NextSDS Logo
Py

Pyrocast Mortar FS980

NO SIGNAL WORD Solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Pyrocast Mortar FS980
Product Form
non-cast powder or granular material, or a mastic or moldable material
Product Code
02106 - PCM980

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Dry component of refractory mortar.
Uses Advised Against
Not fit for use in anything related to human consumption.

Overview

Pyrocast Mortar FS980 is a granular substance commonly used dry component of refractory mortar..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Pyrotek Engineering Materials Ltd.

manufacturer

๐Ÿ“

Garamonde Drive Wymbush, Milton Keynes MK8 8LN UK

๐ŸŒ

GB

๐Ÿ“ž

+44 (0) 1908 561155

๐Ÿ“ 

+44 (0) 1908 560473

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemtrec North America

๐Ÿ“ž

(800) 424-9300

๐ŸŒ

US

Chemtrec Outside North America

๐Ÿ“ž

+1 703 527 3887

๐ŸŒ

US

Emergency Contact

๐Ÿ“ž

112

๐Ÿ’ก

General European emergency number

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Silica, Non-Crystalline Fused
EC: 262-373-8
60676-86-0 95-95% โœ“ Non-hazardous
Aluminum Oxide
EC: 215-691-6
1344-28-1 1-10% โœ“ Non-hazardous

Composition Notes

For the full text of the R phrases mentioned in this Section, see Section 16 For the full text of the H-Statements mentioned in this Section, see Section 16

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. Get person to drink water to clear throat and blow nose to evacuate dust and fibers. If symptoms persist, call a doctor.

๐Ÿ–๏ธ Skin Contact

Wash off with soap and water. Treat irritated or desiccated skin with hydrating skin cream. If skin irritation persists, call a doctor.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If symptoms persist, call a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Not a normal route of exposure. Consult a doctor if necessary.

๐Ÿšจ Immediate Medical Attention Required

If symptoms persist, call a doctor. If skin irritation persists, call a doctor. Consult a doctor if necessary.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
granular
๐ŸŽจ Colour
White Grey brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
granular
๐Ÿ‘ƒ Odor
No odor
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not applicable
๐ŸงŠ Melting Point
1538 C / 2800 F
Critical Property
๐Ÿ’จ Boiling Point
Not applicable
Critical Property
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
1538 C / 2800 F
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not applicable
๐Ÿ“Š Vapor Density
Not applicable
๐Ÿ“Š Relative Density
2.5 - 3.5 g/cc
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
2.5 - 3.5 g/cc
Critical Property
๐Ÿ”ฅ Flammability
Not applicable
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
< 3%
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
VOC free
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not measured
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure adequate ventilation, especially in confined areas.

๐Ÿงค Hand Protection

Protective gloves.

๐Ÿ‘๏ธ Eye Protection

Tightly fitting safety goggles.

๐Ÿ˜ท Respiratory Protection

Respirator must be worn if exposed to dust, When workers are facing concentrations above the exposure limit they must use appropriate certified respirators, EN14387 approved respirator.

๐Ÿฆบ Skin/Body Protection

Long sleeved clothing, Protective clothing as (when) required.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Pyrocast Mortar FS980?

The signal word for this substance is "no signal word".

What is the physical form of Pyrocast Mortar FS980?

Pyrocast Mortar FS980 is a solid appearing as granular with white grey brown color. It has no odor odor.

What is Pyrocast Mortar FS980 used for?

Dry component of refractory mortar.

What is the melting point of Pyrocast Mortar FS980?

The melting point is 1538 C / 2800 F and the boiling point is Not applicable.