbent material (e.g. oil binder).

Materials: absorbent material (e.g. oil binder)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures necessary if used correctly.

Storage

Keep containers tightly closed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

or handcream. Choosing a suitable glove is not only dependent on the material but also on further quality characteristics which are different from producer to producer. Therefore the resistance has to be checked before use.

Eyes

Wear face visor or goggles in circumstances where eye contact can accidentally occur.

Skin/Body

Working clothes

Environmental

Local regulations concerning handling and storage of waterpolluting products have to be followed.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Metal Corrosion
---
Solubility
---
Odor
product-specific
Decomposition Temperature
---
Flammability
---
Colour
(ASTM)1,5
Physical State Data
liquid
Evaporation Rate
---
State Under Standard Conditions
---
Melting Point
---
Colour Intensity
---
Freezing Point
---
Bulk Density
---
Ph
---
Flash Point
200 °C
Solubility In Water
Insoluble
Explosive Limits
---
Physical State
liquid
Upper Explosive Limit
6,5 %
Appearance
---
Vapor Pressure
---
Vapor Density
---
Cloud Point
---
Dynamic Viscosity
---
Auto Ignition Temperature
Product is not selfigniting.
Partition Coefficient
---
Voc Content
---
Molecular Weight
---
Properties Status
---
Form
liquid
Boiling Point
---
Relative Density
---
Odor Threshold
---
Relative Evaporation Rate
---
Softening Point
---
Density
0,888 g/cm³
Crystallisation Point
---
Kinematic Viscosity
25 mm²/s
Solidification Point
---
Solubility In Fat
---
Lower Explosive Limit
0,6 %
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Reactivity

Reactions with strong oxidising agents.

Incompatible

Reactions with strong acids and oxidizing agents.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Delivery only to officially authorized collectors.

Disposal

Where possible, arrange for product to be recycled. Delivery only to officially authorized collectors.

Waste Codes

12 01 07 mineral-based machining oils free of halogens (except emulsions and solutions) EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for opta 2000?

The signal word is no signal word.

What is the physical form of opta 2000?

opta 2000 is a liquid with (astm)1,5 color. It has product-specific odor.

What is opta 2000 used for?

Metalworking