Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DIFENOCONAZOLE TECHNICAL
- Product Code
- CGA169374A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Fungicide, Active substance for use in plant protection products
Manufacturers & Suppliers
Syngenta Crop Protection AG
manufacturer
Rosentalstrasse 67, Postfach, CH-4002 Basel, Switzerland
+41 61 323 11 11
Emergency Contacts
Emergency Contact
+44 1484 538444
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| difenoconazole (ISO) | 119446-68-3 | 90 - 100% | Yes |
| toluene EC: 203-625-9 | 108-88-3 | 0.25 - 1% | Yes |
| n-heptane EC: 205-563-8 | 142-82-5 | 0.1 - 0.25% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Take the victim into fresh air. If breathing is irregular or stopped, administer artificial respiration. Keep patient warm and at rest. Call a physician or poison control center immediately.
Symptoms: Aspiration may cause pulmonary edema and pneumonitis.
Take off all contaminated clothing immediately. Wash off immediately with plenty of water. If skin irritation persists, call a physician. Wash contaminated clothing before re-use.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses. Immediate medical attention is required.
Symptoms: Causes serious eye irritation.
If swallowed, seek medical advice immediately and show this container or label. Do not induce vomiting: contains petroleum distillates and/or aromatic solvents.
Symptoms: Harmful if swallowed.
Immediate Medical Attention
Call a physician or poison control center immediately. Immediate medical attention is required. If swallowed, seek medical advice immediately and show this container or label.
Medical Treatment
There is no specific antidote available. Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Extinguishing media - small fires. Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Extinguishing media - large fires: Alcohol-resistant foam or Water spray
Do not use a solid water stream as it may scatter and spread fire.
Fire will spread by burning with a visible flame. As the product contains combustible organic ingredients, fire will produce dense black smoke containing hazardous products of combustion (see section 10). Exposure to decomposition products may be a hazard to health.
Cool closed containers exposed to fire with water spray.
Firefighter Protection
Wear full protective clothing and self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to protective measures listed in sections 7 and 8.
Do not flush into surface water or sanitary sewer system.
Pick up with an electrically protected vacuum cleaner or by wet-brushing and transfer to a container for disposal according to local regulations (see section 13). Clean contaminated surface thoroughly. Clean with detergents. Avoid solvents.
Materials: detergents
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. When using do not eat, drink or smoke. Personnel handling this material and all conducting equipment should be electrically earthed or grounded. Consideration should be given to avoiding the use of insulating plastics.
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep out of the reach of children.
When using do not eat, drink or smoke. Avoid contact with skin and eyes.
Flames, hot surfaces, mechanical sparks and electrostatic discharges can serve as ignition sources for this material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Containment and/or segregation is the most reliable technical protection measure if exposure cannot be eliminated. The extent of these protection measures depends on the actual risks in use. Maintain air concentrations below occupational exposure standards. Where necessary, seek additional occupational hygiene advice.
Material: Nitrile rubber. Break through time: > 480 min. Glove thickness: 0.5 mm. Remarks: Wear protective gloves. The choice of an appropriate glove does not only depend on its material but also on other quality features and is different from one producer to the other. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The break through time depends amongst other things from the material, the thickness and the type of glove and therefore has to be measured for each case. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Tightly fitting safety goggles. Always wear eye protection when the potential for inadvertent eye contact with the product cannot be excluded. Equipment should conform to EN 166
No personal respiratory protective equipment normally required. When workers are facing concentrations above the exposure limit they must use appropriate certified respirators.
Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place. Remove and wash contaminated clothing before re-use. Wear as appropriate: Dust impervious protective suit
Water : Do not flush into surface water or sanitary sewer system. If the product contaminates rivers and lakes or drains inform respective authorities.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None reasonably foreseeable.
No dangerous reaction known under conditions of normal use.
No decomposition if used as directed.
None known.
No hazardous decomposition products are known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
12.5 Results of PBT and vPvB assessment
The substance is assessed as not PBT and not vPvB.
12.5 Results of PBT and vPvB assessment
The substance is assessed as not PBT and not vPvB.
12.6 Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
12.6 Endocrine disrupting properties
Substance does not have endocrine disrupting properties.
12.7 Other adverse effects
12.7 Other adverse effects
The substance is assessed as not persistent, mobile, and toxic (PMT) and not very persistent and very mobile (vPvM).
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Where possible recycling is preferred to disposal or incineration. It must undergo special treatment, e.g. at suitable disposal site, to comply with local regulations.
Where possible recycling is preferred to disposal or incineration. It must undergo special treatment, e.g. at suitable disposal site, to comply with local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3077
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S. (DIFENOCONAZOLE)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DIFENOCONAZOLE TECHNICAL?
The signal word is warning.
What is the physical form of DIFENOCONAZOLE TECHNICAL?
DIFENOCONAZOLE TECHNICAL is a powder with white to light brown color. It has sweetish, weak odor.
What is the solubility of DIFENOCONAZOLE TECHNICAL?
330 g/l(25 °C) Solvent: ethanol; > 500 g/l(25 °C) Solvent: methanol; > 500 g/l(25 °C) Solvent: Acetone; > 500 g/l(25 °C) Solvent: dichloromethane; 3.0 g/l(25 °C) Solvent: hexane; 110 g/l(25 °C) Solvent: n-octanol; > 500 g/l(25 °C) Solvent: toluene; > 500 g/l(25 °C) Solvent: ethyl acetate
What is DIFENOCONAZOLE TECHNICAL used for?
Fungicide, Active substance for use in plant protection products
What are the hazard statements for DIFENOCONAZOLE TECHNICAL?
This substance has 4 hazard statements:
- H302: Harmful if swallowed.
- H319: Causes serious eye irritation.
- H351: Suspected of causing cancer.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of DIFENOCONAZOLE TECHNICAL?
The melting point is 82.0 - 83.0 °C and the boiling point is 220 °C (0.04 hPa).