Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Pyrocast Mortar FS980
- Product Form
- Dry component that works together with a liquid activator to complete a two-part refractory formula. This MSDS supports the product as a non-cast powder or granular material, or a mastic or moldable material.
- Product Code
- 02106 - PCM980
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Dry component of refractory mortar.
Uses advised against
Not fit for use in anything related to human consumption.
Manufacturers & Suppliers
Pyrotek Engineering Materials Ltd.
manufacturer
Garamonde Drive Wymbush, Milton Keynes MK8 8LN UK
+44 (0) 1908 561155
Emergency Contacts
Chemtrec North America
(800) 424-9300
Chemtrec Outside North America
+1 703 527 3887
Europe
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silica, Non-Crystalline - Fused EC: 262-373-8 | 60676-86-0 | 95% | No |
| Aluminum Oxide EC: 215-691-6 | 1344-28-1 | 1 - 10% | No |
Notes
For the full text of the R phrases mentioned in this Section, see Section 16 For the full text of the H-Statements mentioned in this Section, see Section 16
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get person to drink water to clear throat and blow nose to evacuate dust and fibers. If symptoms persist, call a doctor.
Wash off with soap and water. Treat irritated or desiccated skin with hydrating skin cream. If skin irritation persists, call a doctor.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If symptoms persist, call a doctor.
Not a normal route of exposure. Consult a doctor if necessary.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding fire
None known.
None known.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid dust formation. Use personal protective equipment.
Do not allow to be wind blown.
Sweep up or vacuum up spillage and collect in suitable container for disposal. Soak up with inert absorbent material.
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure adequate ventilation.
Keep container tightly closed in a dry and well-ventilated place. Protect against water and moisture.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Protective gloves.
Tightly fitting safety goggles.
Respirator must be worn if exposed to dust, When workers are facing concentrations above the exposure limit they must use appropriate certified respirators, EN14387 approved respirator.
Long sleeved clothing, Protective clothing as (when) required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Stable.
Hazardous polymerisation does not occur.
Avoid dust formation.
Non-reactive, chemicaly inert.
No dangerous reaction known under conditions of normal use.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Can be landfilled or incinerated, when in compliance with local regulations.
Can be landfilled or incinerated, when in compliance with local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Pyrocast Mortar FS980?
The signal word is no signal word.
What is the physical form of Pyrocast Mortar FS980?
Pyrocast Mortar FS980 is a solid appearing as granular with white grey brown color. It has no odor odor.
What is Pyrocast Mortar FS980 used for?
Dry component of refractory mortar.
What is the melting point of Pyrocast Mortar FS980?
The melting point is 1538 °C / 2800 °F and the boiling point is Not applicable.