NextSDS Logo
Safety Data Sheet EN

Pyrocast Mortar FS980

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Pyrocast Mortar FS980
Product Form
Dry component that works together with a liquid activator to complete a two-part refractory formula. This MSDS supports the product as a non-cast powder or granular material, or a mastic or moldable material.
Product Code
02106 - PCM980

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Dry component of refractory mortar.

Uses advised against

Not fit for use in anything related to human consumption.

Manufacturers & Suppliers

P

Pyrotek Engineering Materials Ltd.

manufacturer

Garamonde Drive Wymbush, Milton Keynes MK8 8LN UK

+44 (0) 1908 561155

Emergency Contacts

Chemtrec North America

(800) 424-9300

Chemtrec Outside North America

+1 703 527 3887

Europe

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Silica, Non-Crystalline - Fused EC: 262-373-8 60676-86-0 95% No
Aluminum Oxide EC: 215-691-6 1344-28-1 1 - 10% No

Notes

For the full text of the R phrases mentioned in this Section, see Section 16 For the full text of the H-Statements mentioned in this Section, see Section 16

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Get person to drink water to clear throat and blow nose to evacuate dust and fibers. If symptoms persist, call a doctor.

Skin contact

Wash off with soap and water. Treat irritated or desiccated skin with hydrating skin cream. If skin irritation persists, call a doctor.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If symptoms persist, call a doctor.

Ingestion

Not a normal route of exposure. Consult a doctor if necessary.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding fire

Unsuitable media

None known.

Specific hazards

None known.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid dust formation. Use personal protective equipment.

Environmental

Do not allow to be wind blown.

Cleanup methods

Sweep up or vacuum up spillage and collect in suitable container for disposal. Soak up with inert absorbent material.

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure adequate ventilation.

Storage

Keep container tightly closed in a dry and well-ventilated place. Protect against water and moisture.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas.

Hands

Protective gloves.

Eyes

Tightly fitting safety goggles.

Respiratory

Respirator must be worn if exposed to dust, When workers are facing concentrations above the exposure limit they must use appropriate certified respirators, EN14387 approved respirator.

Skin/Body

Long sleeved clothing, Protective clothing as (when) required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Voc Content
VOC free
Explosive Limits
---
Odor Threshold
---
Melting Point
1538 °C / 2800 °F
Flash Point
---
Cloud Point
---
Colour
White Grey brown
Density
2.5 - 3.5 g/cc
Auto Ignition Temperature
---
Boiling Point
Not applicable
Partition Coefficient
---
Bulk Density
---
Relative Density
2.5 - 3.5 g/cc
Physical State
Solid
Vapor Pressure
Not applicable
Relative Evaporation Rate
---
Upper Explosive Limit
---
Kinematic Viscosity
Not measured
Appearance
granular
Properties Status
---
Freezing Point
1538 C / 2800 F
Form
granular
Molecular Weight
---
Solidification Point
---
Lower Explosive Limit
---
Solubility
---
Solubility In Water
< 3%
Odor
No odor
Flammability
Not applicable
Ph
Not applicable
Decomposition Temperature
---
Crystallisation Point
---
Softening Point
---
Vapor Density
Not applicable
Physical State Data
solid
State Under Standard Conditions
---
Evaporation Rate
---
Metal Corrosion
---
Colour Intensity
---
Dynamic Viscosity
---
Solubility In Fat
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Stable.

Hazardous reactions

Hazardous polymerisation does not occur.

Avoid

Avoid dust formation.

Incompatible

Non-reactive, chemicaly inert.

Decomposition

No dangerous reaction known under conditions of normal use.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Can be landfilled or incinerated, when in compliance with local regulations.

Disposal

Can be landfilled or incinerated, when in compliance with local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Pyrocast Mortar FS980?

The signal word is no signal word.

What is the physical form of Pyrocast Mortar FS980?

Pyrocast Mortar FS980 is a solid appearing as granular with white grey brown color. It has no odor odor.

What is Pyrocast Mortar FS980 used for?

Dry component of refractory mortar.

What is the melting point of Pyrocast Mortar FS980?

The melting point is 1538 °C / 2800 °F and the boiling point is Not applicable.