Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Flucon 150 AI
- Product Form
- Refractory castable
- Chemical Name
- Alumino-silicate
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial refractory application
Uses advised against
No information available
Manufacturers & Suppliers
Gouda Refractories
manufacturer
Goudkade 16, 2802 AA Gouda, The Netherlands
+31(0)182591400
Emergency Contacts
Gouda Refractories
+31 (0)1825 91400
8.00- 17.00 h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Aluminum silicate (calcined) | 1327-43-1 | 50% | No |
| Alumina cement | 65997-16-2 | 25% | No |
| Amorphous silica | 7631-86-9 | 10% | No |
| Aluminum oxide | 1344-28-1 | 25% | No |
| Barium sulfate | 7727-43-7 | 10% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh and dust free area
Wash skin with soap and water. Get medical attention if symptoms occur.
Dust should be flushed with clean water. Contact lenses should not be worn with dust in the air IF IN EYES: Rinse cautiously with water for several minutes. Continue rinsing.
Rinse mouth. Not a normal way of entry. Drink large quantities of water and consult a doctor.
Immediate Medical Attention
Get medical attention if symptoms occur. Consult a doctor if ingested. If symptoms persist, call a physician.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product itself does not burn. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
No information available.
None in particular.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No special environmental precautions required.
Shovel or sweep up.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Provide appropriate exhaust ventilation at places where dust is formed. Prevent dust formation and ensure adequate ventilation/dust extraction.
Keep in a dry place.
Handle in accordance with good industrial hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. If user operations generate dust, fumes or mist, use ventilation to keep exposure to airborne contaminants below the exposure limits.
No special protective equipment required. Protective gloves are recommended.
Safety glasses with side-shields or goggles to prevent dust and particles from entering the eyes.
When workers are facing concentrations above the exposure limit (dust) they must use appropriate certified respirators.
No special protective equipment required.
Avoid dust formation
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions
None under normal processing
None under normal processing
None under normal processing; Moisture; may cause lumps
None under normal processing
None under normal processing
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Material can be recycled or disposed according to local regulations
Material can be recycled or disposed according to local regulations
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated.
- Shipping Name
- Not regulated.
- Transport Class
- Not regulated.
- Packing Group
- Not regulated.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Flucon 150 AI?
The signal word is no signal word.
What is the physical form of Flucon 150 AI?
Flucon 150 AI is a dry, grey powder appearing as dry, grey powder, no odor with grey color. It has no odor odor.
What is Flucon 150 AI used for?
Industrial refractory application
What is the melting point of Flucon 150 AI?
The melting point is >1650 [°C] and the boiling point is Not determine.