Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur.
- Product Code
- 20104
- Chemical Name
- Acetic acid glacial
- Synonyms
- Ethanoic acid
Regulatory Identifiers
- CAS Number
- 64-19-7 Check regulations →
- REACH No.
- 01-2119475328-30-XXXX
Identified Uses
General chemical reagent
Manufacturers & Suppliers
VWR International Ltd.
distributor
Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN
0800 22 33 44
Emergency Contacts
CareChem24
+44 (0) 1270 502894
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Acetic acid | 64-19-7 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately call a POISON CENTRE/doctor. Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration.
After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately. Immediate medical treatment required because corrosive injuries that are not treated are hard to cure.
In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Protect uninjured eye. Remove contact lenses, if present and easy to do. Continue rinsing.
Immediately call a POISON CENTRE/doctor. Do NOT induce vomiting. Rinse mouth thoroughly with water. Give nothing to eat or drink.
Immediate Medical Attention
Immediate medical treatment required because corrosive injuries that are not treated are hard to cure.
Medical Treatment
Immediate medical treatment required because corrosive injuries that are not treated are hard to cure.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, ABC-powder, Carbon dioxide (CO2), Nitrogen
no restriction
In case of fire may be liberated: Carbon monoxide, Carbon dioxide (CO2)
DO NOT fight fire when fire reaches explosives. Use water spray jet to protect personnel and to cool endangered containers. In case of fire: Evacuate area.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
In case of major fire and large quantities: Remove persons to safety.
Discharge into the environment must be avoided.
Clear spills immediately.
Related Products
Similar products with comparable safety profiles
Acetic acid (glacial) 100% anhydrous for analysis EMSURE® ACS,ISO,Reag. Ph Eur
---
Acetic acid (glacial) 100% anhydrous for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-19-7
Acetic acid glacial
CAS: 64-19-7
Ammonium acetate AnalaR NORMAPUR® Reag. Ph.Eur., ACS
CAS: 631-61-8
Acetic acid, glacial
CAS: 64-19-7
Acetic acid glacial TECHNICAL
CAS: 64-19-7
Acetic acid glacial 99.85% (Food/Pharma Grade)
CAS: 64-19-7
Acetic acid (glacial) 100% EMPROVE® EXPERT Ph Eur,BP,JP,USP
CAS: 64-19-7
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
All work processes must always be designed so that the following is as low as possible: Inhalation, skin contact, Eye contact. Keep away from sources of ignition - No smoking. Usual measures for fire prevention. Take precautionary measures against static discharges. Protect from moisture.
Recommended storage temperature: 15-25°C. Keep container tightly closed and in a well-ventilated place. Keep/Store away from combustible materials.
Keep away from sources of ignition - No smoking. Usual measures for fire prevention. Take precautionary measures against static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms EN ISO 374. In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact: Suitable material: CR (polychloroprene, chloroprene rubber), Thickness of the glove material: 0,13 mm, Breakthrough time: 17 min, Recommended glove articles: VWR 112-0032. By long-term hand contact: Suitable material: CR (polychloroprene, chloroprene rubber), Thickness of the glove material: -, Breakthrough time: > 480 min, Recommended glove articles: VWR 112-2157
Eye glasses with side protection DIN-/EN-Norms: DIN EN 166. Recommendation: VWR 111-0432
Respiratory protection necessary at: aerosol or mist formation. Suitable respiratory protection apparatus: Full-/half-/quarter-face masks (DIN EN 136/140). Recommendation: VWR 111-0206. Suitable material: ABEK2P3. Recommendation: VWR 111-0059
Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
no data available
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
no data available
no data available
no data available
no data available
no data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose according to local legislation. Consult the appropriate local waste disposal expert about waste disposal.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2789
- Shipping Name
- ACETIC ACID, GLACIAL
- Transport Class
- 8 (3)
- Packing Group
- II
Passage forbidden through tunnels of category D when carried in bulk or in tanks. Passage forbidden through tunnels of category E.
Segregation group: 1
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur. known by?
Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur. is also known as: Ethanoic acid
What is the hazard signal word for Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur.?
The signal word is danger.
What is the physical form of Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur.?
Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur. is a liquid appearing as colourless with colourless color. It has no data available odor.
What is Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur. used for?
General chemical reagent
What are the hazard statements for Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur.?
This substance has 2 hazard statements:
- H226: Flammable liquid and vapour.
- H314: Causes severe skin burns and eye damage.
What is the melting point of Acetic acid glacial AnalaR NORMAPUR® ACS, Reag. Ph. Eur.?
The melting point is 17 °C and the boiling point is 118 °C (1013 hPa).